Models > 1067690811 > Instructions

1067690811 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 1067690811
106 - 120 of 711
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Brad from RAINIER, OR
Parts Used:
WP819470
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
would shut off and not restart without tapping on knob
replaced the cold control thermostat . The new one was oriented 90 degrees off (on the bracket mount) so I had to turn it (in the bracket) to line up better with the wire connections and temp sensor tube. The power wires can be connected to either terminal however, and I suppose you could leave it as is if your wires can reach. Turning it will make the knob off 90 deg. off from original markings (off to coldest) but I simply remarked the position with a marker. (make sure you connect all terminals before mounting the bracket, it's much easier that way. .Note: this was a 40+ year old Sears "Coldspot" refridg. and it works like a dream since I changed out this original cold control. Love these old mechanical appliances that are much more reliable than the new brokered ones. Glad whirlpool has made many parts interchangeable through many years...kudos to them
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alvin from Sugar Land, TX
Parts Used:
WP4388152
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
the nozzle was broken
1. PUsh the Lock button so the water will not run.
2.Remove the screw holding the nozzle.
3. Remove the Grill
4. Disconnect the black water tube. Pull the female part of the union off the old tube and hold it for the new tube.
5. PUll it the tube out from the nozzle end.
6. Snake the new tube into the hole and shove it through until it comes out the door hinge port at the bottom of the door.
7. Continue pushing and pulling the tube until the nozzle is in position.
8.Test fit the new tube and cut a short piece off to fit properly.
9. Slide the female part of the union onto the new tube. Insert it onto the union and tighten.
10. Insert the screw that holds the nozzle in place and tighten.
11. Push the on unlock button and fill a glass with water.
12. Check for leaks. If no leaks reinstall the grill.
Job done.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Novi, MI
Parts Used:
4318046
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
The water in the door dispenser would run for several seconds and then start clunking. This resulted in no more water flow.
I guessed that the water dispenser solenoid was getting weak.
A quick web search led me to PartSelect's website where it was so easy to pull up my refrigerator model with diagrams. I ordered the valve kit, and in 5 days it was in my hands.

Installation was literally 10 minutes. It took longer than that to vacuum all the dust from under and in back of my refrigerator !
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
stephen from ROCKLEDGE, PA
Parts Used:
4317943
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
water was leaking under the frig ,wasnt sure what the problem
decided to take a chance and replace the ice maker,so far no water leaking.feels nice to know the problem is fixed.thanks for the video on how to replace it, thanks again very easy repair
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from San Diego, CA
Parts Used:
4317943
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker was leaking
This is an incredibly easy repair.

1) Remove the three screws holding the old icemaker

2) Disconnect the electrical connection (I used a spoon to get in and undo the connector clip

Do the opposite to install the new icemaker.

Total elapsed time was about 5 minutes.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dave from Manchester Center, VT
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raoul from Thousand Oaks, CA
Parts Used:
4317943
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ice maker not working
take out Ice maker tray, remove three screws holding the ice maker, unplug electrical connector. Replace with new Ice maker,Ice started to fill the tray. ENJOY!!
THANKS.
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MARGARITA from TAMPA, FL
Parts Used:
WP2256126
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Wrench (Adjustable), Wrench set
Dispensed water w/ funny looking particles
First the small screws you sent did not fit.I had to cut and mend the old ones (2) to use them.I did purchase a connecting valve tha I used to connect the part of tubing (my name for it) from old one to new one.I was surprides it is working fine.Not bad for a nurse!
10 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Long Valley, NJ
Parts Used:
4317943
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice Maker didn't produce ice cubes.
It was not complicated but it took more squeezing and reaching into the narrow space than actually removing three screws and unplugging the electrical harness. But that was all that was necessary, to install, three screws held the unit in place and re-connect the electrical harness. It saved me about $100 in labor and the inconvenience of scheduling a service call and waiting for a week or so. The best part was that I ordered the unit on line on Tuesday eveining and it was at my home by Friday afternoon with no extra shipping charges. Great service!.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Judy from Galveston, IN
Parts Used:
4317943
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker did not work
Took the old one out and plug the new one in, simply as 1 2 3. Order the part one morning,it was here the next afternoon, the ice maker was fixed in less than a half hour. we will order from you the next time.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from Chino, CA
Parts Used:
WP2196157
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Screw drivers
Filler tube broken and old tube frozen over
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matthew from Phoenix, AZ
Parts Used:
WP2196157
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Broken filler tube at threaded connection
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leanna from Tracy, CA
Parts Used:
WP4388152
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
the nozzle on the water spigot broke
we read on this site how to run the tube down thru the door but we had some problems. we used tape to put together the old and new hose to snake it down and the old hose pulled apart from the new and was stuck in the hole at the bottom of the door. my husband propped up the door and took the bottom hinge off to get to the hole where the tape was stuck and I was able to get a hold of it to finish pulling it through. I think we had to thick of tape wrapped around the two pieces.
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Corona, CA
Parts Used:
WPW10329686
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Broken Freezer Door Cams
1. Put pieces of wood under door to support it.
2. Unscrew three screws holding door hinge.
3. Disconnect water line.
4. Unscrew screw holding each cam. One to door and one to hinge.
5 Replace cams.
6. Retrieve plate with threaded holes behind frame that the hinge attaches to.
7. Use thin philips screwdriver through the hinge bracket, shim, frame and screw plate to align it for the other two screws.
8. Replace all three hinge screws.
9. Connect water line fitting.
10. Remove wood for door support.
11. Check door for smooth movement and strong pressure when closed.
3 of 3 people found this instruction helpful.