Janet from Hillsboro, OR
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
24 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
HAROLD from SPRING HOPE, NC
Parts Used:
WPW10169511
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
motor coupling weld broken
Removed four screws from ice maker motor/light support.Then unplugged electrical plug from side of freezer.Used two slip joint pliers to remove coupler from motor shaft. installed new coupler to shaft hand tight as will tighten as motor is run.Then reversed tear down order.
Ice dispenser works better than when we first got the refrigerator
24 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Sandy, UT
Parts Used:
W10823377
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Ice Door would not close
I removed the Ice door front cover on freezer door. Found door pivot was broken. I installed door pivot bracket, and dashpot in kit. I used most of the kit to repair it. The door now works like new. Thanks for the right parts Frank
26 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Florentino from Windsor Locks, CT
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Westlake, OH
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
refrigerator was intermittently cooling because thermostat contacts burned away.
Turn off the fridge and unplug the power. Inside the refrigerator unit, remove two plastic panels extending from the front to the rear cooling vent by unscrewing two screws. Gently unhook the thermostat tube from the rear vent.

On the control panel, gently pry off the two control knobs and the front control panel. Remove four screws to drop down the control assembly. Unplug the left electrical connector and unscrew the lever control arm being careful not to bend it. Disconnect the right side electrical connector and you can now remove the control unit to a table to easily work on it.

Undo two screws to remove the thermostat bracket. Undo two more screws to remove the thermostat assembly. Install the new thermostat and reverse the process just described. It takes about 15 minutes if you know what to do ahead of time. You will have to reuse the plastic tube that covers the thermostat sensing tube.
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jay from Oconomowoc, WI
Parts Used:
WP2182179, WPW10329686
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Refrigerator door fails to close on its own like it is designed to.
The design of this refrigerator door (it's a side-by-side) is somewhat unbelievable. The door is designed to hold things, yet when you do the weight of the door wears out the lower door cams. The cams are designed to "complete the door closing", i.e. when you gently push on the door the cam mechanism takes over. When the cams wear, the door fails to close. Note to others - you may mistakenly think that the failure of the door to close is related to the seal; it is not.

The repair is quite easy; remove the upper cover, using a not driver (socket), then remove the upper door bracket. Make sure you hold the door or have someone else hold it. After the fasteners are removed gently lift up on the door and remove it from the lower cam assembly. You will see two plastic cam pieces; one on the lower bracket and one on the door. Both need to be changed to effectively "renew" the door closing mechanism. Once the cams are replaced the door can be reassembled to the refrigerator.
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
McManus from Palm Coast, FL
Parts Used:
W10408179
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
No water to icemaker
Unplug refridge, shut off water supply, remove backing. Remove two screws holding in valve, pull out valve and remove water lines. Have towel to wipe up very little water that leaks out. Unplug electric sources, remove old valve. Take new valve , plug in electric sources, push in water supply until they bottom out, attach bracket to back of refridge. Replace backing, turn on water supply, plug in and bleed lines.
27 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laurence from Middleton, WI
Parts Used:
W10190935
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
plastic gear broke off - cubes not getting kicked out
removed the three screw holding the broken unit - pulled off the old module.

Before I could install new module I had to loosen some fasteners on ice maker so I could turn shaft to align with new module.

Then push on new unit and three screws. Had tumbling ice in about an hour. My wife thinks I'm a hero. (I am)
23 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Greeley, CO
Parts Used:
WP2182181, WP2182179
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Refrigerator door failing to close without being pushed shut
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
25 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
W from Nellysford, VA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason from Farmland, IN
Parts Used:
WP2188664
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken drawer
Put new drawer in fridge.
22 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
haig from La Quinta, CA
Parts Used:
WP4388152
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Wrench set
in door water dispenser tube broken off 1.5 inches from end
shut off water supply behind fridge then released trapped water pressure in the line at the dispenser. Locked off dispenser controls (push button switch). Removed nozzle retaining screw and pulled out nozzle approx. 3 in. to cut off tubing at black pipe so as to use the old pipe as a guide/pull (fish) for the new pipe by joining the end of the new nozzle to the cut and of the old pipe with electrical tape.Then pulled the old pipe from bottom of fridge while simultaneously feeding/pushing new pipe from top. I had to remove lower grate on fridge to access the pipe on bottom. Remaining coupling connection on bottom was done by hand to avoid stripping plastic coupling.
23 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Murfreesboro, TN
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Fridge side freezing everything.
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control box to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
21 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barb from North Royalton, OH
Parts Used:
2188405A, 2188404A
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Refrigerator came with house my daughter purchased and needed new seals. Refrigerator is 17 years old.
First, I read your instructions on line about how to replace a refrigerator gasket and freezer gasket. We replaced both. The information was extremely helpful since we had never done this before. We then loosed a few screws at a time starting with the outside door corner and worked our way around, replacing the seal as we took off the old seal. Leaving the old seal on as we worked our way around gave us the clearance we needed to insert the new gasket behind the metal plate which holds the gasket to the door. Your easy to use web site made ordering easy and delivery was unbelievably fast. Thanks.
23 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Winston-Salem, NC
Parts Used:
W10823377
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
ice distribution door broke
At their site was ordering each piece by # and cost and it was adding up to be costly. Went to partselect and was doing the same and up pops the ice door kit. Was a little wary because my original had a heater tape to it. Got the kit and installed not a problem at all. 100% satisfied would recommend to anyone.
23 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10659092990