25338652991 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from Cedar City, UT
- Parts Used:
- 5303918277
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Old icemaker would not cycle to make ice.
I had already removed the ice maker by loosening the two screws with a 1/4" nut driver, in order to compare the design and style to the intended replacement for size and critical measurements. The replacement was almost identical. The wiring harness was 2-3" longer than the original, but after snaping the wire plugs together I simply curved the wire up and to the left to be out of the way. The hanging brackets are slotted and it was easiest to slip the back hanger over the head of the screw and let it slip down, then the front hanger was already to line up even though you can't see the screw with the ice maker in the way. I had to transfer an L-shaped metal bracket to the bottom side, matching the old assembly, and adjusting it to hold the bottom side away from the freezer compartment a little so it would hang level and secure. You have to snug the two screws with a screw driver or 1/4" nut driver by feel, since you can't see them with the icemaker in place. It took about 10 minutes to take out the old and another 10 to put in the new. We now have a full bin of ice, and the old plastic trays have been retired. I should have done this a year ago.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Erle from Boise, ID
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
First, unplug the refrigerator since you're working with live wires.
Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.
Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.
Attach the new defrost timer to the plastic housing with the 2 screws.
Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.
Plug the refrigerator back in and you're done.
Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.
Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.
Attach the new defrost timer to the plastic housing with the 2 screws.
Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.
Plug the refrigerator back in and you're done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Todd from Thornton, CO
- Parts Used:
- 5303917954, 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Fridge warming but freezer still frozen
I ordered a defrost timer and defrost thermostat from partselect.com. Parts arrived in 2 days (earlier than expected). Unplugged appliance, removed bottom cover, unscrewed 2 screws holding timer in place, unplugged timer and replaced with new part. Fastened back into place. Next removed back cover of freezer (5 screws using nut driver). Disconnected old thermostat and removed. Wires already had connectors installed. cut off the connectors with some wire left on and reconnected them to the new thermostat with the included blue wire crimps. Tried to use the shrink tube to insulate but couldn't get it snug enough. Just used electrical tape instead. Reinstalled thermostat. Reassembled cover. Plugged in and fridge and freezer are working fine again. Thanks partselect.com.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Mount Royal, NJ
- Parts Used:
- 5303918277
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Water in the ice bin freezing all the existing ice into clumps
You have to blindly unscrew the two screws along the side of the ice maker. Once that is done simply remove the ice maker to the side to gain access to the electrical plug. Undo the plug and remove the ice maker completely. Install the adapter on the new ice maker and install it in much the same way you removed the old. I started the (2) 1/4" screws before installing the new ice maker to make it easier to hang. Pay careful attention to the wire harness and dress it out of the way. Finally tighten the two screws and make sure the bail wire is down to begin ice making once again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Miles from Longview, TX
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator freezing
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from New York,, NY
- Parts Used:
- 5308007123, 218730603, 215473602, 215366002, 215267701
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
My electric bill was super high. $450 for 1 month for a 1bdrm apt in NY city
I took a look at the web site where I purchased the parts, then I took a look at the paper enclosed with the order. Thankfully, I have a battery operated screw driver since there are so many screws. There are plenty of screws in my refrigerator and freezer doors. I thought that since my old door gaskets were all chewed up looking, if I changed them, the 10 year old air conditioners and the old fashioned light bulbs to instant on energy saver light bulbs, the electric bill would become more manageable.
The refrigerator and freezer door gaskets were the first step. They were easy to swap out. You just need to empty the door of all food items, then pull back the old gasket to see the screws. There are alot of them. You should leave 2 loosened screws on each side of the refrigerator door to hold the panel in place while you work and remove the rest. Then you can remove the old gasket and slide the new one into place. Make sure as you tighten the screws and replace the ones you removed, the new gasket fits into the door panel groove securely and is in place as you tighen the screws. Make sure it is in place all the way around the door as you work. You repeat the procedure for the freezer using only one loosened screw on each side to keep the interior panel in place while you work. It takes some time due to the number of screws, but the work is pretty easy. I never even broke a nail.
