- Customer:
- Carl from RIVERSIDE, CA
- Parts Used:
- 8009
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Arlington, TX
- Parts Used:
- 4387478
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Elyse from Skokie, IL
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Yafa (and David) from Bothell, WA
- Parts Used:
- 8009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ray from palm bay, FL
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Fridge stopped cooling
I replaced the defrost relay folling instructions I read on the internet--and it still didn't work--So I replaced the compressor start relay which was easier than the defrost relay--it worked and the fridg is working good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- LES from GRAY, TN
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Refrigerator coils froze up and 5 weeks later it got stuck in defrost.
The parts were reasonably priced, shipped promptly and received in a couple of days. I reviewed a YouTube video before starting that was beneficial. Huge savings over retail repair service. A+ replacement parts house and I would highly recommend.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from HOUSTON, TX
- Parts Used:
- 4387478
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Faulty light socket
Followed the video instructions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Suzanne from STERLING HTS, MI
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Refrigerator light would not turn on.
I first replaced the switch and had no results, I then ordered the Light Socket Kit, and because I had the experience of removing the panel to replace the switch, it took a few minutes to remove the two screws behind the panel, removing the temperature control knobs and then releasing the face plate which is secured by tabs at the bottom. The kit came with extra connectors in case they were needed, but they were not in my case and so I pulled off the wires, pushed the old socket out and the new one in. Attaching the wires to the correct pins, I screwed in the light bulb to be sure that the fix was correct and determining that, I replaced the screws that held the panel in place. Voila, I'm a happy camper who found some outdated jars in the back corners of the newly lighted shelves.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from McLoud, OK
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator was freezing up and not cooling fresh food compartment
The repair was easy, I removed the cover on the top front of the fresh food compartment. It housed the defrost timer which was easy to identify and replace. Just removed a screw, unplugged the wires and replaced with the new part. Unfortunately, that wasn't the only problem. I also had to replace the defrost element that the timer sent power to. While I was at it, I replaced the defroster thermostat. The entire repair took under an hour, diagnosing the problem took the most time and effort.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Victor from Colton, CA
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The refridgerator will not run
After the front panel was removed, disconnected the timer and installed new in reverse order. The provided instructions could be more straight forward, I spent more time reading it than the installation itself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cecelia from Garden City, TX
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer made lots of Ice and Refrigerator didn't cool
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator brand new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- MATTHEW from STOCKTON, CA
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The Light Socket Burned Out.
I pulled the socket out and unplugged the wires. I replaced the light socket by plugging in the wires and snapping the light socket into place. A very simple fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Fairfield Glade, TN
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer Cold - Refrigerator Warm
After searching online to diagnose the issue with my refrigerator being warm and the freezer being cold and not shutting off to defrost I decided to get the defrost timer kit. The kit arrived within 2 day. With the directions included, after unplugging the appliance for safety, I installed it relatively quickly with only a screwdriver . I then plugged it back in and it immediately went to defrost. I thought, wow I have it fixed. Well unbeknownst to me it still didn't cool in the fridge area. After doing more internet research I found a suggestion to unplug the fridge for 24 hours to unthaw ice that may be lodged between the freezer and fridge that is blocking the distribution of cold air into the fridge. After doing this, it now works like a charm.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- anthony from NORCROSS, GA
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer no longer frost free.
Reviewed Youtube video as a reference. Unplugged refrigerator. Removed old defrost timer. Matched the color of the wiring harness to the diagram that came with the part. Attach new part to wiring harness.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from REDDING, CA
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Warm refrigerater
Followed instructions from ideoo
Was this instruction helpful to you?
Thank you for voting!