Doug from COPE, CO
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Refridgerator stopped making ice
Removed the old water valve from back of refrigerator by using a screwdriver. Pulled water line off old valve that runs into the fridge and inserted it into the new part. I used a pair of pliers to take off water line that runs into the water valve from the house. Screwed the water line back onto the new valve. Took about 10 minutes.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Riverdale, NJ
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water leaking and freezing everywhere. Weird shaped ice cubes, more like chunks which jambed the dispenser.
First removed the two screws that holds the old ice maker in place. Unplugged it. The freezer compartment was too narrow to allow the unit to slide out or turn in any other direction. Had to also remove the two front screws from the left side ice bin track and swing it down. The door opening was also too tight. Scratched the plastic door jamb putting the new unit in but other than that all is well and functioning well.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Irma from Tylertown, MS
Parts Used:
WR17X2769
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The front of theDrawer Slilde Rail broke off the rail.
Removed the 2 drawers and then the glass shelf.
Positioned the drawer slid and tightened to rear screw and the front screw.

Replaced the shelf and the 2 deawers.

What's the big deal? Any 78 year old woman can do it.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Palatka, FL
Parts Used:
WR17X2769
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Bracket was broken near the front mounting location causing the rt drawer
First i removed everything from the bottom shelf, removed the glass, then removed the entire bracket assembly. Then removed the front metal strip to expose the front mounting screw, then removed the rear screw. Installed the new part and reversed the procedure.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eli from Buford, GA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker
Remove ice maker out of fridge; remove 3 screws
replace defective part re-install all components 30 minutes later " magic ice again. Very easy repair most important low cost. Thanks "Parts Select"
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randall from Cumming, GA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Wrench set
Water valve for ice maker leaking
Other than having to bend the bracket 90 degrees it was an easy install.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Margaret from Virginia Beach, VA
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Ice maker would only make very small and very few ice cubes.
After determining that the ice maker on this relatively new refrigerator would make ice cubes if it received the proper amount of water. Ordered the valve and received in a couple days. Using a nut driver, removed the cardboard cover from the back of the refrigerator. Removed one screw holding the valve bracket to the fridge and removed another screw holding the water supply line and the water line to the ice maker in place. Pulled plug on fridge and removed 2 wires from valve. Removed inlet and outlet lines from old valve and reversed the process installing the new valve.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cliff from ROCKVILLE, VA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench set
The old solenoid was slow to shut off causing the icemaker to overfill.
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the back panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
T from SOUTHBURY, CT
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Original evaporator fan (31 years old) was making a lot of worn bearing noise
Empty freezer;
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.

I did have to use the wire extensions that were included as the replacement motor had the electric connections in a different location from the original motor.

Overall, this was an easy replacement.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from VERO BEACH, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
The Refridgerator and Freezer were not cooling.
Installing the part repaired the fridge and freezer immediately.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paul from ENDICOTT, NY
Parts Used:
WR55X24064
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
freezer stoped freezing
my freezer quit freezing, it would freeze for one day, thaw the next, so I went online, found PARTS SELECT, LOOKED UP MY MODEL #, come to find out it needed three parts to keep my freezer to freeze, first part was a thermistor a small PART took me longer to remove all the covers, and shelving, PULLED THE OLD OUT, CUT THE WIERS TO SIZE, AND REINSTALLED, IT WELL! THAT WASN'T ENOUGH THE FREEZER STILL DIDN'T FREEZE IT THOUT IT WAS A COOL WORMING OVEN, HAD TO INSTALL THE THERMISTOR I, SO I DID, TEN MIN, NOW I THOUGHT THAT WAS IT BECAUSE IT STAYED FROZEN FOR A WEAK, HAVE YOU EVER EATEN SOUPY ICE CREAM? SO BACK TO PARTS SELECT, THIS TIME I BOUGHT ONE MORE PT, THE RUN CAPACITOR, FIVE MIN, THAT/S ALL IT TOOK TO INSTALL. I DID NOT KNOW AT THE TIME YOU NEED THE THREE OF THEM TO RUN THE FREEZER ONE TO KEEP THE TEMP., ONE TO KEEP THE FAN RUNNING THE WAY IT SHOULD, AND THE THIRD TO MAKE SURE THE OTHER TWO KEEP RUNNING. NOW I CAN SET IT AT 4- 5 AND. FREEZE.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from FLUSHING, NY
Parts Used:
WR60X10168
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The freezer just cool but could not freeze the water and the front of door is quite hot to touch.
First I observe that the compressor motor is running since the freezer is cooling. The purchase of the condenser fan is initiated and when the part arrive it is just easy to reinstall the replacement condenser fan.

The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.

The refrigerator as of now is running in perfect condition!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hugh from LADSON, SC
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice Maker stopped making ice.
Did the repair just as the instruction said, once I read it. The part I didn't read was that if the plug was under the ice maker, you had to take the wire out of the clip on the side. So, had to dismount ice maker, unclip wire, remount maker, plug it in. Still under 30 minutes. Thank you.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from Vicksburg, MS
Parts Used:
WR9X520
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Wrench set
Water Leaking out of bottom of refrig first then out of vegetative bins underneath
Replaced defrost thermostat and defrost controller and also noticed that run capacitator for compressor almost oxidized in two and ordered and replaced and cleaned out drain tube and invertor (which was blocked by frozen peas and other food)or water to drain during defrost cycle and put everything back together and seems to work fine now....storing beer in outside refrig now
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ann from LAPORTE, PA
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
freezer too cold and refrigerator not cold enough because fan not working
Had to defrost a bit and then was able to remove rear freezer panel by simply removing the 2 screws holding it in place.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and red wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!