59667275790 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Winston A from Brooklyn, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from DAVISBURG, MI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker stopped making ice
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Aliki from Miami, FL
- Parts Used:
- WP628356
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- frank from NORTHRIDGE, CA
- Parts Used:
- WPD7813010
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker not producing ice
The parts were very easy to replace, however I am still without ice and cannot figure out why. I have ohm tested the contol unit and everything works fine, I am able to jump it and turn on the motor and water fill valve. Any suggestions?...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from bondurant, WY
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
refrigerator was getting warmer.
first thing i thought was the condenser was plugged so pulled out and cleaned with shop vacum backwards so it became a blower not a vacum cleaned it good and put together. wife noticed cracking noise inside freezer. took all freezer food and shelfs out. took 1/4 inch hex nut screws out and found complete condenser solid ice. did some research on internet and found parts select stories. i buy passed thermostate and hooked heating coils direct which then thawed condenser. checked timer by turning of and it worked fine until i got part and installed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Summerville, SC
- Parts Used:
- W10190935
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The icemaker quit making ice.
With instructions from PartSelect.com this was an easy fix. I tested the motor's electric as suggested and was satisfied that the Motor Module (WPL W10190935) would correct the problem. UNPLUG THE REFRIGERATOR! I popped the outside plastic cover off to expose the unit. (1) remove the wire unit that runs the length of the cube maker (2) remove the 3 screws that secure the motor unit and carefully remove it (3) carefully line up the new unit, slide in place and replace the 3 screws (4) install the wire that was removed in step(1). Connect electric to the refrigerator and wait about 2 hours for your first ice cubes. PartSelect.com is the ONLY supplier that you will ever need! Great instructions and trouble shooting suggestions. Shipping is incredibly fasssst! Customer contact is awesome. Don't hesitate to buy from them! Saved me about $200.! Good luck....Tom in SC
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jane from Albuquerque, NM
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Panama City Beach, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from colorado springs, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tonya from Grand Prairie, TX
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Holden, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Atlantic Beach, FL
- Parts Used:
- R0131577, WP10442411
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Circuit Breaker tripped/shut down frig. every 8 hrs when time switched on
Removed timer kit (this was the second time for this part)/ replaced - this is a fairly simple job and take 5 minutes. The defrost thermostat take about 10 minutes to get to and take out the old one, replacement is a 2 minute job, unplug and replace, the longest part of this job is getting the back of the freezer off and then replaced, but it is fairly simple to do. Total time to diagnose about 15 minutes, replacement parts arrived in 2 business days, replacement time 15 - 18 minutes total. Recommend getting the thermostat and timer together. The first time this happened, only order the timer but I think the problem was the thermostat all along and the time seemed to be operating but when it came on every eight hours it tripped the circuit breaker Not sure which was really the problem, but all working fine now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Fairfield, CT
- Parts Used:
- 10485501
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The slide rail was cracked in half.
I removed the shelf (that contained the slide rails) from the fridge. I unscrewed 3 screws which connected the broken slide rail to the shelf. I connected the new slide rail to the shelf with the same 3 screws. I then put the shelf back in place in the fridge. A clean job.
Was this instruction helpful to you?
Thank you for voting!
leaky ice maker - non-stick coating had failed
replaced the entire ice make - 3 screws and a squeeze -off connector and it's out. Reverse to re-install... except that the fill tube had iced up. To thaw the fill tube: unload freezer section (leave food in fridge, but keep door closed), remove ice maker. Boil water, dip drill bit (dull end) into hot water, swirl around, insert (dull end) into to fill tube. Depending on how hot you got it, maybe a tablespoon of ice will melt. Repeat many times - fill tube is about 14" long! Do not use anything sharp - you will nick the tube and ice will form causing you to repeat this procedure. Do not try to break the ice - let the heat work. It took me about 30 minutes to thaw the whole thing - it made a nive gasping noise when the final plug opened up. Re-install ice maker.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Westfield, MA
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Abnormally warm temperatures in freezer/fresh food section
After unplugging the appliance I needed to thaw a large ice buildup off the evaporator cover panel before I could even remove the panel. The freezer being on the lower part of the appliance has the evaporator mounted vertically and it was 100% encapsulated in rock hard ice. It took over an hour to thaw the ice and collect all the water with a shop vacuum, since the condensate pan began to overflow.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
Was this instruction helpful to you?
Thank you for voting!