Models > 25370313214 > Instructions

25370313214 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 25370313214
16 - 19 of 19
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Cynthia from CIRCLEVILLE, OH
Parts Used:
241778811
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Flipper mullion assembly broke
Removed 1 screw and unplugged flipper mullion assembly and removed it. Plugged in new flipper and one screw and done. Works as it should.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from MAGNOLIA, AR
Parts Used:
241675704
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
ice maker is stuck on crushed ice.
We had someone to come and look at it and we were told it was the solenoid valve. The repairman unstuck it for us and said when it does it again, he would have to order the part. We took it upon ourselves to order the part and DIY. We replaced the part that we were told was the problem and "guess what" it's still not fixed. It's still shooting out crushed ice. Will have to call repair guy back out here to see what we did wrong.
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Debbie from Mount Juliet, TN
Parts Used:
5303918899
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer Cold, but Refrigerator not Cold
We replaced the damper, but it didn't fix the problem. We then purchased and replaced the thermistor. (We had previously replaced the defrost thermostat). The refrigerator side is now cooling better, but not enough. The damper doesn't seem to be opening. So we have now unplugged the damper and left the opening between the refrigerator propped open and the refrigerator side is now cool enough. (We had previously tried keeping the damper open before we replaced the thermistor and the refrigerator didn't cool off. So the thermistor did fix something, but the damper doesn't seem to have been the problem).
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JACK from OAK LAWN, IL
Parts Used:
242046001
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
unit was not cooling or freezing.
found the coil to be frozen like a block of ice. defrosted same, then looked up what defrost thermastat i needed and once it was received, i took the back of the freezer compartment off again, (two hex nuts, one on each end, and a small screwdriver to remove guard around fan. once this was removed, you then remove this panel, and you will see the evaperator coil, which will be frozen like a block of ice like i said. then remove defrost therm(small round piece with two wires connected to unit, disengage and re engage new thermostat. then put unit back!. no more freeze ups.also, therm was on top right of evaPERATOR. IT also snaps off on the bottom of thermastat. (just pull to or away from you and it should come off.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25370313214
16 - 19 of 19