- Customer:
- Marcos from E STROUDSBURG, PA
- Parts Used:
- 240362601
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
The Refrigerator was not cooling properly. At 40-45 degrees milk spoiled
My upper and bottom air diffuser was missing.
Purchased both air diffuser and placed it.
Purchased both air diffuser and placed it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John A from BRUNSWICK, GA
- Parts Used:
- 242252702
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
No water to ice maker
Original unit had screw on lugs. After removing old unit, I unscrewed the lugs, cut the lines to remove the nuts and inserted them into the new unit. Everything was color coded so connection was simple. Reinstalled unit, cycled the ice maker several times only to discover the fill tube at in the freezer had frozen ice blocking the tray from getting water. Used a hair dryer to thaw out the tube, water flowed instantly. Very easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from HOUSTON, TX
- Parts Used:
- 240356501
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Rail had split and would not support drawer.
Removed drawer. Removed shelve. Flipped shelve over. Removed one screw. Undid tab on each end. Removed bad rail. Replaced with new rail and reversed order. Easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from SABINSVILLE, PA
- Parts Used:
- 5303918202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
freezer cold and frosting up but refrigerator warm
inside the freezer compartment, remove four hex head screws from rear panel,lift panel forward and unplug wire assembly from panel. find old defrost thermostat attached to copper tube by clip on back of thermostat, unclip, snip two wires to thermostat, take new thermostat, strip 1/4"of wire from wires in freezer (thermostat is prestripped),insert light blue wire from thermostat and light blue wire from freezer into opposite ends of crimp connector and crimp securely. repeat with dark blue wires. set panel back in freezer,connect plug to back of panel, refasten screws and you are go to go! save yourself the price of a new refrigerator or $300 repair by repairman!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from BOZEMAN, MT
- Parts Used:
- 240505801
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light Switch too loose so no longer triggered by the door.
Googled it on Youtube - unplugged the fridge, used a paint scraper to loosen the old light switch, unplugged it from the electrical source, connected the new switch, replaced the whole unit into the proper location and pushed it firmly into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from ORMOND BEACH, FL
- Parts Used:
- 240505801
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light Switch not working properly
After unplugging the fridge, I took a small flat headed screwdriver and carefully pried off the light switch from the inside, right side of the refrigerator. I disconnected the 2 wires from the switch and replaced it with the new switch and pushed it back into the frame of the fridge. Done !! Very very easy !! Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Margery from WOODBURY, NJ
- Parts Used:
- 242193214
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
rubber seal was wore out
just pull the old off and put the new one on the magnetic strip inside the rubber was the key it just grabbed the area real easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harriet from LOCKWOOD, NY
- Parts Used:
- 240365401
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
It was broken in the front part that hooked in the hole
Took the drawer and shelf out then took the screw out and took the old one out and then put the new one on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judy from ROYSE CITY, TX
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Freezer wasn't cooling - compressor not engaging
Ordered the Capacitor and the Thermostat Control. Parts were received in a matter of a few days, easy to install, but did not fix the problem. Had to call a repairman to fix the problem (compressor relay - this part not available to order for this model number with Parts Select). Will continue to use Parts Select in the future for other parts, but not happy that the actual part I needed was not available - had to use other methods.
Was this instruction helpful to you?
Thank you for voting!
Refigerator not cooling
I followed your video instructions, is very important to have this information.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sherry from Newberry, SC
- Parts Used:
- 5303918202
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
the freezer frosted up and the fridge was not getting cold.
I watched the instructional video and did what it said.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Wapakoneta, OH
- Parts Used:
- 240434301
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Filter housing froze and cracked
Be sure to shut off the water supply to the refrigerator before starting this project in case some one tries to get water thru the water dispenser before you get this replaced or you will have a fridge with a lot of water in it!
Removed the screw that held the cover over the filter housing. removed the two screws holding the housing to the wall. The quick connect elbows were next removed. replaced the cracked housing with the new housing connecting the elbows first then remounted the housing to the wall. Then replaced the cover and was done in less than five minutes. Turned on water and checked for leaks
Removed the screw that held the cover over the filter housing. removed the two screws holding the housing to the wall. The quick connect elbows were next removed. replaced the cracked housing with the new housing connecting the elbows first then remounted the housing to the wall. Then replaced the cover and was done in less than five minutes. Turned on water and checked for leaks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from RAEFORD, NC
- Parts Used:
- 5304511738
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light in freezer side of upright side by side went out.
I emptied freezer side of unit, turned unit off, rolled unit away from wall, unplugged unit, turned ice maker water supply off, and took out the ice maker. I then took out old light and replaced it with new light. I then plugged in the unit, turned on the water supply, rolled the unit back in place, placed the ice maker back in the unit and turned the unit back on.
After two hours I placed the frozen items back in the freezer.
After two hours I placed the frozen items back in the freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leonard from WARRINGTON, PA
- Parts Used:
- 240338101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Cracked shelf
Snapped it in shelf in designated slots
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- will from bushnell, IL
- Parts Used:
- 5303918202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer froze up/ Fridge ran warm
Thawed out freezer, I recommend laying a couple old towels in freezer to soak up melted ice. Replaced old thermostat with new part. Removed 2 screws, removed back plate, unplugged 2 connectors and cut 2 wires. Crimped in new thermostat and repositioned to original part location. Reconnected plugs as I reinstalled back plate. Installed 2 screws and connected power. Works like new! Trouble shooting and part installation video is very helpful, great site!
Was this instruction helpful to you?
Thank you for voting!