1069532582 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Jerome from Rochester Hills, MI
- Parts Used:
- WP2149540
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Shelf stud cracked
From a prior post, I learned that you simply turn the old stud one quarter turn to the left to pull it out. The new stud is then inserted and turned one quarter turn to the right and it locks in. Very easy repair.
Was this instruction helpful to you?
Thank you for voting!
Icemaker Wouldn't Work
I removed the screws that attached the drum housing to the bin. I detached the auger & removed the broken drum assembly, turning the auger to the right, opposite what I thought it should be. I slipped the end of the auger into the new bin coupler & put it in place at the rear of the bin. Next I slipped the auger drum into place & tightened it to the left with a socket wrench. I screwed the drum housing to the bin, put the bin back into the freezer & I now have ice through the door again. Easy repair even for me, a 60+ woman.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- roberto from san Antonio, TX
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
freezer gets too cold then gets to regular tempetured
disconect the power removed the screws with the phillips screwdriver removed the front cover and then removed the rest of the screws. removed the three covers and then removed the thermostat. replaced in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sheila from Lena, MS
- Parts Used:
- 4388736
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would no longer move ice through the dispenser
As cookbook authors and publishers, my husband and I depend on our appliances. When our icemaker would no longer work, it was imperative that we repair it as quickly and ecomonically as possible. We had used PartSelect.com earlier to order a part to repair our Jenn-Air stove top and had great results. So, rather than paying a repairman four times or more the cost of the part, we ordered the part and my husband installed it. It took less than 30 minutes to remove the broken auger and install the new one. THANKS PartSelect.com -- we'll use you for all appliance parts needs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Troy from Kansas, OK
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezer wouldn't defrost/low temps in refrigerator
Found the housing for the thermostat; took housing apart pulled out thermostat and took off the hose put the hose on the new thermostat installed new thermostat and replaced housing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Lewisville, TX
- Parts Used:
- WPW10329686
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Socket set
Refrig Door Cams wore out and made noises when opening and closing.
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two year old Frig. This is a design problem, as the cams should last longer than 22 months.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Choctaw, OK
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Aliso Viejo, CA
- Parts Used:
- WP2181722
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ice from automatic Ice maker was spilling out
I pulled out the Ice maker tray. Unscrewed the front cover where the baffle had broke off. It was very easy after I found the correct part. Your site made it easy to fix my repair. Most people would have had to purchse a new refrigerator. Thanks to you I didn't have to go that way. The part came to me in about 3 days. I am very happy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Herndon, VA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from Eaton Rapids, MI
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
The frig/freezer shut off too often and would not stay cold.
The new thermostat assembly installed quite easily, just a couple of screws, but the thermostat probe however was kind of a pain in the rear. The probe is about 3 feet long and you have to remove a plastic sleeve from the old part and re-install on the new probe, it fits very tight and takes some time to do. Overall it was a very easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Martinsville, IL
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator had shut down
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Chagrin falls, OH
- Parts Used:
- 4318165
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
door would not stay closed
Removed the top plastic hinge cover, remove (2) bolts from top hinge. Lifted door up and off of lower hinge, removed both halves of door cam, replaced cam halves and re-installed door. Super easy and effective. Door now opens and closes (stays closed) properly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sandra from RESTON, VA
- Parts Used:
- WP4388152
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Refrigerator water nozzle broke
The nozzle of the water dispenser broke. I ordered the part which arrived the next day. I did not use the white line, only the black. I turned the water off, then I removed the screw under the broken nozzle and cut off it off from the line. I took a new screw and cut off the top with pliers, then twisted half of a screw in the old line and inserted the other half in the new line and pulled the line from the bottom corner of the refrigerator and connected it to the white line under the grid. Screwed the new nozzle back to the lever, replaced the grid and turned water on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from RIVERSIDE, CA
- Parts Used:
- 8009
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STEPHEN from FENTON, MO
- Parts Used:
- WPW10225581, W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer No Longer Cools
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Was this instruction helpful to you?
Thank you for voting!