Jon from Boise, ID
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
No ice
1 screw remove assembly. Unplug cable harness and remove old cover and wire arm. Replace cover and wire arm and attach wire harness on assembly end. Re attach using screw removed in first step. Plug in wire harness. Making ice within 30 minutes.
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gary from carleton, MI
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
My icemaker started leaking water into the catch basin and turning my ice into one big ice burg.
Well folks I put up with an ice burg all summer when I really should have took the time to fix it. You know how it goes though. You get so busy you just put it off.
Well don't put this one off because this is just how easy it went.
I came home one evening and wanted to make a drink to relax but that big glob of ice was there waiting for me. I took a crewdriver and beat it down so I could pull the catch basin out. Having looked it over for a minute I grabed a nut driver and took three of the screws out that held it in. I unpluged the wire and bingo it was out. Maybe five min. had elasped.
After taking the unit out I notice how the non stick surface was coming off of the tray and that explains the black pieces that were getting into my ice.
Getting the model number off the back of the fridge and writing it down I went to my trusty lap top and did a quick search for a ice maker for my Jenn Air refrigeraton and blamo...! Part Select came up and I put the part number in their search engine and bingo again there it was, my part.
One quick order and in three days it was right there by my door when I got home.
Now i'm so excited. I went into the house and didn't even chage out of my dress clothes. Within five minutes it was in. Now I just had to wait for the timer to do it's thing and sure enough, I awoke the next morning to a whole tray of beautiful ice cubes. Wow no more ice burgs.
The moral of my story is I spent so much time hacking out that glob of ice and for fifteen minutes of my time, I could have been siping on cold ones by the pool but now old man winter is pressing down on me and I guess a lesson learned was a lesson earned. Fix it!
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Choctaw, OK
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Herndon, VA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharon from BRANFORD, CT
Parts Used:
67001019
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
No problem
Just snapped in new shelf
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Ruth, MI
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
My old icemaker lost some of the nonstick surface and the ice didn't want to come out
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Monroe, WA
Parts Used:
WP12555902
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Refrigerator and freezer was not cooling. The compressor would not stay running. When the compressor kicked on it would only run for a few seconds and got warm real quickly. I replaced both the overload relay combination and the running capacitor. Don't know what the problem is. I thought for sure t
disconnected wire connections, pulled old overload relay and running capacitor out like a plug and plug in the new one then reconnected the wires.
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ben from Falls Church, VA
Parts Used:
WP65889-4, WP12555902
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
No cooling in the freezer or in the refrigerator
Remover rear cover at bottom of refrigerator. The replacement run capacitor was the same as the original one. The replacement Overload Relay Combination was slightly different. It plugged onto the compressor the same, but the connector where the power came in from the wiring harness was different. I had to cut off the original connector from the wiring harness, and then splice in new connectors onto those two wires which I could then attach to the replacement Overload Relay Combination. Fortunately the connectors I needed were fairly common and I had those available. After that it worked. My suspicion is that the Run Capacitor was fine, and it was just the Overload Relay Combination that failed. Replacing the capacitor without replacing the Overload Relay Combination did not fix the problem.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from TAKOMA PARK, MD
Parts Used:
W11176463
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
The water supply line to the ice maker kept popping off after I replaced the water filter because an "ice plug" had formed in the fill tube, unbeknownst to me.
1. Turn your water OFF and pull the refrigerator out from the wall so you can access the back.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Monica from EDMOND, OK
Parts Used:
W10823511
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linford from Cedarville, NJ
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Icemaker would not fill with water.
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from Louisville, KY
Parts Used:
WP67001036
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
freezer was frosting up
Follow your parts diagram, I removed the nut screw from the light in the refrigerator. Removed the light cover. Removed the temperture control knob. Remove the damper control cover. Slid the light assembly forward. Pulled out old defrost timer, replaced with new one. reversed assembly order.
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dustin from Piedmont, OK
Parts Used:
12001937
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Back of freezer froze up and not getting cold in refrigertor.
I got on the web blog and saw a conversation on here that sounded just like the problems i have been having with my unit. After reading every thing about it i ordered the part needed and installed it. I let the fridge thaw out over night and started it up the next morning. Its been two month since i installed the part and it is working great!!!
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frederick from Hanover, MA
Parts Used:
WP67006506
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Power cord was cut
I removed the 5/16 inch hex head nuts holding the rear access panel where the power cord was connected. Once removed, I released the Molex plug and ground wire. I connected the new cord, screwed in the ground and installed the rear panel. Having the exact OEM part made the job quick and easy.
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Cupertino, CA
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The ice maker stopped making ice.
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?