Models > 1067659622 > Instructions

1067659622 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 1067659622
91 - 105 of 265
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Mark from Farmington Hills, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Kingsport, TN
Parts Used:
981170
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Our daughter bought a condo, the refrigerator's handle was broken.
We found the part number on the broken portion of the old part, googled Kenmore refrigerator parts, found your site, and plugged the part number in. The picture looked right, so we ordered the part, which arrived in about two days. We removed the old broken pieces from the fridge, cleaned up the glue the previous owners had tried to fix with, assembled the handle, screwed on the new part and it was as good as new. The old freezer handle was a little bit bent, so it didn't fit snugly. We were able to shim up the back of it so everything looks great. You're bookmarked for our next appliance repair! This repair was done by a 23-year-old new condo owner--her first appliance project!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Granada Hills, CA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
craig from maple grove, MN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Chesterfield, MO
Parts Used:
WP2196157
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The plastic water fill tube got cracked when we moved. I called a parts company and they told me they couldn't just sell me the tube I would have to buy a whole kit for about $50 dollars. I decided to glue the tube. It worked for a while then it started leaking. So I thought I would have to buy
I hand screwed the fill tube into the water tube and stuck it into the freezer hole. I screwed the fill tube to the back of the refrigerator.

Thanks so much! You saved me a bundle!!
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gail from Golden, CO
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broke light switch while cleaning
use kitchen knife to pry out. replaced switch assemble and pressed back into place. Could not have done this with out help from previous customers. Thanks
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Greensboro, NC
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.

Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from SAN CARLOS, CA
Parts Used:
482731
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
replacing evaporator fan
My fridge did not have icemaker add on. The evap fan is in the freezer behind the back panel. Empty the freezer section (into a cooler) and turn the fridge off. Remove all the shelves in freezer section. Remove the shelf support tabs by lifting them up. use phillips head screwdiver to remove back panel in freezer section. Use nut driver to remove fan shroud. Remove old fan and save the mounting arms. Install mounting arms on new fan and install fan. Install shroud, back panel, shelf mounts and shelves. Thats it!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from West Linn, OR
Parts Used:
4318046
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench set
Water dispenser drip when not being used.
Unplug, turn off water supply, carefully remove lower back cardboard cover, unscrew old valve mount, lay towel down, disconnect the three water lines, modify provided “L” bracket by drilling a hole outboard of one of the slots to match/fit the wider original mount holes on the refrigerator’s bottom pan, screw top/short end of bracket to valve, cut back the two clear lines about 1/2” for a “fresh” end, connect all three lines, position valve and secure with original screws (access is tight, used small 1/4” wrench), turn on water/check for leaks, install back lower cardboard, plug in and verify function.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ruff from SELMA, NC
Parts Used:
4318046
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Water not entering icemaker
Initial problem was water not entering the icemaker. Replacing the valve assembly did not solve the problem. Further investigation revealed the inflow tube to he icemaker had frozen water in it. Cleaned the ice our and water flowed a bit but not enough to fill the tray. Still investigating the problem.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Plantation, FL
Parts Used:
4318046
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Socket set, Wrench (Adjustable)
Replacement Part Looked Very Different from Original
The wire plugs on the replacement part were in different orientations and the tubing connections were push-in versus the original threaded compression type. The repair kit did come with numerous additional tubes and brackets, but there were no instructions for their use. The slots on what looked like a mounting bracket adapter were not on the same centers as my original mount so I could only use one of the mounting holes - which should be OK since it is not under a lot of load after installation. I cut 3/4" off each of the outlet hoses to get a fresh, round hose end and installed the appropriate metal hose supports in the hose ends before shoving them into the push-in fittings. The size differences in the small, sheet metal internal hose supports are subtle, so be sure to double check them before installation. Be sure to press the hoses in fully or you will have a mess on your hands when you turn on the water (ask me how I know). I had to do some small re-routing of the wires to connect to the new wire connector locations (the wires were long enough). The inlet water connection was the same as original (screw on compression). I had no issues with that. After installation I actuated door water several times to make sure the press-in fittings would not work loose. I also monitored ice machine to make sure no leaks after several actuations. The differences in the original and replacement part were a little intimidating at first, but it can be made to work. 4 weeks so far and no issues, Very happy that a replacement part was available for my 21 year old fridge.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Lowell, MI
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MATTHEW from STOCKTON, CA
Parts Used:
4387478
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The Light Socket Burned Out.
I pulled the socket out and unplugged the wires. I replaced the light socket by plugging in the wires and snapping the light socket into place. A very simple fix.
5 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carolee from Spokane Valley, WA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch broke
Pried out old part with screwdriver. Unplugged. When new part came, just plugged it in and pushed the part into place.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from MERRIMACK, NH
Parts Used:
WP2196157
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Connection leaked as tube entered freezer
Followed video and had one problen, the metal pipe would not release as shown,so I used a hacksaw between the plastic and metal pipe, removing the metal pipe from inside as the video shows. Good instructions.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!