- Customer:
- Henning from RHINELANDER, WI
- Parts Used:
- WPW10128551
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Refrigerator was warm,freezer was cold
Unplugged refrigerator,cleaned out freezer.Removed shelves in freezer compartment(that took some figuring to unlock sliding sheves)Our freezer is on the bottom.Removed four screws from back cover to expose fan,removed screws and attached wires.Carefully opened plastic clips after pulling fan off shaft.Replaced old motor after reattaching rubber seals.Closed clips to hold motor and placed fan back on shaft.Reattach wires and screws. Put cover back and replaced shelves.Plugged in refrigerator and wallah refrigerator part was cold again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from MABLETON, GA
- Parts Used:
- W10619951
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Easy fix for Whirlpool refrigerator
I followed the video provided by Part Select. I also let the refrigerator stay unplugged overnight with all the doors open. This p-trap kit has fixed the leaks out of the front of the refrigerator. There is no ice build-up in the freezer. Perfect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from MARYLAND HTS, MO
- Parts Used:
- WPW10662129
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
freezer (later fridge too) wouldn't stay cold~
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joan from SILVERDALE, WA
- Parts Used:
- WPW10671238
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
the rail broke from overloading the drawers
got the new part, took the old part out and snapped the new part in! Very easy. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Arthur from WYNNEWOOD, PA
- Parts Used:
- WPW10671238
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Rail snapped
Followed video
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Adam from GLOVERSVILLE, NY
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Bismarck, ND
- Parts Used:
- WPW10655367
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
drip pan was cracked
Removed rear cover, removed fan and than drip tray. install new tray and reassemblied
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Chelmsford, MA
- Parts Used:
- WPW10280613
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken basket hanger
It was easy, remove clips and install new basket hanger and then just clip on the clips.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PHOENIX, AZ
- Parts Used:
- W11613295
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The refrigerator was working for just 1 minute and breaks, I discovered that the fan was not working , I understood that there wsa something wrong with the condenser fan motor. I just order a new one.
The installation video for condenser fan motor helped a lot to know how to disconnect the old fan motor and connect the new one. So easy just know how to remove and put back the fan gently, observe carefully where is the center and the connector position; 15 min after everything was done and the unit works well to date.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from McKinney, TX
- Parts Used:
- W10619951
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Water pooling on the floor.
This problem is caused by a "Duckbill" rubber grommet attached to the bottom drain tube of the freezer. This duckbill opens up during the defrost cycle and allows water to drain down the "water slide" to the evaporator pan. It doesn't take much to gum the Duckbill. Once gummed up the defrost water is trapped. The Defrost Cycle eventually makes the water flow out of the coil area to the bottom of the freezer then eventually to the floor. The repair involves unplugging the unit, removing the bottom back cover with a 1/4 nut driver, pop the power clip out to give you room, reach in and pull the duckbill grommet and the water slide, then installing this replacement drain kit. This is a p trap replacement that actually fixes the root cause of this problem. A tricky part is removing the water slide, you can see the white snap that holds the slide in place. Using a small flat blade from the top releases the snap and the unit is pulled upward rather easily. This replacement drain clip snaps in the same place. If I had to do this again it wouldn't take more than two minutes to replace. Oh, one major thing, you need to manually defrost the unit. I pulled the front door off, it is held with 4 screws ... don't remove them just loosen them and it pops off easily. I pulled the bottom tray out an it gave me room to squirt hot water with a baster into the back freezer area. Eventually everything thawed out. If I had it to do over I would have waited on connecting the tube to the evaporator pan and placed the bottom of the tube into a small sauce pan or something to collect the drain water and easily dump it into the sink. I used a sponge and that took forever. BTW, just to reiterate, use this item and not that Duck Bill for replacement, this actually fixes the root cause of this problem!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel F from CALEDONIA, MN
- Parts Used:
- W11613295
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer and refridgerator just stopped working.
The Condenser Fan Motor was already removed due to searching for the problem. The new fan motor looked different from the original but I felt very comfortable that Part Select had sent me the new part showing original part number changing numbers over the years. Simply placed the fan blades onto the new motor lined up 2 of the holes placed screws and tightened then plugged the wire ribbon into the Condensor Fan Motor, plugged in the Refridgerator and it worked beautifully.
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Colorado Springs, CO
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Doug from Lancaster, CA
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- lawrence from TRAVERSE CITY, MI
- Parts Used:
- WPW10196393
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
Noisy, running constantly motor in damper unit.
Unsnapped and pulled off small cover exsposing two phillips head screws. I removed larger cover and styrofoam insert fully exsposing the damper unit. i unplugged same and with a 1/2 inch wood chisel was able to release the "snaps" holding the old unit in place. Simply reverse procedure to install new unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from NEWTON, NJ
- Parts Used:
- W10619951
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Fridge was leaking water because of bad drain
Switched the drain out using the video tutorial
Fixed the problem
Have had no more drain issues
Fixed the problem
Have had no more drain issues
Was this instruction helpful to you?