- Customer:
- Jennifer from Schertz, TX
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Contact in thermostat assembly was burned up, making the freezer irregular and the ice would melt, then freeze into a ball!
I took off the front cover with the controls. Pulled out the control knobs, unbolted the assembly (which was identical to my replacement part) and proceded to follow the old thermostat tube to the back of the fridge. The tube should be carefully removed, not pulled on, there's a couple of screws holding it in towards the back. I installed the new part in reverse of how I took out the original part. I'm very happy with how the fridge has come back to life! It was much cheaper to fix it than to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Rocky River, OH
- Parts Used:
- WP627985
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Screw drivers, Socket set
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Gurnee, IL
- Parts Used:
- 4389144
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Motor intermittently not working.. Warm Frig.
Very easy. Take panel off and replace motor.. All wires matched fine. Easiest applance repair I've done..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joe from hilliard, OH
- Parts Used:
- WPW10190929
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker leaked into ice reservoir
The ice mold has a coating on it. Over time the coating deteriorates. If your ice maker leaks water into the ice reservoir inspect the mold to see if the coating is compromised. If so, replace with new.
Remove the ice maker assembly. 3 small hex screws. Unplug power cord. Disassemble ice maker assembly. Remove ice mold/heater. Replace with new. Reassemble.
Remove the ice maker assembly. 3 small hex screws. Unplug power cord. Disassemble ice maker assembly. Remove ice mold/heater. Replace with new. Reassemble.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Melvin from OPELIKA, AL
- Parts Used:
- W10823511
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
35 year old water tube became brittle and cracked; leaking water
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randal from Wakefield, RI
- Parts Used:
- 4317943
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice getting stuck, and water flowing over everything
The on-line video and the hard-copy instructions with the replacement part made it very easy. Just loosened the 2 upper screws and took out the bottom one. Eased the ice maker out a bit and disconnected the plug at the back (power was off). Checked the replacement part had exactly the same wiring harness - it did. Fitted the bail arm from the old one. So simply did the same process in reverse. So 15-20 minutes after I started, the job was compelete. It takes a while for ice to start coming, but it did, and after 24 hours I threw out the ice and started again to make sure the ice came from fresh water.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- timothy from indio, CA
- Parts Used:
- WPW10190929
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Mold Ice Heating Element Broken
Looking at the ice maker it is pretty cut & dried as to how to remove the unit. I took out the ice tray and just started removing all the mounting screws. The same for the mold ice tray & heating element. I was just sad that you did not have just the heating element separate from the mold ice tray.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Harahan, LA
- Parts Used:
- WP4388152
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
water nozzle was cracked and leaked
I removed the screw holding the nozzle in place, and removed the other end of the line under the refrigerator to give me some slack. Then I clipped the nozzle off of the black line and taped the new line to the end I cut off with electrical tape. Then I just snaked it down through the hole with me pulling from the bottom and my wife pushing from the top and reattached both ends. Make sure you don't use too much tape becaue it won't fit throught the hole at the bottom. I taped them together at an angle so not to make tape too thick. Also, you can snake it back from the bottom if the tape breaks and the old line comes out of the fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- anthony from georgetown, IL
- Parts Used:
- WP628356
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Broken Piece
Had to disassemble ice maker to install part. . .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STEPHEN from FENTON, MO
- Parts Used:
- WPW10225581, W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer No Longer Cools
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Was this instruction helpful to you?
Thank you for voting!
Icemaker Wouldn't Work
I removed the screws that attached the drum housing to the bin. I detached the auger & removed the broken drum assembly, turning the auger to the right, opposite what I thought it should be. I slipped the end of the auger into the new bin coupler & put it in place at the rear of the bin. Next I slipped the auger drum into place & tightened it to the left with a socket wrench. I screwed the drum housing to the bin, put the bin back into the freezer & I now have ice through the door again. Easy repair even for me, a 60+ woman.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Indianapolis, IN
- Parts Used:
- WP2187464
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
no power to the ice maker
The wiring harness was a straightfoward plug in replacement after depressing the securing tabs, and did provide power to the icemaker. However, the icemaker would continually cycle, with the mold heater on at all times. I suspect this is what caused the thermal fuse to blow in the first place. Rather than spend more time replacing individual components, I eneded up replacing the full ice maker assy. The new ice maker works properly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from Milford, OH
- Parts Used:
- W11342242
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker was over producing
Technician at ASK suggested replacing ice maker. Ordered new ice maker(prompt delevery)then noticed it came without wire arm and white platic "flag". Ordered arm and "flag", replaced all old with new and seems to be doing well. Perhaps all I needed was the plastic "flag" on the limit arm wire. Will never know. The new icemaker wiring had short wires and a connector. Old ice maker had no connector so the short wires were removed and the old wires plugged into the ice maker. Mirror was required in order to see the side wall mounting screws. Very narrow work area, tiny freezer side.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sheila from Lena, MS
- Parts Used:
- 4388736
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would no longer move ice through the dispenser
As cookbook authors and publishers, my husband and I depend on our appliances. When our icemaker would no longer work, it was imperative that we repair it as quickly and ecomonically as possible. We had used PartSelect.com earlier to order a part to repair our Jenn-Air stove top and had great results. So, rather than paying a repairman four times or more the cost of the part, we ordered the part and my husband installed it. It took less than 30 minutes to remove the broken auger and install the new one. THANKS PartSelect.com -- we'll use you for all appliance parts needs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Troy from Kansas, OK
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezer wouldn't defrost/low temps in refrigerator
Found the housing for the thermostat; took housing apart pulled out thermostat and took off the hose put the hose on the new thermostat installed new thermostat and replaced housing.
Was this instruction helpful to you?
Thank you for voting!