59678533802 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Michael from WALLA WALLA, WA
- Parts Used:
- WPW10300024
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
original ice maker would make ice and then water would over flow into ice bin and freeze
first of all,i just want to thank parts select for sending me a second ice maker at no charge.after installing the first one and it didn't work,i talked with Heather and she sent me a new one.installation went the same as before.hardest part is getting the quick connect wire harness apart and the ice fill arm .it is working great and my home is happy.thank you!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from LEWISTOWN, MT
- Parts Used:
- WPW10312696
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice maker not receiving water refill
Replaced water/ice maker inlet valve from video instructions from Just Answer. The inlet tube for the water dispenser would not cede in the valve and this created a leak problem from the water dispenser connection. Called repair tech and he could not get the line to cede correctly in the inlet valve. Am going to request a replacement part. This has been very frustrating!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from MT PLEASANT, MI
- Parts Used:
- WPW10312696
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Icemaker was letting too much water in and freezing a big block of ice instead of making cubes
Looked online for instructions. I had to remove the shelves from inside the frig, then pop off part of the right inside back wall. The way the 3 water lines attached to the inlet valve was a terrible design. There are plastic little collars that need to be pushed back to release the water lines from the old valve, then when you install the new valve, you need to push them back to reattach the water lines. Once installed, one had a leak. No matter how hard I tried I couldn't get the little plastic collar to disengage. I couldn't push the line in further and I couldn't get it back out. Ended up cutting the line off at the valve just to get it out. Then had to cut out the piece that was still stuck in the valve. Tried to install it again and it leaked even more. Ended up putting the old valve back in and throwing away the $130 new inlet valve because there are no returns on electrical parts. Total waste of time and money ! ! ! Not happy to say the least.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerome from Goldsboro, NC
- Parts Used:
- WPW10714545
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Freezer door leaking on floor.
Open and remove door by loosening two screws on both sides of the door. Lift up and away the door.place the door on flat surface, grab and lift up on seal pulling out of reach. Clean track, alone seal on food before pressing in place. Check to make sure seal is set in place. Install door job done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from WATERBURY, CT
- Parts Used:
- W10874836
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Pin for drawer lid broke off
Empty drawer and take out . remove glass shelf and front and rear shelf braces. remove 2 screws holding pantry end cap to fridge. remove rear bracket by unsnapping clips. remove temp control arm. and reattach to new end cap. reinstall rear bracket to fridge and align end cap, align screws and tighten. reinstall drawers and shelf brackets. replace glass shelf. and reattach lid to brackets. Open beer and enjoy success.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dale from MECHANICSBURG, PA
- Parts Used:
- W10619951
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer iced up
Let the ice in the freezer melt while installing P trap drain tube
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from OTSEGO, MI
- Parts Used:
- WPW10300024
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Would not make ice.
Removed the whole ice maker unplug one wire harness replaced ice tray with new one.
Very simple.
Very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from Orange, CA
- Parts Used:
- 8201515
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker in the freezer section quit making ice cubes.
First I had to figure out how to get the old unit out so I could work on it. The three screws that others wrote about were the ones that hold the motor in place. There are 3 screws holding the ice maker in the frame, along with one screw covering the electrical connection. The electrical connection was difficult to unplug because the locking tab was on the back side of the connection and with no room to work in the freezer it didn't become apparent until several frustrating minutes went by. There were no instructions provided, the picture on the ordering page showed the complete ice maker, and for $80 you get a printed circuit board with a small round item which must be the motor/timer control. The two plastic parts for moving the ice from the ice maker were included but not replaced because I didn't notice them until I had finished replacing the ice maker back in the freezer and wasn't going to start over again.
Once installed, there wasn't any noise, even of water flowing like the old one, could not tell if the unit was working or not. In the morning there was new ice in the bin indicating the repair had been successful. This is like anything else, if you have done it before it is a 5 minuter job but when you have to look at it and try to figure it out it takes a bit longer. All in all, it was simple enough, I was expecting a complete ice maker unit like was in the picture when ordered but only the motor module was actually needed.
We have another refrigerator/freezer that has an icemaker that is over 20 years old and has never been repaired, it is a Sears model though, probably made by Whirlpool or someone else.
Once installed, there wasn't any noise, even of water flowing like the old one, could not tell if the unit was working or not. In the morning there was new ice in the bin indicating the repair had been successful. This is like anything else, if you have done it before it is a 5 minuter job but when you have to look at it and try to figure it out it takes a bit longer. All in all, it was simple enough, I was expecting a complete ice maker unit like was in the picture when ordered but only the motor module was actually needed.
We have another refrigerator/freezer that has an icemaker that is over 20 years old and has never been repaired, it is a Sears model though, probably made by Whirlpool or someone else.
Was this instruction helpful to you?
Thank you for voting!
broken nipple/hungry kids
Took bottom 2 shelves out. 2 screws held assembly in to main cabin. Remove them then 2 additional screws held drawer bracket in place. Easy yet patience and finesse is needed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Nesconset, NY
- Parts Used:
- W10874836
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Plastic food door hinge broke
Removed the food bins and lower shelf. Unscrewed the end cap. Removed the drawer hinge. Re-installed hing on new end cap. Installed the new end cap. Re-installed drawers and shelf. DONE!
Great graphics on the website helped to correctly idenitfy the required part. Part arrived quickly and well packed. One of the easiest transactions ever!
Great graphics on the website helped to correctly idenitfy the required part. Part arrived quickly and well packed. One of the easiest transactions ever!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from SMITHFIELD, RI
- Parts Used:
- WP12825803
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
I had a loose fitting old condensor fan blade on my new motor.
I made a temporary repair by drilling the old blade plastic hub and put a small screw in it to hold it on to the shaft until the new blade arrived. The new blade came in within the two days I needed before Thanksgiving. I removed the old and pushed on the new. There were 8 screws on the back guard and two to hold the motor on. It was a snap.
Thank you PartSelect.com The wife is very, very happy now, we had 51 coming over for Thanksgiving. :)
Thank you PartSelect.com The wife is very, very happy now, we had 51 coming over for Thanksgiving. :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rich from WINSTED, CT
- Parts Used:
- W10619951
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Water not draining to pan. It caused an ice build up under the freezer draw
Remove the grate at the back of the refrigerator. Remove the existing drawn tube. Replace the exiting drain tube with the updated drain tube. Check to see if water was draining properly. Replace the grate. Sit back and have a beer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from LAKE CHARLES, LA
- Parts Used:
- W11447232
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
One of the light bulbs went out on my Whirlpool refrigerator.
I changed the bulb but it still didn’t work. I ordered a bulb holder and replaced it and it works properly now. It was an easy repair, remove the bulb, gently pry the bulb holder out with a screwdriver and snap the new one in.
It was useful that under the description of the part in the catalog, it showed that this part was often used to repair this issue. The service was great and the delivery was fast.
It was useful that under the description of the part in the catalog, it showed that this part was often used to repair this issue. The service was great and the delivery was fast.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Phoenix, AZ
- Parts Used:
- WPW10300024
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice jammed on exit from ice maker
Removed old ice maker. Unscrewed unit from slide. Unplugged old wire. Screwed on new unit. Replugged in wire. Slid ice maker back into refrigerator and all worked properly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from SAN DIEGO, CA
- Parts Used:
- WPW10662129, WPW10197428
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Random clicking noise
The toughest part was pulling the refrigerator from the wall....After removing the back-bottom access panel the compressor is right there with the Start-Dev and Cap..Took a few min to remove and install new parts....Very Simple and works great...no more clicking..
Was this instruction helpful to you?
Thank you for voting!