Models > 1069545580 > Instructions

1069545580 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 1069545580
1 - 15 of 840
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Daniel from Suwanee, GA
Parts Used:
W10190935
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
No ice
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.
558 of 666 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
garth from forest lake, MN
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
My refrigerator stopped cooling and the freezer section stopped freezing
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
395 of 475 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve earney from Brooks, GA
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
inconsistent compressor and condensor fan operation
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then not cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...
305 of 320 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from Winter Park, FL
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
154 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Port Washington, NY
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ice Maker stopped working
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.

Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)

However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part.

Unscrewed the motor assembly (3 screws) with phillips head screw driver.

Screwed in the new unit.

Placed ice maker back into location and tightend the bacing srews.

1 hour later ice was falling!
135 of 154 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Orland Hills, IL
Parts Used:
WP2196157
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Broken elbow on icemaker water fill tube.
Removed 2 screws holding water fill tube to rear of refrigerator and pulled out, matched old part with new to make sure of proper match. Guide new fill tube thru hole, making sure it is aligned with slot in ice cube tray on inside of freezer. Install new plastic line from water pump outlet to water fill tube, check for leaks, job done.
130 of 141 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from clarksville, TN
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The compressor would shut down and not restart unless you tapped the temperature knob which i did for about 3 weeks before ordering this part
Was pretty simple just take the knobs off pull off the face plate remove a few screws and drop the whole shelf down. then a few more screws down the side to the back of the fridge. Pull the sensor wire out of some styrofoam and pull off the plastic coating and slide it over the new one and install it in reverse order from taking it out. Works great now and i have ice everyday :)
116 of 121 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Chester, CA
Parts Used:
WP628356
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
107 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Antoni from vail, AZ
Parts Used:
4389144
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
evaporator fan stopped working
1) removed the face plate that runs 3/4 way up the back of the freezer side. a total of 8 screws. (6")
2) disconnected the three electrical connections.(30sec)
3) removed the fan of the the old evaporator fan motor (5sec)
3) removed the fan motor (1")
4) put in the new fan motor (1")
5) put on the old fan on the new fan motor(5sec)
6) reconnected the three electrical connections (30sec)
7) replaced the face plate on the back of the freezer (6")
Had re-frozen meat within 1 hour.
95 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eddie from Gretna, LA
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Refrigerator was not cooling properly.
I removed both plastic knobs from assembly faceplate. Then I loosened the screws holding thermostat housing to upper cabinet of fridge. Following this step, I loosened the screws of the thermostat to remove it. Next was the removal of the plate and vent pieces holding the thermostat wire sleeve in place. After removal of thermostat from sleeve; all steps were reversed and unit was up and running normal (cooling) with no problems. "Ahh, it's nice to have cool again "
73 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ryan from Layton, UT
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Icemaker made a clicking noise then quit making ice
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.

Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.
77 of 96 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wayne from Leesburg, FL
Parts Used:
WP627985
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
No ice in ice trey
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.
78 of 100 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Pavel from Norwalk, CT
Parts Used:
4388538
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers
The studs to hold the shelf were broken
The hardest part was to figure out how to remove the old studs and put in new ones. I figured out finally that they should be twisted out and in., Simple online or printed insruction would be very helpful. Unfortunatelly the manual does not contain any repair information.
I fixed it with little trouble.
67 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LES from MADERA, CA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Defrost timer was faulty. Required a mild tap to restart
Trouble shot the electrical circuit per the electrical schematic and zeroed in when I noted the Defrost Timer circuit was open. When I tapped on the bottom of the timer it began functioning normally (for a few days). Ordered a new Defrost Timer Kit and along with the installation instruction, I watched the on-line video. It was very helpful!!
After installation was complete, I plugged the Refrigerator into the electrical outlet and.......nothing happened! Hmmm!

Removed the Defrost Time Kit and inspected it for any damage and found none. Then I placed a flathead screwdriver to the manual advance knob and slightly rotate the gear mechanism. I heard a distance "click”. I believe the Timer was in the ‘defrost’ mode when received.

I reinstalled the timer, verified the wiring connections and this time plugged the Refrigerator into the electrical outlet and ….. it worked!!!

I unplugged the refrigerator, finished the installation per the instructions, plugged the unit in and monitored it for a few hours (just in case). That was a week ago and the Refrigerator is working like new.

The instructions were written in a manner which required re-reading a few times as they could be a bit vague. The video was what really helped and I appreciate PartSelect adding it to the instructions.
66 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Elgin, TX
Parts Used:
W10190935, WP627985
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice maker not initiating harvest cycle (not making ice)
My troubleshooting narrowed down the problem to either the control assembly or the thermostat, so I bought both just in case. The motor assembly fixed the problem and I didn't need to install the thermostat.

The main thing I want to tell others who are doing this repair, however, relates to the thermostat. If you do indeed need to replace the thermostat (#PS380941) there is something you will need that is not included with the part or mentioned anywhere on this site. The instructions with the thermostat indicate you need to apply something called "Aluminastic" to the thermostat when installing it. I don't know about you, but that isn't something I have around the house, so be sure to order a tube of it when you get the thermostat so you don't have to take a trip to the store to get it to finish the repair.
66 of 74 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 1069545580