Models > 59657013600 > Instructions

59657013600 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 59657013600
121 - 135 of 840
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Terry from WARMINSTER, PA
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Julie from San Diego, CA
Parts Used:
67003796
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Insulation was disintegrating.
On the back of the refrigerator, I unscrewed and removed the lower-right panel. As I peeled the insulation off the panel, the insulation would disintegrate, so I used a vacuum-cleaner hose to remove most of the insulation. I removed the remaining adhesive with my fingers. I peeled the backing off the new insulation, and stuck it to the panel.

I had ordered two pieces of insulation, hoping to also replace the insulation behind the compressor, but removing the compressor was complicated and risky, so I returned the second piece of insulation.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Florance, MT
Parts Used:
WPD7749401
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Auger in the ice tray not turning
Removed ice container, replaced end cap that holds Auger shaft that connects to shaft that turns the Auger. End cap plastic nubs wear where it makes contact to the turning stub. Removing a few screws on the front of ice container allows the Auger shaft to slide forward and away from the end cap. Maneuver end cap from shaft, replace using same maneuver and that is it.
Pretty easy, even for a novice like me. A $6.00 end cap verses the whole assembly at around $70.00
I'm pleased.......
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from GRAND HAVEN, MI
Parts Used:
WP67006687
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Old kickplate grille had broken retainer tabs
Open both the fridge and freezer doors prior to attaching the new grille
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Denver, NC
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Orlando from Bayonne, NJ
Parts Used:
WP2300868
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Old one leaks on one side
Simply cut the water tube on both sides of connector and push in the new one.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Johnson City, NY
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from WASHINGTON, DC
Parts Used:
W11291138
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Light switch that causes light to turn on when door is open was nroken.
Truth is, this took a couple hours of cursing, but that was due to poor information and no prior experience. I imagine the next one would take 20 minutes. The issues are these: videos tell you to use a putty knife to pry the old switch out. That is harder than it seems because each switch has a plastic spring that pops open to hold the switch on, and you can't access the spring when the switch is installed. So it is important to use the knife on the side of the switch (left or right of spring -- look at the new switch), and back and forth until the switch is worked out. Then it can get worse. The new switch has to plug in electrically before it can be installed mechanically. In my case, with the switch on the fridge wall rather than the top, the outlet for the plug was encased in foam insullation. That gives the appearance that the plug was fixed, immovable, which makes it impossible to plug it in electrically before the switch is in place, and of course once it is in place you can't then plug it in. The problem here was poor instructions. Just scrape out a lot of the foam around the plug and you find that the plug is really not fixed, but attached to reasonably long wires that allow you to plug it in with the switch a couple inches from the wall, and then insert the switch. None of the online instructions tell you this about the wires.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Valencia, PA
Parts Used:
D7824706Q
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Ice maker just stopped making ice
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Lake Mary, FL
Parts Used:
WP67004188
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
fridge to warm, icing up every three days
Wrong part, found the problem. Start with the thermostat, controls both when to start and stop the defrost cycle. Not the defrost heater or the timer.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from BELTSVILLE, MD
Parts Used:
WPW10503278
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer box frosting up. Refrigerator not cold.
My son (who does HVAC, but not appliance repair) did some investigating by taking front and back panels off and determined that the evaporator coil was freezing over because the defrost wire was not heating up. He and his girlfriend did some real-time internet searching for diagnostic info because NO control diagram was included with the refrigerator. He determined the problem was most likely the electronic control board. Ordered and installed a new board and the refrigerator is back to working fine. Took about 2 hours to diagnose the problem and 1/4 hour to actually install the control board. Kind of disappointing that this control board failed when the refrigerator was less that 4 years old.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
riley from CAVE CREEK, AZ
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lanny from LYNN HAVEN, FL
Parts Used:
WP67004757
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
Amana Side by Side - refrigerator side began to not cool, freezer side froze up
Problem led to 3 possible problem parts, defrost thermostat, defrost heater or defrost control board. Defrost heater ohmed out to 31 ohms, so seemed good. Defrost thermostat was open when warm but was open after running refrigerator to get freezer side cold enough for thermostat to close, it did not I thought. So I ordered thermostat. Once part came in, I cut up a couple inches on orange and brown wires, stripped off enough to work with. I soldered new one in and heat shrunk the wires. I turned on and it seem to work and all night. Working fine right now.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne from LEXINGTON, KY
Parts Used:
WP67006524
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set, Wrench set
Water flow from dispenser was just a trickle. After watching a couple videos on Youtube, I realized it was the water filter head, a part that just wears out after a few years.
First I checked to see if the water pump in the base of the refrigerator was working properly. To do this, I removed the water filter, placed the by-pass cap on the water filter head, and dispensed water. The dispenser worked very well so I knew it was not the pump. I had just bought a new filter so it was okay too. So I figured it was the Water Filter Head assembly. To install, I followed previous advice on Part Select website and followed a YouTube video that was excellent (enter "Refrigerator Water Filter Head and Tube Assembly-How to replace). Best advice...Styrofoam block that inserts from back of refrigerator where tubing enters...when removing, push it out from the inside of the refrigerator to avoid breaking it into pieces. Other good advice, unplug refrigerator and turn off valve to icemaker and water dispenser. Easy repair, could do it in half the time now because I was very careful when installing this item. Results: Excellent flow from dispenser!!! And better ice cubes too! Well worth the effort.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leon from TUSCOLA, TX
Parts Used:
WP12562701
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice Chute door broke off and fell to the floor
Unplugged refrigerator.
Removed water drip tray.
Removed two Phillips screws.
used putty knife to
get behind outer plate and popped it off.
Disconnected electrical connections.
Removed the 4 nut driver screws.
removed ice maker door.
Removed seal around old Ice shoot flap and cleaned.
Removed insulator pad from old ice maker flap and cleaned.
Installed seal and insulator pad on the new chute door.
clipped new chute door intact with seal and pad in place and snapped the top clips into place.

Reversed procedure to reinstall refrigerator parts.

Plugged in refrigerator and tested. Had no issues.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 59657013600
121 - 135 of 840