Models > 59669980001 > Instructions

59669980001 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 59669980001
46 - 60 of 176
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Arthur from WYNNEWOOD, PA
Parts Used:
WPW10671238
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Rail snapped
Followed video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from GLOVERSVILLE, NY
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Lancaster, CA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from HELENDALE, CA
Parts Used:
WPW10662129
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer would not freeze
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thick. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from McKinney, TX
Parts Used:
W10619951
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Water pooling on the floor.
This problem is caused by a "Duckbill" rubber grommet attached to the bottom drain tube of the freezer. This duckbill opens up during the defrost cycle and allows water to drain down the "water slide" to the evaporator pan. It doesn't take much to gum the Duckbill. Once gummed up the defrost water is trapped. The Defrost Cycle eventually makes the water flow out of the coil area to the bottom of the freezer then eventually to the floor. The repair involves unplugging the unit, removing the bottom back cover with a 1/4 nut driver, pop the power clip out to give you room, reach in and pull the duckbill grommet and the water slide, then installing this replacement drain kit. This is a p trap replacement that actually fixes the root cause of this problem. A tricky part is removing the water slide, you can see the white snap that holds the slide in place. Using a small flat blade from the top releases the snap and the unit is pulled upward rather easily. This replacement drain clip snaps in the same place. If I had to do this again it wouldn't take more than two minutes to replace. Oh, one major thing, you need to manually defrost the unit. I pulled the front door off, it is held with 4 screws ... don't remove them just loosen them and it pops off easily. I pulled the bottom tray out an it gave me room to squirt hot water with a baster into the back freezer area. Eventually everything thawed out. If I had it to do over I would have waited on connecting the tube to the evaporator pan and placed the bottom of the tube into a small sauce pan or something to collect the drain water and easily dump it into the sink. I used a sponge and that took forever. BTW, just to reiterate, use this item and not that Duck Bill for replacement, this actually fixes the root cause of this problem!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nancy from LOUDON, TN
Parts Used:
WP67006877
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
broken glass shelf
Replaced shelf, very simple
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from Bismarck, ND
Parts Used:
WPW10655367
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
drip pan was cracked
Removed rear cover, removed fan and than drip tray. install new tray and reassemblied
28 of 82 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from GLOUCESTER PT, VA
Parts Used:
W11489993
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Replaced left side guide on the freezer basket drawer.
Removed Phillips head screw on the front cover of both guides. Pull the drawer forward until it stops. Snap up the cover on each geared wheel to allow the basket to lift enough to continue removing the basket.
Swing the front of the guide rail towards the back which allows for the rear tab to come out of its hole.
Put new guide back in following reverse order.
Done!!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Wilmington, NC
Parts Used:
WPW10671238
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Broken center crisper rail
I took all items off the glass shelf. Removed the two crisper drawers. Removed the glass shelf. Installed the center rail. Replaced the two crisper drawers, the glass shelf and all items. Job done in less that 1 min. Thank you for great customer service and quick delivery.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jacqueline from LEXINGTON PK, MD
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
No cold
Like you video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from FORD CITY, PA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Freezer occasionally had a temperature alarm.Clicking noise also.
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Neil from WILMINGTON, MA
Parts Used:
WPW10671238
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Broken center crisper rail
Lift off glass shelf and insert tabs of rail on each end , replace shelf.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jacob from SHEBOYGAN, WI
Parts Used:
WP67006877
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Old glass broke , new glass fit perfect
Just set the glass shelf onto frame perfect fit
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Colorado Springs, CO
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel F from CALEDONIA, MN
Parts Used:
W11613295
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer and refridgerator just stopped working.
The Condenser Fan Motor was already removed due to searching for the problem. The new fan motor looked different from the original but I felt very comfortable that Part Select had sent me the new part showing original part number changing numbers over the years. Simply placed the fan blades onto the new motor lined up 2 of the holes placed screws and tightened then plugged the wire ribbon into the Condensor Fan Motor, plugged in the Refridgerator and it worked beautifully.

The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 59669980001
46 - 60 of 176