Customer:
Stephen from Jupiter, FL
Parts Used:
WR23X10725
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
PERRY from VANDERBILT, MI
Parts Used:
WR60X187
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Wrench set
Noisey Motor, Bearings Out, Dying
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joy from New Ross, IN
Parts Used:
WR60X203
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Freezer was cold, but frig was warm
First unplugged frig. Took off cover to fan, then bottom & back panels in freezer. Unplugged the fan to the wires & marked them so we would know how they went back. Unscrewed the frame that holds the fan, laid the old one next to the new one so we could tell how it went. Only took a few minutes to do this, then put it back in the same way we took it out. Plugged frig. back in & it took off. Very happy with this. Runs like a new one.
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paulette B. from Santa Ana, CA
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Light in the refrigerator went out
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.

Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.

Paulette Johnson
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
HANCEL from ELMONT, NY
Parts Used:
WR9X502
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
botton half of refrigerator not cooling
easy as 1.2.3 remove and replace before even thinking. just to let you know i also do this for a living but it is one of the most difficult thing when you have to stop and fix your own
25 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leo from TWIN FALLS, ID
Parts Used:
40A15
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
15 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from BELLEVUE, WA
Parts Used:
40A15
Difficulty Level:
Very Difficult
Total Repair Time:
Less than 15 mins
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Somers Point, NJ
Parts Used:
WR23X10725
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JEFF from HAMPTON, GA
Parts Used:
WR60X187
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
brad from brenham, TX
Parts Used:
WR60X203
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
thermistat and defrost timer
i have a friend that had a big side by side refrigerator . he had repair man after repairman come and look at it. one thought it was the overload relay in the back and another just said it was compressor problems. this went on for over a month. after all of this and no one able to fix it he went and got another refrigerator . being the tinker with stuff kind of person i am i said i will come and get the old one to keep him from having to haul it off (he agreed). well i did my home work and tried a few things messing with it. tapping on the thermistat resetting the defrost timer and it dawned on me that that the fridge would run great if i wiggle a wire on the thermistat and reset the defrost timer. so i get on the internet look around for the parts. come to find out they were realy cheap. the day they get here i break out with a screw driver and a nut driver and take the cover off. i take the old parts out and put the new ones in in about 15 minutes. i wiped the inside of the frige clean and pluged it back in. well in no time flat this thing was cooling like a northern blowing through in january. then it dawned on me that i have a 27 cubic ft frige that i didnt pay any thing for (well the 65 bucks i spent on the parts) and it runs great. what a deal.

after getting the big side by side fixed up and running like a champ i realized i have a refrigerator in the garage that my parents gave me a couple of years ago that only ran for a couple of months. well i get brave and decide to try my luck with the second one. due to it sitting up for so long and the humidity i had to do a little more work to it. i replaced a few wires, changed out a couple of connections, put a thermistat , a defrost timer and a evapmotor in it this thing also ran like a champ. i cleaned it up real good ran some steel wool over the outside and sprayed a couple of coats of enamel on it and it looks brand new.

so to end this story i spent about 140 bucks and i have two refrigerators a big side by side ice and water despensing refrigerator in the house and a 17 cubic ft refrigerator in the garage (the wife was happy simply because i had a place to put beer and bait).

if i would have went and purchased both of these refrigerators i would have spent about $1400 for the side by side and about $450 for the other one. man what a bargin, so from now on even if it seems a little dificult i dont get rid of any thing until i give it a good look over and see if i can fix it. i saved a total of $1700 (minus tax).
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
P. Michael from Tustin, CA
Parts Used:
WR9X502
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice in freezer running down sides
This is a built-in unit. Remove the external bezel at the top of the unit. Reach through the unit and unplug the frig. On the compressor unit, you'll see a vertical metal panel. Remove the metal panel and the timer is right behind it. Remove one wire at a time and switch it to the new timer. Remove timer and replace with new one.

Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Divide, CO
Parts Used:
WR60X187
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allan from Frostburg, MD
Parts Used:
WR13X596
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Bottom hinge broke - Door fell off when opening
Remove two screws that hold top hinge of freezer door. Remove freezer door, use socket wrench to unscrew pin in top of refrigerator door, and remove that door. Remove two screws that hold bottom hinge and replace hinge with new one. Then replace refrigerator door and install top pin into top of door. Then set freezer door on pin and reinstall top hinge with two screws.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ben from Warrior, AL
Parts Used:
WR9X502
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Refridgerator wouldn't cycle into defrost mode without doing it manually.
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
donald from opelousas, LA
Parts Used:
WR60X187
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
noise from condenser fan
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!