The end caps for the shelf bars just snap into place just as the old ones can be snapped out with a bit of pressure. They do not have to be wrestled and you need to work carefully so that you do not break them. (I ordered an extra just in case, but I didn't need it. I will have it in case I need it in the future)
My electric bill dropped from $450 to $110 a month with all the improvements I made. Thank you Part Select for taking the fear of screwing it up, out of the repair process and making it manageable. I can afford my electric bill now. Thanks for your help.
The refrigerator and freezer door gaskets were the first step. They were easy to swap out. You just need to empty the door of all food items, then pull back the old gasket to see the screws. There are alot of them. You should leave 2 loosened screws on each side of the refrigerator door to hold the panel in place while you work and remove the rest. Then you can remove the old gasket and slide the new one into place. Make sure as you tighten the screws and replace the ones you removed, the new gasket fits into the door panel groove securely and is in place as you tighen the screws. Make sure it is in place all the way around the door as you work. You repeat the procedure for the freezer using only one loosened screw on each side to keep the interior panel in place while you work. It takes some time due to the number of screws, but the work is pretty easy. I never even broke a nail.
The end caps for the shelf bars just snap into place just as the old ones can be snapped out with a bit of pressure. They do not have to be wrestled and you need to work carefully so that you do not break them. (I ordered an extra just in case, but I didn't need it. I will have it in case I need it in the future)
My electric bill dropped from $450 to $110 a month with all the improvements I made. Thank you Part Select for taking the fear of screwing it up, out of the repair process and making it manageable. I can afford my electric bill now. Thanks for your help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denise from Lowell, MI
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
just quit working
Bought a new
capacitor.
capacitor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JAMES from HENDERSON, NV
- Parts Used:
- 5303918277
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ice Would Not Work - But Water Disp Did
Shut off water/power - pulled tray -loosened two screws holding ice maker - lifted it up and off - unhooked power connection installed new maker in reverse of above - power supply line was much to long but just pushed it under the ice tray ( away from the maker ) prior to ordering looked at comments from others regarding installation
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dee from Central Point, OR
- Parts Used:
- 5303918277
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Our Ice Maker drove us nuts with noise from cubes getting stuck.
I purchased the replacement part (no instructions sheet) from another company, not this one, that cost 2X's a much as this company. So I sent it back and ordered from this company. Got it faster then the post office sends us the stamps we order by internet and this ice maker had instructions.
Our's is a side by side refrig, so working space is limited but do-able. The old ice maker has made a clicking noise for years while trying to push the cubes out of the tray. They would get stuck and refreeze, sticking half way out of the tray.
I loosened the 2 screws with a socket driver (which are difficult to see), raised the unit up and off the screws. Unplugged the power & out it came. Removed the bracket on the side as instructed to attach to the new ice maker and in the trash the ol' ice maker went. Set the new ice maker on the screws, plugged in the power, tightened the screws and walla. A quiet ice maker. In fact, it would startle us the first day as we didn't hear the clicking noise indicating it was stuck. All of a sudden the cubes just dropped into the container. Alright! Don't know why I didn't do this years ago.
Our's is a side by side refrig, so working space is limited but do-able. The old ice maker has made a clicking noise for years while trying to push the cubes out of the tray. They would get stuck and refreeze, sticking half way out of the tray.
I loosened the 2 screws with a socket driver (which are difficult to see), raised the unit up and off the screws. Unplugged the power & out it came. Removed the bracket on the side as instructed to attach to the new ice maker and in the trash the ol' ice maker went. Set the new ice maker on the screws, plugged in the power, tightened the screws and walla. A quiet ice maker. In fact, it would startle us the first day as we didn't hear the clicking noise indicating it was stuck. All of a sudden the cubes just dropped into the container. Alright! Don't know why I didn't do this years ago.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Beavercreek, OH
- Parts Used:
- 5303918277
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice make just stopped
I want to first say that before I ordered this part from "Part Select" I first went and talked with a local appliance repair shop. They quoted me a $120 charge to come out and check the problem. Then $30 and hour service fee, plus parts. He provided me a quote of about $250 for the job.
