Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Leo from Lewisport, KY
Parts Used:
WPW10151374
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Unable to set the cold-control to a sufficiently cold setting.
Linkage on the cold-control mechanism in the air diffuser assembly was broken. It was necessary to access the diffuser assembly from both the refrigerator and freezer sides of the unit.
Re-connected the linkage between the diffuser and cold-control assembly; remounted the two combined assemblies . . . refrigerator working nicely now.
36 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gerardo from el monte, CA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
compressor didnt turn on
changed the starter connected to the compressor
24 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brett from garland, TX
Parts Used:
WP2198202
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
freezer intermitently warmed to around 31 degrees
Being a jet mechanic I had to familiarize myself with refrigerators, then after 2 or 4 hours of online studying, opened the door pulled the temp knobs of, removed the panel by gently prying the top of the panel out,then up and out with it. I found tapping on the thermostat shaft or wiring connection started the compressor, verifying my belief it was the thermostat. Don't mess with wiring if you don't know exactly what you are doing and unit is plugged in, you will electrocute yourself!!! I received the thermostat, UNPLUGGED THE UNIT from the house wall outlet, took one screw out of the upper inner wall at the very top to remove cover, one screw at the back top to remove the other cover (at the control vent) for access to remove sensor, then removed 4 screws , 2 front, 2 underneath to drop the housing for defrost timer, etc., and then took 2 screws from thermostat, unplugged wiring from thermostat (3 wires, be sure to put them back on the same place in the new thermostat). Remove old thermostat, slide plastic cover off sensor and slide back onto new thermostat sensor. Be careful not to kink the line or bend it to sharp you will damage it, (use gentle curves when bending it,) and re assemble everything in reverse order. This took about me 15 or 20 minutes start to finish. Plug into wall and watch thermometer to verify success.
16 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from DELRAN, NJ
Parts Used:
WPW10614158
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Water leaking from under refrigerator.
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for leak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.

The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
15 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Cedarville, OH
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers, Socket set
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Hudson, FL
Parts Used:
W10822278
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator quit refrigerating
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Arnold, ME
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
I had frost build-up in the freezer.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Pottstown, PA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Noise coming from defrost timer
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Maxine from Birmingham, AL
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
would not cycle
removed the defrost timer and replaced with new unit now i have a refrigerator again
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Brooklyn Center, MN
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Compressor would not kick on automatically
I removed the two screws that were readily in view. I then figured out the there was a faceplate which I was able to pry off after removing the temp control knobs. The temp control unit was easily accessible and was held by two screws which I removed with the nut driver. The only difficult part was replacing the plastic tubing which covered the sending unit.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Benjamin from Daytona Beach, FL
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
martin l. from JACKSONVILLE,, IL
Parts Used:
4387478
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Brigham City, UT
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
peter from saint augustine, FL
Parts Used:
W11581579
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
part of a freezer support bracket was missing
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from Middleboro, MA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!