- Customer:
- anthony from georgetown, IL
- Parts Used:
- WP628356
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Broken Piece
Had to disassemble ice maker to install part. . .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from Lafayette, CO
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Fridge and freezer too warm
First it required defrosting since the cooling area was solid ice. Note that I replaced the defrost timer first and no difference. I pulled the icemaker and racks out, then removed the door by removing the 4 screws with 1/4" nut driver. One of the sliding drawer tracks must be removed in order to get the back panel in/ out easily. The 4 screws were easily removed with my nutdriver. The screws are not all the same so keep track! Next remove the 4 screws that hold in the vent assembly where the cold air shoots out (center). Remove all of the remaining screws in the panel in the rear of the freezer compartment and pull it out. The themostat is on the right side with 2 wires and a clip that holds it on to the coolant pipe. Pull it off of the pipe and locate the connector - 5-6" from the thermostat. Pull connector apart without damaging the wires inside. Install new part the same way the old one came out and reassemble in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Antonio from San Antonio, TX
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Choctaw, OK
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- R from Cranford, NJ
- Parts Used:
- W10752646
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Freezer cooling cycle became warmer
There was water on floor at front and ice cubes in freezer were wet.
Freezer cooling cycle had become warmer.
Received part. disassembled the temperature control; i.e., pulled off the control knob; removed 3 screws holding unit to top of freezer; pulled two wires from their connectors to the old "control unit"; pushed them onto the connections of the new unit; reassembled the control to the top of the freezer with the three screws and pushed on the control knob.
bybob
Freezer cooling cycle had become warmer.
Received part. disassembled the temperature control; i.e., pulled off the control knob; removed 3 screws holding unit to top of freezer; pulled two wires from their connectors to the old "control unit"; pushed them onto the connections of the new unit; reassembled the control to the top of the freezer with the three screws and pushed on the control knob.
bybob
Was this instruction helpful to you?
Thank you for voting!
Freezer and Fridge were not keeping cold enough
I didn't know what the problem was so replaced all 3 parts.
What I think actually fixed the problem is the Cold Control Thermostat that is not listed here. This part accessed by removing the dial control in the front of the Freezer. Part wasn't exactly the same but worked. I looped the sensor toward the front of the dial. Also replaced the Run Capacitor from the the back of the unit (Very Easy). Replaced the Defrost Timer from the Front of the unit (Easy). Now keeping 35-40 degrees in the Fridge and -15-0 in the Freezer. Nice. I plan to replace the Condenser Fan Motor also as it is a bit noisy.
What I think actually fixed the problem is the Cold Control Thermostat that is not listed here. This part accessed by removing the dial control in the front of the Freezer. Part wasn't exactly the same but worked. I looped the sensor toward the front of the dial. Also replaced the Run Capacitor from the the back of the unit (Very Easy). Replaced the Defrost Timer from the Front of the unit (Easy). Now keeping 35-40 degrees in the Fridge and -15-0 in the Freezer. Nice. I plan to replace the Condenser Fan Motor also as it is a bit noisy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Herndon, VA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Raymond, NH
- Parts Used:
- WP10474806, WP10551502
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Retaining Clips do not go on easily
I had a terrible time getting the retaining clips on the grille. Almost broke the plastic area they fit onto. They must use a special tool to get them on. I did however finally manage to get them on without destroying the new grille.......
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from TAKOMA PARK, MD
- Parts Used:
- W11176463
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
The water supply line to the ice maker kept popping off after I replaced the water filter because an "ice plug" had formed in the fill tube, unbeknownst to me.
1. Turn your water OFF and pull the refrigerator out from the wall so you can access the back.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Rockwall, TX
- Parts Used:
- R0131577
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Not Defrosting
Disconnected power cord, Removed lower front face plate, removed one screw that helt cover over defrost timer, removed two screws that held timer, unpluged timer and removed it. Replaced old timer with new timer. Replaced timer installed two screws and replaced cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Duncan from Metairie, LA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Monica from EDMOND, OK
- Parts Used:
- W10823511
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernie from Windsor, CA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
refrigerator not cooling properly
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Valley Grande, AL
- Parts Used:
- WP67005140
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Appliance has Freezer on bottom and Someone dropped Item on handle a broke it
2 Screws on and off
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Sierra Vista, AZ
- Parts Used:
- WP10530204
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Crisper rubber seal tore off
Pulled off old ones and warmed new seals in warm water first to make it easier to slip on. Then I just pressed them on.
Was this instruction helpful to you?
Thank you for voting!