- Customer:
- QUENTIN from WELDON, CA
- Parts Used:
- 241707715
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
NOT COOLING
First download schematic from frigidaire.com and watch a few youtube videos on fixing refrigerators .At first my guess was the timer was stuck on the defrost mode .However after studying the schematic I checked to see if the power was being sent to the compressor through the starter ptc .The 110 v was there after pulling off the connector .Also the condenser fan was on confirming this . however the compressor was stone cold .the compressor has 3 inputs whose resistances across all seemed good (see youtube videos) so it was probably the ptc starter or the 15microfarad capacitor .I changed the capacitor first -not the problem .then the ptc starter .immediatey the compressor started warming and after a few minutes cold air was being blown in .Very satisfying !
Was this instruction helpful to you?
Thank you for voting!
Broken Door Rack
There is nothing easier than this. You just take out the broken bar and put in the new one.
As easy as ABC....
As easy as ABC....
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denver from BLAIRSVILLE, GA
- Parts Used:
- 5303918549
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ANGELA from MEBANE, NC
- Parts Used:
- 316538904
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from MARTINEZ, CA
- Parts Used:
- 5308000010
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Fridge made a hellacious noise and wasn't cooling well
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PHOENIX, AZ
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Replace ice maker which was splashing water
Turn off ice maker
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Otterville, MO
- Parts Used:
- 5303918202, 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
freezer frosting over,fridge warm
removed ice maker,,and screws holding back of freezer cover,unplugged wires and removed the cover and fan.wow,only wire to element had come unplugged!went ahead and replaced thermostat,and defrost timer,both were easy to do
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Silvino from N PLAINFIELD, NJ
- Parts Used:
- 241872512
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Replace the door gasket
Pulled out the old one and popped in the new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Manuel from El Mirage, AZ
- Parts Used:
- 240534701
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
inside door rack was missing
snaped right in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Cedar Park, TX
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
unit quit cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ann from West Valley City, UT
- Parts Used:
- 240534901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The retainer bar broke
Opened the box, took part to refridgerator and inserted retainer bar in place.
Was this instruction helpful to you?
Thank you for voting!
Shelf Retainer Bar
The retainer bar was so easy I installed it in less than 5 minutes.
I highly recommend Part Select service including, ordering, their knowledge and expertise of their products.
I highly recommend Part Select service including, ordering, their knowledge and expertise of their products.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gary from ARANSAS PASS, TX
- Parts Used:
- 5308000010
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Phillip from SUNDANCE, WY
- Parts Used:
- 5303918774
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
fan motor quit working
A little difficult getting out due to restricted space, I took off the fan blade, that gave extra working room. Then it went well going back together,and it all worked as advertised. Thanks. p
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from INVER GROVE, MN
- Parts Used:
- 241798231
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
8 loud pops and then dump ice .
Turn off power. Remove ice tray. Back out the two screws with nut driver and just lift ice maker off screws. Do not bend the water fill tube in the back . Now unplug the wire and remove ice maker .
To replace, match the color of wires on plug. Adjust wires in place and water fill tube and back on to the screws. Hold in place and snug screws. Turn power back on. In 4 to 5 hours your ice will start .
FED-EX UT to MN was 13 days to deliver .
To replace, match the color of wires on plug. Adjust wires in place and water fill tube and back on to the screws. Hold in place and snug screws. Turn power back on. In 4 to 5 hours your ice will start .
FED-EX UT to MN was 13 days to deliver .
Was this instruction helpful to you?
Thank you for voting!