- Customer:
- Monica from EDMOND, OK
- Parts Used:
- W10823511
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this instruction helpful to you?
Thank you for voting!
Noisy operation (from the inside)
Unplug, then on the freezer side, remove the drawers, then remove the screws holding the sheet metal cover, remove the rails (for the drawer) that interfere with removing the sheet metal cover. pull the wires off the motor. There is a big plastic piece that holds a small plastic piece that holds the motor. Remove the plastic piece that holds the motor/fan (you might be able to swap the motor by removing the little plastic piece that holds the motor, or you can remove the bigger piece and then remove the small piece that holds the motor). Pull the fan blade off (to reuse), swap the motor. NOTE - the new motor wire terminals may be on the opposite side of the motor vs. the old motor - that is not a problem - there is plenty of room for the wires. After the motor is installed put the fan blade back on, reinstall the removed plastic pieces in the back of the refrigerator. Now, I'd suggest a quick test. Make sure the new motor works and the fan blows before you button it up. Once you know it works, power it off, and put the sheet metal cover back on, reinstall the basket brackets, put the baskets back in place, close the door, and turn it back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from CONWAY SPGS, KS
- Parts Used:
- WPW10225581, WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
fridge and freezer stopped maintaining proper temp
I followed the repair videos that were provided by partselect and installed a bi-metal defrost thermostat in the freezer and a thermostat assembly in the fridge. The installation was not hard and everything is now working as it should. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Olympia, WA
- Parts Used:
- 4388538
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
The flat support part of the stud had broken off, and I had removed the part to try to find a replacement. So, the shelf that holds one of the drawershad no front support on one side.
I removed the drawer and the shelf. I looked at the support on the other side to figure out how to insert the new one. Due to the shape of the "hook" part of the support, and the hole it needed to go into, I figured out which way I needed to insert it to be able to twist it so it would stay in place. From another online hint, and from talking to a repairman at a local shop (who had ordered me the wrong part) I knew I needed to twist it after inserting it. I used a pair of pliers to twist it counterclockwise, about a 3/4 turn. I put the shelf in and re-installed the drawer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Roanoke, VA
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Ypsilanti, MI
- Parts Used:
- WP2155476
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
broken kickplate
just snapped it on,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Arlington, TX
- Parts Used:
- 4387478
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dana from Canyon Lake, TX
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Redmond, WA
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer was dripping water into refrigerator below
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Needed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Center Moriches, NY
- Parts Used:
- WP2315576
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Icemaker just stopped making ice one night
I pulled the refrigerator out from the wali slowly so not to damage the water line to the ice maker. Then with a nut driver I removed all the screws holding the back plate on. Being careful not to kink the water line, I used the adjustable wrench to losen the water line feed nut and the nut that goes to the line to the icemaker. Then I removed the screws holding the valve in place finished unhooking the water lines with my fingers. I then got the new valve and finger tightend the main water supply nut to the inlet side, then I pushed the plastic supply tube going to the icemaker into the valve. The new valve does not use a nut to attach the tubing it is a presure fit very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Olesya from ORLANDO, FL
- Parts Used:
- WP2198202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refregirator would not turn cooling back on after shutting down.
After spending $250 on repair by calling appliance repair professional who changed relay in the fridge, the problem was not solved. I had to manually turn the switch off and on again to make sure my fridge would maintain its temperature. I read some similar problems on this web site, watched instalation video and decided to give it a try. Part came in very quick and it took me (female) 45 minutes to install the new part and refregirator worked like a champ. I would never call professional again until I try fixing the problem myself.
Was this instruction helpful to you?
Thank you for voting!
The parts where incorrect
I received two Ice Maker kits and one was packaged wrong and the second was also wrong, I called the support staff and worked with them for over two hours before being told I could return the wrong parts for a full refund. After two / three weeks and a second call I received a email stating my refunds are being processed and I was charged shipping and return fee’s buyer beware!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vince from CERRO GORDO, IL
- Parts Used:
- WP2198202
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Fridge wouldn't turn on unless I hit the thermostat.
Removed old thermostat and replaced with new one. The video link in the shipping email was great - really detailed even though it was a simple fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Annapolis, MD
- Parts Used:
- W10190935
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
The icemaker in my freezer stopped producing ice
1. Removed the icemaker door
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Orangeburg, SC
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
3 inches of frost in Fridge, 72 degrees in Fridgerator
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Was this instruction helpful to you?
Thank you for voting!