1067623110 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Michael from Locust Grove, VA
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Making a god awful racket.
Ok its the garage "adult " Beverage chiller.
Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brad from RAINIER, OR
- Parts Used:
- WP819470
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
would shut off and not restart without tapping on knob
replaced the cold control thermostat . The new one was oriented 90 degrees off (on the bracket mount) so I had to turn it (in the bracket) to line up better with the wire connections and temp sensor tube. The power wires can be connected to either terminal however, and I suppose you could leave it as is if your wires can reach. Turning it will make the knob off 90 deg. off from original markings (off to coldest) but I simply remarked the position with a marker. (make sure you connect all terminals before mounting the bracket, it's much easier that way. .Note: this was a 40+ year old Sears "Coldspot" refridg. and it works like a dream since I changed out this original cold control. Love these old mechanical appliances that are much more reliable than the new brokered ones. Glad whirlpool has made many parts interchangeable through many years...kudos to them
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dale from Blaine, MN
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer making loud whining noise-Fridge not cooling well
Removed the 3 screws in the back of the freezer, pulled back the metal back plate on the freezer. Removed 4 nuts on the plastic housing that holds the fan and pulled the housing down. Disconnected the wires, unscrewed the 2 screws holding the fan to the housing. Replaced old fan motor with new fan motor onto housing just as it was before. Reconnected the wires. And tested the motor. Worked great. Re-assembled everything as it was and it was done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- allen from Dickson, TN
- Parts Used:
- WP819470
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
frig stopped running and everything ruined
The frig was already empty....removed the plastic control knobs and loosened the hex head screws to remove the cover . The wires were the same at each contact point, so, it took about 15 minuets to adjust the control knob to match the old one and reinstall the thermostat and place the cover...The other 15 minuets I spent finding my wife to show her the frig was back to work...Just a walk in the park...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ralph from SAINT PAUL, MO
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Evaporator Fan in Freezer Making Load Noise
Removed freezer shelving. Removed 3 shelving brackets (dovetailed) by sliding them up off of the small square mounted on the freezer wall. This was a stumbling block until
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TOM from GRANVILLE, MA
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
nosiy fan operation
most of the time spent on repair was removing the food from freezer compartment other than that removal of a couple screws and disconnecting and reconnecting wires not a huge ordeal
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from Chino, CA
- Parts Used:
- WP2196157
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Filler tube broken and old tube frozen over
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
doesn't that feel great?
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Clifton Heights, PA
- Parts Used:
- 482731
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Fan motor stopped working.
I first unplugged the unit.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Matthew from Phoenix, AZ
- Parts Used:
- WP2196157
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Broken filler tube at threaded connection
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jane from Albuquerque, NM
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from Ten Mile, TN
- Parts Used:
- WP2196157
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Installing old ice maker in new freezer
I was able to transfer my old ice maker from my old Roper Refrigerator/Freezer into my new Whirlpool Sidekick Freezer. Everything transferred directly except for the water fill tube. I ordered one on line and simply cut it to the right length, removed the cover plate inside the freezer compartment and the little sticker from the outside. Inserted tube and fastened in place with two screws (not provided but was able to use the screws that were in the holes inside the freezer before the ice maker went in. Works great. By not buying the ice maker with the freezer I saved a hundred bucks or so.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bonnie from DETROIT LAKES, MN
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Fan motor
Remove bottom of freezer by sliding out the gaskets on each side.
Remove back of freezer. 6 screws.
Remove fan cover. 4 screws.
Remove fan. 3 wires to disconnect. 2 screws to take out.
Install the fan. Connect the 3 wires. Fastened with 2 screws.
Put fan cover back on. 4 screws.
Put back of freezer back on. 6 screws.
Put bottom of freezer back in. Slide gaskets in on each side.
Remove back of freezer. 6 screws.
Remove fan cover. 4 screws.
Remove fan. 3 wires to disconnect. 2 screws to take out.
Install the fan. Connect the 3 wires. Fastened with 2 screws.
Put fan cover back on. 4 screws.
Put back of freezer back on. 6 screws.
Put bottom of freezer back in. Slide gaskets in on each side.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Winston A from Brooklyn, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JERRY from ALBION, AL
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
Fan was making alot of noise
I removed all the shelves and the back shelf hanger. Removed two screws on the back plate.Pulled it out.Removed the screws that hold the fan housing. Pulled it out so I could write down the three wires color and location.Unpluged them.Removed the old fan and installed the new one.and put everthing back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lloyd from Long Beach, CA
- Parts Used:
- 482731
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Noisy freezer evaporator fan motor
Removed the shelves from the freezer and the brackets holding it along with the covers for the light and plate for the ice maker (we don't have one). Pulled the ground wire from the tab off the port for the ice maker. Removed back plate exposing the fan motor and then the 4 hex screws holding on part #23 of the diagram which the fan motor is mounted to. Flipped it over, unscrewed the 2 hex screws from the fan motor mounting and removed it. Removed and replaced 3 wire connectors on new fan motor. Installed new fan motor and new grommets but used the old screws because the provided screws were larger. Pushed the new fan on to the motor shaft. Reassembled. Half hour most.
Was this instruction helpful to you?
Thank you for voting!