Models > 10651135610 > Instructions

10651135610 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 10651135610
61 - 75 of 200
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Mark from WEST PALM BCH, FL
Parts Used:
W10873791
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Icemaker not making ice
Simple to replace. 6 screws out. Unplug connections... Plug back in, replace screws.

Unfortunately still not making ice. Will try fill valve replacement.
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from MURFREESBORO, TN
Parts Used:
WPW10515057
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Used a flat head screwdriver to pop the old light out.
Plugged the new one in and snapped it into place. Only other need is a lantern or someone to shine a flashlight over your shoulder since the old light is, presumably, out.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jessica from WILLIAMSBURG, VA
Parts Used:
WPW10225581
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Part went bad the freezer was freezing up and refrigerator not getting cold
I pulled off the panel covering the part in the freezer cut and stripped the wires. Used crimper and connectors put the new part on put the wires band panel back on and plugged the refrigerator back in. Everything works just fine now.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jay from WOODWAY, TX
Parts Used:
W10873791
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Not making ice
First turn off the ice maker. Then there's four screws in the very back you remove pull out the cover. There's hex head 516 bolts maybe quarter inch that hold in the ice maker unplug the ice maker reverse process
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roger from BOULDER, CO
Parts Used:
W10873791
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice cube tray had a loose part hanging down
Did my homework.
Consulted Utube
Bought the part
Installed
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from WEST JORDAN, UT
Parts Used:
WPW10238100
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Valve leaking water
Unhooked water line from house to fridge then unbolted valve from fridge body then removed plastic water line from fridge to valve by pushing in on pex release tab then reversed process with new valve. Works like a charm. No more leakage. Wood floor is dry and Happy!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Del from LAS VEGAS, NV
Parts Used:
W11035841
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Ice maker doesn't function
The wire bundle under the left lower corner has 8 wires of which 5 were chaffed and broken due to operation of the door and poor design. Remove the kick panel to expose the bundle, remove hardware holding the bundle to allow room to strip and splice the wires. Ice maker works fine now.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Elizabeth from EDENTON, NC
Parts Used:
W10873791
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
My ice maker would only freeze for a short while, after unplugging it for a few hours it would begin to make ice again only to stop after a few trays
The repair went great, however, I had someone to put the part in for me.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
rich from PEMBROKE PNES, FL
Parts Used:
WPW10225581
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Top half of freezer & fridge were not cooling. Freezer fan had been making unusually loud noises.
Piece of cake. It took me longer to remove the food from the freezer, remove shelves and back panel than to do the repair. I heard the fan making some noises so I replaced both the fan and defrost thermostat. I used the instructions submitted by a another customer. My 20+ year old fridge is like new now.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from STATEN ISLAND, NY
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Freezer work perfectly, Refrigerator Stopped getting cold, water line froze, there was ice Forming around the condenser in the bottom of the refrigerator behind the drawers
Freezer worked great, refrigerator stopped getting cold and lots of ice formed around the condenser on the bottom of the refrigerator.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Camille from Glen Ellyn, IL
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Freezer was icing up and leaking. Refrigerator side would not keep cold.
We emptied out both sides, refrigerator and freezer, and followed the instructions in your video. We turned it off and disconnected the power. We took off the freezer door first. It made it much easier to get the shelves out and reach way back into the freezer. We removed the light and cover, then the ice auger motor. The back panel was easy to lift and remove. The wire assembly was a little hard to understand at first, but when we figured it out it was easy to remove and replace the bimetal defrost thermostat. We did check the video when we had the wire harness out, to make sure we got it right. We reassembled the freezer's inside parts and reattached the door. Before we turned the power back on, we scrubbed down the entire refrigerator. When we turned the power back on, the refrigerator and freezer were operating quietly - no sparks or explosions or shorting out - hooray! And the problems were solved.
The most important resource is your video. It looked like something we could do, and then ordered the parts. Our repair took a long time because we checked the video so many times. Thank you so much for the great information and the excellent parts. We could not have done it without you.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
J. David from BRENTWOOD, TN
Parts Used:
WPW10350564
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Capacitor shorted out due to power surge.
Access back of unit, lower left corner. Remove wire capacitor retention clip. Unplug cold capacitor, plug in replacement, reinstall wire retention clip, test.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from ENDWELL, NY
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when you try and remove the cable assembly. Hope this is helpful.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10651135610