59676054701 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Julie from San Diego, CA
- Parts Used:
- 67003796
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Insulation was disintegrating.
On the back of the refrigerator, I unscrewed and removed the lower-right panel. As I peeled the insulation off the panel, the insulation would disintegrate, so I used a vacuum-cleaner hose to remove most of the insulation. I removed the remaining adhesive with my fingers. I peeled the backing off the new insulation, and stuck it to the panel.
I had ordered two pieces of insulation, hoping to also replace the insulation behind the compressor, but removing the compressor was complicated and risky, so I returned the second piece of insulation.
I had ordered two pieces of insulation, hoping to also replace the insulation behind the compressor, but removing the compressor was complicated and risky, so I returned the second piece of insulation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Aquilino O from VALLEJO, CA
- Parts Used:
- 12002355
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer temperature goes down to -20*F before compressor stops but refrigerator side remains normal 38*F and compressor makes a grunting noise while running.
Unplug ref then remove lower(freezer) panel plus trays and thermistor’s cover/holder then remove the evaps cover. I found the evaps all frozen up. Cut and remove old thermistor, strip wires 1/2 inch then cut the new thermistor wires to length and strip 1/2 inch, use the enclosed insulated crimp type connector and put back everything in the reverse order. It works great afterwards.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rebecca from SAINT JOHN, IN
- Parts Used:
- WPW10503278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
3-year-old refrigerator wouldn't cool, digital temp. control stopped working
The digital display numbers (0= off and 7=coldest setting) controlled by the ECB would continually be replaced by straight lines, and the refrigerator would stop cooling. I tried unplugging it for a while. After plugging it in again, it worked (the digital display came on, I set it to "4" and it reached the proper temp), but the problem occurred again the following day, and then it stopped cooling entirely. I ordered the ECB, and it arrived in 3 business days. I watched the installation instruction video, took my time, double-checked the vid a few times to make sure I was doing it correctly, and replaced the ECB by myself in less than an hour. The refrigerator has been running without problems for 3 weeks now. My fridge had a different light bulb configuration than the one in the video, but everything else was the same, and it was a simple repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from SOUTH ST PAUL, MN
- Parts Used:
- WPW10503278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
refrigerator running all the time
Followed the video and installed the new Jazz board. The board cam in 1 piece which had to be separated into two pieces, but the scored area on the board made it less intimidating. At the same time I replaced the two incandescent lamps in the refrigerator area with LED lamps. Getting the housing for the control board apart was the most difficult part, installing the replacement board was a breeze.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy from BELTSVILLE, MD
- Parts Used:
- WPW10503278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer box frosting up. Refrigerator not cold.
My son (who does HVAC, but not appliance repair) did some investigating by taking front and back panels off and determined that the evaporator coil was freezing over because the defrost wire was not heating up. He and his girlfriend did some real-time internet searching for diagnostic info because NO control diagram was included with the refrigerator. He determined the problem was most likely the electronic control board. Ordered and installed a new board and the refrigerator is back to working fine. Took about 2 hours to diagnose the problem and 1/4 hour to actually install the control board. Kind of disappointing that this control board failed when the refrigerator was less that 4 years old.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Antonio from San Antonio, TX
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Duncan from Metairie, LA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Galen from WASECA, MN
- Parts Used:
- WPW10196393
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fresh Food Compartment occasionally going down to 28-30 degrees F
Failure detected as Damper Control at upper rear of compartment would continuously open/close, would never stay open or closed. Sometimes the main board would turn it off (maybe a low thermistor limit?), but it would stick open a bit, and keeping letting freezer air into fridge. Could have potentially been control board, but as it turns out after disassembly of the defective damper, the internal microswitch was stuck in the closed position so it wouldn't shut off the motor. Easy fix by gently pulling the cover off the damper control, pull out Styrofoam encasement, then a phillips to remove the damper assembly. Gently push tabs to release wire connectors. Reverse the process and you're done! If I really wanted to go on the cheap, I could have just changed the microswitch, but that looked like a shaky maneuver at best. This site saved me on this one, so happy to share my experience with this Maytag and its nasty habit of freezing my milk and eggs!! :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from HOMESTEAD, FL
- Parts Used:
- 12002355
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Top section warm, but freezer okay.
Popped off the control panel at the top behind the door. Found the thermistor and replaced it, cutting the wires and splicing the new one in. Immediately the warm section of the refrigerator was getting below freezing temperature readings, so the cooling vent was not opening. I put the old one back on and the temperature readings went back to being accurate. So this was not the problem. I believe now that the fan somehow is not blowing enough cold air up. So now I'll probably buy a fan motor and maybe a blade and try that. Otherwise the computer module I priced at $500 so I hope it isn't that. I replace the fan motor a few years ago already.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from KINGSPORT, TN
- Parts Used:
- W10613606
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Both compartments of the refrigerator were warm.
We came home from a long vacation to discover a warm refrigerator with its contents in various stages of decay.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from WESTERVILLE, OH
- Parts Used:
- W11658402
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Broken black plastic spring mechanism inside freezer rail
Remove rail and removed broken black plastic spring mechanism with new one and then replace rail.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Estel from Luling, TX
- Parts Used:
- WP67003638
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
RH door closure broke
Removed the door and replaced the broken door closure bushing. I had courteous help and responce from Parts Select people. Excelent turn around time on parts delivery.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from PENNINGTON, NJ
- Parts Used:
- WPW10128551
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Thought motor was bad freezer cold fridge hot
Ordered new fan motor
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from TAKOMA PARK, MD
- Parts Used:
- W11176463
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
The water supply line to the ice maker kept popping off after I replaced the water filter because an "ice plug" had formed in the fill tube, unbeknownst to me.
1. Turn your water OFF and pull the refrigerator out from the wall so you can access the back.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dave from Manchester Center, VT
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
reassembled the pieces.
Was this instruction helpful to you?