Customer:
Suzanne from STERLING HTS, MI
Parts Used:
4387478
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator light would not turn on.
I first replaced the switch and had no results, I then ordered the Light Socket Kit, and because I had the experience of removing the panel to replace the switch, it took a few minutes to remove the two screws behind the panel, removing the temperature control knobs and then releasing the face plate which is secured by tabs at the bottom. The kit came with extra connectors in case they were needed, but they were not in my case and so I pulled off the wires, pushed the old socket out and the new one in. Attaching the wires to the correct pins, I screwed in the light bulb to be sure that the fix was correct and determining that, I replaced the screws that held the panel in place. Voila, I'm a happy camper who found some outdated jars in the back corners of the newly lighted shelves.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack from Austin, TX
Parts Used:
WP2309517
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Snack pan drawer was out when refrigerator door was closed. The snack pan drawer was cracked and needed to be replaced.
Replacing the drawer was extremely easy. The refrigerator door need to be completely opened. Drawer slides out very easily and new drawer slides in where old drawer came out. Three minute job, tops.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rebecca from ELYRIA, OH
Parts Used:
WPW10276341
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Shelf broke when I was trying to remove it.
I ordered another shelf w glass. Put back in refrigerator and it fit perfectly.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Bloomington, IL
Parts Used:
WPW10276341
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
One of the shelves broke and needed to be replaced
It took less than one minute to open the box and place the shelf in the fridge!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jessica from WILLIAMSBURG, VA
Parts Used:
WPW10225581
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Part went bad the freezer was freezing up and refrigerator not getting cold
I pulled off the panel covering the part in the freezer cut and stripped the wires. Used crimper and connectors put the new part on put the wires band panel back on and plugged the refrigerator back in. Everything works just fine now.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from POWELL, OH
Parts Used:
W11700559
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Getting Ice Maker to sit in place prior to tightening screws.
Don not completely remove holding icemaker screws. Unit slips over screws and drops down into place and the use nutdriver to tighten in place. Rest of unit was sound and wasn’t replaced.
After icemaker is installed wait for a while and unit self activated and creates ice cubes.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roy from BEAUMONT, TX
Parts Used:
WPW10276348
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Bin right mounting rail worn, requiring a new bin.
From the Expanded view on the website, I chose the bin -I thought. The expanded view picture is too small and I got the shelf instead. -But a phone call got everything back on track.
Repair involved a knife to open the box!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from ROYSE CITY, TX
Parts Used:
WPW10276348
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Replaced cracked slide out glass shelf with new one
Simply slid out damaged shelf and slid in new one
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from GARLAND, TX
Parts Used:
WP2188656
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Grandkids try to close the refridge door ...while the drawer was open...the are kids
just slide the new compartment in
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from HOUMA, LA
Parts Used:
W11700559
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Installed a Ice Maker
Very easy to install
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
riley from CAVE CREEK, AZ
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Corona, CA
Parts Used:
WPW10329686
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Broken Freezer Door Cams
1. Put pieces of wood under door to support it.
2. Unscrew three screws holding door hinge.
3. Disconnect water line.
4. Unscrew screw holding each cam. One to door and one to hinge.
5 Replace cams.
6. Retrieve plate with threaded holes behind frame that the hinge attaches to.
7. Use thin philips screwdriver through the hinge bracket, shim, frame and screw plate to align it for the other two screws.
8. Replace all three hinge screws.
9. Connect water line fitting.
10. Remove wood for door support.
11. Check door for smooth movement and strong pressure when closed.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frederick from APEX, NC
Parts Used:
WP2176759, 4389144
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Noisy operation (from the inside)
Unplug, then on the freezer side, remove the drawers, then remove the screws holding the sheet metal cover, remove the rails (for the drawer) that interfere with removing the sheet metal cover. pull the wires off the motor. There is a big plastic piece that holds a small plastic piece that holds the motor. Remove the plastic piece that holds the motor/fan (you might be able to swap the motor by removing the little plastic piece that holds the motor, or you can remove the bigger piece and then remove the small piece that holds the motor). Pull the fan blade off (to reuse), swap the motor. NOTE - the new motor wire terminals may be on the opposite side of the motor vs. the old motor - that is not a problem - there is plenty of room for the wires. After the motor is installed put the fan blade back on, reinstall the removed plastic pieces in the back of the refrigerator. Now, I'd suggest a quick test. Make sure the new motor works and the fan blows before you button it up. Once you know it works, power it off, and put the sheet metal cover back on, reinstall the basket brackets, put the baskets back in place, close the door, and turn it back on.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!