25374925704 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- George from Cleveland Heights, OH
- Parts Used:
- 240338101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Needed to replace shelf
I can't believe I put if off so long... so easy to do and PartSelect was very fast, efficient, and the cheapest vendor for my part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from San Diego, CA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The refrigerator wasn't cold enough.
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Lockport, NY
- Parts Used:
- 241639502
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.
I removed the broken fan from the condenser. This was very sipmle.
When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
I removed the broken fan from the condenser. This was very sipmle.
When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Arsen from Glendale, CA
- Parts Used:
- 5303918202
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
i smell very bad smell coming from refrigerator
I started look inside ,disconnected power, and open all possible compartments to see any burned part. Fortunately I fined a small part look like melted and then i went online and make my research .Then i ordered that part and change it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Melissa from Olden, TX
- Parts Used:
- 242252702
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Icemaker was producing hollow ice due to water was free flowing out the water dispenser during fill time for icemaker.
Removed old water valve w/ screwdriver, cut threads off old hose (as they just plug straight into new valve) & pushed hoses into new water valve. Solved both problems!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jack from WALLING, TN
- Parts Used:
- 241639502
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from KNOXVILLE, TN
- Parts Used:
- 241798231
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker would dump ice one time and then stop. Turning the ice maker off for a minute and back on would repeat the process.
I removed the two side mount screws with a screwdriver and disconnected the electrical plug to the ice maker to remove it. I reversed the process to install the new one.
It was the thermostat that was the problem, but I chose to replace the entire ice maker for only $25 more.
It was the thermostat that was the problem, but I chose to replace the entire ice maker for only $25 more.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- MANUEL from LOS ANGELES, CA
- Parts Used:
- 242193213
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
bottom door seal won't seal right
R&R DOOR SEAL VERY EASY TO INSTALL THANKS TO ALL
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from RAEFORD, NC
- Parts Used:
- 5304511738
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light in freezer side of upright side by side went out.
I emptied freezer side of unit, turned unit off, rolled unit away from wall, unplugged unit, turned ice maker water supply off, and took out the ice maker. I then took out old light and replaced it with new light. I then plugged in the unit, turned on the water supply, rolled the unit back in place, placed the ice maker back in the unit and turned the unit back on.
After two hours I placed the frozen items back in the freezer.
After two hours I placed the frozen items back in the freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Marco Island, FL
- Parts Used:
- 242252702
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker was over filling.
Old valve comes out with 2 screws, water lines removed and reinstalled on new valve just as they came off the old valve. Entire job took less than 10 minutes. Very easy replacement.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Reubon from Phenix City, AL
- Parts Used:
- 240434301
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
water leaking inside of refrigerator from filter area
I just removed the filter and then removed the filter housing. The housing is mounted using two screws. The only difficult part was removing the elbows from the water in and out lines. I don't believe the elbows are reusable. So I would go ahead and order new elbows when replacing this part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- will from bushnell, IL
- Parts Used:
- 5303918202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer froze up/ Fridge ran warm
Thawed out freezer, I recommend laying a couple old towels in freezer to soak up melted ice. Replaced old thermostat with new part. Removed 2 screws, removed back plate, unplugged 2 connectors and cut 2 wires. Crimped in new thermostat and repositioned to original part location. Reconnected plugs as I reinstalled back plate. Installed 2 screws and connected power. Works like new! Trouble shooting and part installation video is very helpful, great site!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leonard from WARRINGTON, PA
- Parts Used:
- 240338101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Cracked shelf
Snapped it in shelf in designated slots
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Elyse from NEW ORLEANS, LA
- Parts Used:
- 241872503
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 30 - 60 mins
It would have been nice to fix item I paid for but I never received it.
I tried contacting this page about the item I never received but I never heard back so this is my review. I DIDNT FIX IT BECAUSE I DIDNT GET ITEM.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sherry from Newberry, SC
- Parts Used:
- 5303918202
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
the freezer frosted up and the fridge was not getting cold.
I watched the instructional video and did what it said.
Was this instruction helpful to you?
Thank you for voting!