25374925703 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Leonard from Burlington, IA
- Parts Used:
- 240434301
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Housing that the water filter was cracked. I think ,setting was too cold and froze and cracked it.
It takes a 1/4 " nutdriver to take one screw out that holds the cover over the water filter. You have to come up from the botton of cover. Then take two water lines off housing , by pushing the round collar back toward the fitting,and pull fitting off housing. Then take the two screw out that hold the housing on. Make sure you have the water turned off before you start.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Erle from Boise, ID
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
First, unplug the refrigerator since you're working with live wires.
Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.
Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.
Attach the new defrost timer to the plastic housing with the 2 screws.
Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.
Plug the refrigerator back in and you're done.
Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.
Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.
Attach the new defrost timer to the plastic housing with the 2 screws.
Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.
Plug the refrigerator back in and you're done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Whittier, CA
- Parts Used:
- 242193213
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Wrench set
Original gasket damaged at bottom
At first I tried to insall the new gasket with the door still attached to the refrigerator. It was difficult to assure that the bottom of the gasket was properly installed at the bottom. As a result I removed the door from the refrigerator, finished installing the gasket and then put the door back on the refrigerator
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Belmont, OH
- Parts Used:
- 242252702
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Water Wasn't Filling Ice Tray To Make Ice.
Unpluged the item. Turned off the water source. Removed the card board cover. Dis-connected the water hoses. Unpluged the connetors. Matched up the colores and put it back together, very easy. Everythings was color coded.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Louisville, KY
- Parts Used:
- 242252702
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Ice Maker wasn't making ice
I shut off the water supply and removed the 4 screws from the cardboard back revealing the water valve. I removed the 2 screws which attach the valve to the refrigerator and removed the water valve. Once out it was a snap to unplug the electrical leads and unscrewed the water lines, Insalling the new part was a matter of reversing the above procedure. Everything is color coded which made this replacement extrememly simple.
I will definitely use you guys in the future. The ordering process was great and delivery time was ultra quick!
Thanks for an easy part replacement and simple install.
I will definitely use you guys in the future. The ordering process was great and delivery time was ultra quick!
Thanks for an easy part replacement and simple install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Miles from Longview, TX
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator freezing
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denise from Lowell, MI
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
just quit working
Bought a new
capacitor.
capacitor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from Rockwall, TX
- Parts Used:
- 216954235
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator was trying to cycle compressor on, but each time the compressor started, it would stop due to the thermo breaker would open. The fans continued to run, so I figured it was starter relay.
Moved the refrig. out, removed the four screws that held the lower access panel in place. Disconnected the power cord. Removed the retainer clip wire and pulled the relays from the compressor socket. Separated the relays and installed the secondary relay on the new starter relay. Reinstalled the starter relay assembly into the compressor socket. Plugged the power cord in and listened for the compressor to cycle on. It cycled on and continued to run. Turned the power off and reinstalled the retainer clip wire. Reinstalled the access panel and plugged the power back in and left the refrig. run overnight. Checked temperature and also started the ice maker. Everything was normal by morning.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christina from Tacoma, WA
- Parts Used:
- 240338101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
plastic hook broke
just snap the new piece in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Anderson, IN
- Parts Used:
- 242252702
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
drip from door water dispenser
The 4 lines attached to water valve have compression fittings.New valve has pex fittings.I cut each line just behind the ferrel and inserted each line into the proper fitting and reattached the 3 electrical plugs.Turned water back on.I immediately got water from thr door without dripping.For whatever reason it was not making ice for the first 3 days,I pulled the plug on the icemaker solenoid and reattached.It is working now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from ORANGE, TX
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker quit working
Followed the steps in the video on your site, really easy to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Herington, KS
- Parts Used:
- 242252702
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
It Was Fast And Easy, No To Mention Affordable.
Removed the two screws that hold the element in place. Then I pulled the element out about 3 inches and disconnected the wires. Everything matched up perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vicki from Johnson City, TX
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from San Antonio, TX
- Parts Used:
- 216954235
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Compressor would not start.
After earlier determing that the starter switch was at fault, I removed the cardboard lower back panel, shut off water to the ice maker, removed water line. The plug to the compressor containing the switch and capacitor was held on by a spring clip, removed clip pulled wires from old switch (Here needle nose pliars are handy as the spade clips on the 2 wires have their own locking clips) replaced switch and all wiring, tested unit and problem solved.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JANET from NEW FAIRFIELD, CT
- Parts Used:
- 242252702
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Ice Maker Doesn't Make Ice
I shut the water off under the sink and removed the back piece on the refrigerator, unscrewed the water valve, cut the ends off each plastic hose and reinserted into the new water valve. Then rescrewed the water line into the new water valve and turned on the water. Unfortunately, I was not able to get water out of the door and the ice maker still doesn't make ice. While this was an easy procedure, it didn't help me. I'm not sure I needed to replace the water valve.
Was this instruction helpful to you?
Thank you for voting!