1069430211 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- roberto from san Antonio, TX
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
freezer gets too cold then gets to regular tempetured
disconect the power removed the screws with the phillips screwdriver removed the front cover and then removed the rest of the screws. removed the three covers and then removed the thermostat. replaced in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Herndon, VA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Lewisville, TX
- Parts Used:
- WPW10329686
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Socket set
Refrig Door Cams wore out and made noises when opening and closing.
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two year old Frig. This is a design problem, as the cams should last longer than 22 months.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Choctaw, OK
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from Eaton Rapids, MI
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
The frig/freezer shut off too often and would not stay cold.
The new thermostat assembly installed quite easily, just a couple of screws, but the thermostat probe however was kind of a pain in the rear. The probe is about 3 feet long and you have to remove a plastic sleeve from the old part and re-install on the new probe, it fits very tight and takes some time to do. Overall it was a very easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Martinsville, IL
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator had shut down
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Chagrin falls, OH
- Parts Used:
- 4318165
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
door would not stay closed
Removed the top plastic hinge cover, remove (2) bolts from top hinge. Lifted door up and off of lower hinge, removed both halves of door cam, replaced cam halves and re-installed door. Super easy and effective. Door now opens and closes (stays closed) properly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Olesya from ORLANDO, FL
- Parts Used:
- WP2198202
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refregirator would not turn cooling back on after shutting down.
After spending $250 on repair by calling appliance repair professional who changed relay in the fridge, the problem was not solved. I had to manually turn the switch off and on again to make sure my fridge would maintain its temperature. I read some similar problems on this web site, watched instalation video and decided to give it a try. Part came in very quick and it took me (female) 45 minutes to install the new part and refregirator worked like a champ. I would never call professional again until I try fixing the problem myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STEPHEN from FENTON, MO
- Parts Used:
- WPW10225581, W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer No Longer Cools
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Arlington, TX
- Parts Used:
- 4387478
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Ypsilanti, MI
- Parts Used:
- WP2155476
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
broken kickplate
just snapped it on,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Roanoke, VA
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Olympia, WA
- Parts Used:
- 4388538
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
The flat support part of the stud had broken off, and I had removed the part to try to find a replacement. So, the shelf that holds one of the drawershad no front support on one side.
I removed the drawer and the shelf. I looked at the support on the other side to figure out how to insert the new one. Due to the shape of the "hook" part of the support, and the hole it needed to go into, I figured out which way I needed to insert it to be able to twist it so it would stay in place. From another online hint, and from talking to a repairman at a local shop (who had ordered me the wrong part) I knew I needed to twist it after inserting it. I used a pair of pliers to twist it counterclockwise, about a 3/4 turn. I put the shelf in and re-installed the drawer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Sherman Oaks, CA
- Parts Used:
- WP1114687
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
3 years ago, we broke the shelf
When we moved into the house, we cleaned the fridge and broke the glass shelf and thats how it has stayed.Then I finally got over my fear of ordering things "online" and within a week, we had a new shelf which just slid into place.
The shelf was packaged so well that even the UPS guy throwing over our locked gate didn't break it.
Thanks Part Select....job done !!!
The shelf was packaged so well that even the UPS guy throwing over our locked gate didn't break it.
Thanks Part Select....job done !!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dana from Canyon Lake, TX
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
Was this instruction helpful to you?
Thank you for voting!