Models > 36358892890 > Instructions

36358892890 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 36358892890
61 - 75 of 635
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Alice from Cookson, OK
Parts Used:
WR02X11330, WR29X5171, WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice Maker overflows bucket and waterline leak
What can I tell you to help except if the 75+ year old Grandma can do it you can do it also. This site was great and the shipping was super fast.

Have put up with an ice maker that never automatically quit making ice for over a year. I just manually shut it off (remembered some of the time and was reminded by the error messages when overflowing at other times). I just didn't want to pay for a service call and all that involves for this item. Then the incoming waterline split and I had to make a decision and that was to DIY the repair after reading the info on this site. The ice maker was a breeze and you can read the details in other posts. Here I will say it takes removing two screws to loosen (mine wouldn't slip off unless screws were totally removed), (I shut off the water and unplugged refrigerator since I am neither an electrician nor an appliance repairman) unplugging the ice maker by removing one hex head, removing the control cover (bottom to top as described in other posts), remove 3 screws only in the metal plate that holds the inside of the ice maker together to get access to the "brains", replaced the Cam, reverse to reassemble (remembering to get the arm back into it's hole in the metal plate. End of that job.

After reading posts about the the water line tubing, I made sure that I had all of the parts of the correct size to replace all of the tubing that passes by the compressor. I did not, however, replace the full length of any of the tubing. I cut off the bad sections of the 1/4" to the middle of the back of the refrigerator and connected a new section with the 1/4" x 1/4" water tube unions.(I was able to buy 1/4" water line, 5/16" water line and 1/4" x 1/4" water tube unions locally but I could not find 5/16" x 5/16" water tube unions so I ordered them from PartSelect at the same time as I ordered the ice maker cam.)

Then I went to the inside of the refrigerator removed the cover from the water reservoir (behind the hydrator), cut out the old section of the water dispenser lines that pass by the compressor, threaded in (not as easy as the outside tubes but not difficult either) the new tubing and connected with the 5/16" x 5/16" water tube unions. You will get lots more details in other posts but this is to tell you that you CAN DO IT with help from this site! I fixed it all for less than $20 (versus cost of new refrigerator, or new ice maker, or service call).
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carl from Kent City, MI
Parts Used:
WR60X30349
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
refrigerator did not cool
i put a new evaporator motor in and now it works fine
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GEORGE from ELIOT, ME
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Will not make ice
Bing , Bang, Boom.
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Martinez, CA
Parts Used:
WR51X443
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Burnt out heater defront unit
1. Turned unit off and removed freezer shelving
2. Removed 5 screws on back pannel to expose heaters
3. Deforsted coils with a hair dryer and removed ice cubes
4. Compaired new defrost harness to the existing
5. Removed 4 screws holding the defective harness
6. Installed new heater harness with 4 screws and elec. plug
7. Reinstalled back pannel and shelving
8. Turned unit back on
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from The Woodlands, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andrew from Decatur, AL
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Top of refrigerator and freezer are warmer than bottom. Also, a large amoutnt of ice build up in the back of the freezer.
**Before you order a new part make sure you get the FULL model number off of the back of the refrigerator**
To even get to the back panel I had to melt the ice in the back of the freezer with a hair dryer. Once the ice was gone I removed 5 screws that held the panel that covers the coils. I melted more ice from the coils. I disconnected the connector for the old heater wiring harness and pooped the thermosat off. Then, removed the screws that held the heaters (2 per heater). Installed new heaters and connected wiring harness. Snapped new thermosat on. Replaced coil cover and plugged it back in.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Columbiana, AL
Parts Used:
WR9X489
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Quakertown, PA
Parts Used:
WR51X443
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
would not defrost
First I removed the light cover, one screw. Then I removed the rear coil cover, three Phillips screws and two hex head screws. I then defrosted the coils and removed the old defrost element and wiring harness, two hex head screws held in the element, wiring harness just unplugs. I the installed the new defrost coils ( new one had two coils but had a previously designed area for the second element ) and ran the wiring harness up to where the plug was. I then reinstalled the coil cover plate, and light guard and started the refridgerator. Frige runs like new. Thank you PartSelect for the extremely propmt delivery and the correct part. part
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Palmdale, CA
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer coil iceing up
removed freezer racks and back panel. removed and relaced defrosting harness. reassembled compartment
PartSelect rocks! easy to locate needed parts. price is fair and quick shipping. saved me $$$$
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Todd from Saint Paul, MN
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Noisy freezer evaporator fan, bearings worn out
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
D.H. from Mulberry, AL
Parts Used:
WR29X5153
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken gear
Removed old gear and tapped the replacement on.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Erie, PA
Parts Used:
WR60X225
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set, Wrench set
Unit wouldn't maintain a low temp.
Opened back,found fan not moving. Cleaned out dust and dirt. Received exact fan motor. Easiest fix I ever performed(very unusual). Fridge now runs great! Also, water line to in-door ice and water dry roughted and sprung leak. Replaced tubing.
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
H.K. from Seagoville, TX
Parts Used:
WR55X24065
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
compressor not starting
Refrigerator is not cooling. Light and fan working. Changed the capacitor.. Still not cooling. Back to discovery mode.It may be the timer
Certainly not PartSelect's fault. They have great service.
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hop from Houston, TX
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from Orange Park, FL
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
stopped making ice
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove from hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 36358892890