Marc from SEASIDE, CA
Parts Used:
WPW10503278
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
the freezer and refrigerator number would lower it self and eventually get to "-" and "-" essentially shutting it self off!!
I replaced the Control Board...
the two boards need to be installed first . than plug in the connectors
(refrigerator was unplugged of course.!) i plugged in the connectors first. and had to disconnect them. install the boards first. than plug in the electrical connectors.. strange for a day or two it still did not work properly and than one day. it started working ok 7 on the freezer and 3 on the refrigerator. I do not know why..
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherril from ROBBINSVILLE, NC
Parts Used:
WPW10503278
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
FREEZEING UP
in stalled new circuit board an thermostat an was fixed
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from MARYLAND HTS, MO
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
freezer (later fridge too) wouldn't stay cold~
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from MABLETON, GA
Parts Used:
W10619951
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Easy fix for Whirlpool refrigerator
I followed the video provided by Part Select. I also let the refrigerator stay unplugged overnight with all the doors open. This p-trap kit has fixed the leaks out of the front of the refrigerator. There is no ice build-up in the freezer. Perfect!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from MT PLEASANT, SC
Parts Used:
WPW10503278
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fridge running warm
The fridge would occasionally run warm, requiring me to turn it off and defrost the evap coils in the freezer. I found an online video that demonstrated the entire process of replacing the control board. The fridge model in the video was different than mine, so it took some time to figure out how to remove the panel. Once that was done, the rest was easy. The only tool required was a flat-head screwdriver that was used to push in the tabs holding the panel in place. The circuit board took more effort to split in two than I had realized, and I had to be careful not to bend any of the components on its surface. The whole process took less than 30 minutes, and the fridge is working properly now..
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joan from SILVERDALE, WA
Parts Used:
WPW10671238
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
the rail broke from overloading the drawers
got the new part, took the old part out and snapped the new part in! Very easy. Thank you.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from WYNNEWOOD, PA
Parts Used:
WPW10671238
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Rail snapped
Followed video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Chelmsford, MA
Parts Used:
WPW10280613
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken basket hanger
It was easy, remove clips and install new basket hanger and then just clip on the clips.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from PHOENIX, AZ
Parts Used:
W11613295
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The refrigerator was working for just 1 minute and breaks, I discovered that the fan was not working , I understood that there wsa something wrong with the condenser fan motor. I just order a new one.
The installation video for condenser fan motor helped a lot to know how to disconnect the old fan motor and connect the new one. So easy just know how to remove and put back the fan gently, observe carefully where is the center and the connector position; 15 min after everything was done and the unit works well to date.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from GLOVERSVILLE, NY
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
lawrence from TRAVERSE CITY, MI
Parts Used:
WPW10196393
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Noisy, running constantly motor in damper unit.
Unsnapped and pulled off small cover exsposing two phillips head screws. I removed larger cover and styrofoam insert fully exsposing the damper unit. i unplugged same and with a 1/2 inch wood chisel was able to release the "snaps" holding the old unit in place. Simply reverse procedure to install new unit.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Colorado Springs, CO
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Reading, AL
Parts Used:
WPW10503278
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator was not cold.
Refrigerator was not cold.

I had this problem before and it was the control vale in the back of the refrigerator. I ordered it and change that out in 5 minutes. That wasn’t the problem. I had the repairman come over and within 5 minutes he told me what the problem was. He showed me where the control board was. He then walked me through the removal process.

First remove the light cover on the Freezer & Refrigerator in front where the light button is located. Pull down on the front of the light cover. It pops out.

Second, in the front of the freezer & refrigerator temp control panel put your fingertips in front of the panel and pull down it’s hard to get the pins to release but the front pins will release, then pull down a little to allow the back hooks to release. (You can use a small common screwdriver if you can’t get it with your fingertips).

Next, once the panel is removed then disconnect the wiring harness. Then bring the panel to the counter, this is where you remove the circuit card and replace it. There are 4 hooks that hold the circuit board in place. Use a small common screwdriver to push the hooks away from the board. The new board comes as one piece. The board is perforated to allow you to snap the board. Directions come with the board and how to snap it. You will need to pay attention on how you removed the board. You will need to put the new board in the same way it came out.

Once the board is re-installed and lock into position reverse the process and install the control panel back into position.

Next is the programing of the board. Follow the directions that come with the control board and you will be back in business

This task took about 15 minutes to remove & replace and to program.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Lancaster, CA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from GOLDEN, CO
Parts Used:
WPW10503278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
About twicw per year the freezer would ice up because the control board didn't activate the defrost element
Removed the cover using a mirror to see how to release the clips on the rear side of the cover, removed the circuit board noting how everything was installed and also visually verified the part was the same. Broke the circuit at the designated score, installed and followed instructions for programming. All is well now.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!