Models > 2539305311 > Instructions

2539305311 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 2539305311
76 - 90 of 90
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Donald from Waynesburg, PA
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fan Motor Malfunction
Followed the instruction video. Removed the old one. Attached the fan blade, ground wire and connected power plug. Reinstalled with 2 screws. Works great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne T from Galway, NY
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Freezer was not defrosting thus refrigerator was not cooling
1. Unplug the refrigerator.2. Remove the storage rack and back panel in the freezer. 3. Locate the thermostat. 4. Defrost the freezer coils , i used a hair dryer. 5. Remove the thermostat from the cooling coil and then clip the connecting wires close to the unit. 6. Strip the ends of these wires and connect these wires to the wires of the replacement unit using the supplied wire connectors. 6. Heat seal with a lighter the connections using the water shield sleeves provided and further wrap connections with electrical tape. 7. Reconnect the thermostat to the cooling coil at the location it was removed from. 8. Replace the freezer back panel removed earlierand the storage rack if you have one. 9. Plug the freezer back in. My refrigerator has been working ever since the repair. There are several YouTube videos available that walk you through the diagnoses and repair process. They are very good.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ingrid from Fitzgerald, GA
Parts Used:
5303324302, 3206150
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
shelf end caps both broke and the rack came off
inserted shelf caps into rack strip then into openings and hit them with my fist (gently) till they 'seated' and locked
Was this instruction helpful to you?
Thank you for voting!
Customer:
Guillermo from Miami, FL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
gustavo from gilroy, CA
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Fridge was warm and no cold air was coming in
The repair was straightfoward. The evaporator motor I received from partselect was a different model with different wiring configurations. I cut the wires from the new motor per the instructions I received with the new motor and I did the same with the wires that connect to the fridge. Once I matched the wires and secured them with electrical caps I began to put the evaporator motor to the base and started screwing the screws the way I took them off. Once I connected the wire harness to the back of the freezer and turned it on I noticed a big difference in air flow. I was surprised at how easy it was to fix my refrigirator problem. It's been a few weeks now and the fridge is cold and working like it should. Don't be afraid of this task. it's very easy and will save you a ton of money. Thanks partselect.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Goldsboro, NC
Parts Used:
5303917590
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
Deforst Drain Pan rusted out
The old drain pan had a 1 ½” tall bushing attached to the center of the pan. The new pan did not have this bushing which was great. I had to cut about 1 inch off the bushing to remove the old pan. Also after cutting the bushing I had to screw the bushing off after cutting the old pan from the bushing. I installed new pan onto the ½” of threads that was left on the top of the compressor. Checked repair two days later all was great.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Rapid City, SD
Parts Used:
218906802, 316538904
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
My Frig Light Stopped
I am a 65 year old woman with no mechanical aptitude: I just unplugged the frig. And used a screw driver to pry of the plastic socket from its outside edge. . Then you just unplug two tiny contact plugs that appear when you pull out the socket and replug in those two the same way on the new part. Pop the socket back into the hole . . . . And screw in the new bulb. I knew I needed the socket part cause when the bulb burned out , a new bulb still did not work. . . If I can do it, anyone can!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Armando from Eagle pass, TX
Parts Used:
5300158289
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
the evaporator fan same time won't stater
change the evaporator fan motor kit working perfect
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Hoopeston, IL
Parts Used:
215846604
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Defrost Timer Stuck On Defrost (Again)
I went online to a you-tube video to assess the problem and watch the repair. Ordered the part on sunday before christmas and had it christmas eve! Easy 10 minute repair. Four screws held the cover on. Two screws held the timer. Unplugged the old timer an replaced. Put all the screws back and . . . . Done! Easiest repair I've ever done. Parts select did a great job, good price, very fast service! One happy customer!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from New Ringgold, PA
Parts Used:
5300158289
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Replace evaporator fan motor.
Replace evap fan motor. Take a close-up picture of the evaporator fan motor installation prior to removing. Take pictures as removing various components.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rochelle from Big Lake, MN
Parts Used:
5303324302, 3206150
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
door shelf end cap hooks broken
Previously I glued them on with epoxy and Taped them. Often redoing. So I needed to clean the surface with goo gone. And to clean out the slots I used a utility knife. I had a small bump on the new end cap so I removed it with the utility knife. Simply put the end caps on the rail on each end. Then put the hooks in the slots and slide downward until it is secure. I should have thought of parts before! When the rail broke off I had cherries in a jar on that shelf. It crashed to the floor. I had a sticky mess every where.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from White city, OR
Parts Used:
3206165
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
fit was perfect
replaced broken end cap
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gregory from Alexandria, MN
Parts Used:
3206166, 3206165
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
I inherited this old refrigerator as part of the space where I now live. I found the bottom shelf bar for the door tucked away under the sink, but there were no brackets. I'm sure they were broken and discarded at some earlier time.
I snapped the brackets into the ends of the shelf bar, then inserted them into the holes in the door and pulled down each end until it snapped in place.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Hicksville, NY
Parts Used:
215846604
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Fridge section not cold enough, Frost in freezer
Very easy to do, as per the video instructions.
Was this instruction helpful to you?
Thank you for voting!
Customer:
BILL from GENOA, WV
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 2539305311