I found this part easily on the web site $77. It was very easy to instal. The only problem I had was the fact that in the side by side it was very difficult for me to get two hands inside the freezer to install it. (I have wide shoulders). Two screws loosened, no need to remove them. Just life the entire unit straight up. Unplug wire harness. Then just reverse order. Could not be easier. If you can change a light bulb you can do this.
I found this part easily on the web site $77. It was very easy to instal. The only problem I had was the fact that in the side by side it was very difficult for me to get two hands inside the freezer to install it. (I have wide shoulders). Two screws loosened, no need to remove them. Just life the entire unit straight up. Unplug wire harness. Then just reverse order. Could not be easier. If you can change a light bulb you can do this.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Alexandria, VA
- Parts Used:
- 5303918277
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice maker burned out
Removing the old unit was easy enough, just loosened two screws that attach unit to side of freezer and disconnected the wiring harness. But the new unit never goes in quite as easily because it's always just a little different from the original. In this case, the wiring ended up being about six inches longer and the excess had to be stuffed behind a shield at the rear of the unit. Theoretically, the wire could have been pushed back through the opening, but it got jammed and wouldn't go. I had to remove side rails and pry the shield forward in order to get the wiring back out of the way. The unit is a narrow side by side, so there wasn't a lot of room to move around. But it wasn't difficult, just tedious. I had to make sure the wiring did not come into contact with the heating element at the bottom of the icemaker. Once installed it worked great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Branislav from Denver, CO
- Parts Used:
- 5304404821, 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator won't cycle up
There are 3 parts that actually control cooling cycle: Temperature Thermostat, Defrost Timer and sensor/relay on the back side of the appliance. If fridge cycles up after you turn small knob on defrost time (you'll hear click, problem lies between first two components.
Replacing them is really easy. Make sure you handle thermostat wire carefully. Check for connectors holding firm.
Use schematic diagrams you may find at this site.
Good luck.
Replacing them is really easy. Make sure you handle thermostat wire carefully. Check for connectors holding firm.
Use schematic diagrams you may find at this site.
Good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from ORANGE, TX
- Parts Used:
- 241798231
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker quit working
Followed the steps in the video on your site, really easy to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vicki from Johnson City, TX
- Parts Used:
- 5304464438
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marvin from Underwood, ND
- Parts Used:
- 5304404821
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Thermostat Control contacts burnt up
The Roper part was no longer available and a substitute was not recommended. But because of the excellant descriptions and photos on Part Select I was able to find a Fridgedaire part that looked exactly like the one I needed to replace. I it fit perfectly... I am impressed and have bookmarked your site for later purchases.
The thermostat is located at the top of the refridgerator compartmennt under the freezer. Remove light bulb to access the screw at the back of the thermostat/defrost timer housing. Remove screw and slide the assembly to the back to release the 2 tabs holding the front. Remove the temperature control knob on the thermostat, remove the 3 wires connected to the thermostat noting where which wire goes for re-assembly. Using a philips #2 screwdriver, remove the 2 screws under the temperature control knob and remove the thermostat. Do not lose the screws, the new thermostat does not have mounting hardware. Piece of cake, Ice cream cake if you get the freezer working again.
The thermostat is located at the top of the refridgerator compartmennt under the freezer. Remove light bulb to access the screw at the back of the thermostat/defrost timer housing. Remove screw and slide the assembly to the back to release the 2 tabs holding the front. Remove the temperature control knob on the thermostat, remove the 3 wires connected to the thermostat noting where which wire goes for re-assembly. Using a philips #2 screwdriver, remove the 2 screws under the temperature control knob and remove the thermostat. Do not lose the screws, the new thermostat does not have mounting hardware. Piece of cake, Ice cream cake if you get the freezer working again.
Was this instruction helpful to you?
Thank you for voting!