Richard from Norman, OK
Parts Used:
5300158289
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
fan motor worn out
Removed the old and installed the new. Electrical plug/socket made connection easy. Biggest problem is working space in freezer side of a side by side with the fan in the back. If I can do it anyone can.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gregg from Mohnton, PA
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Freezer frosted up
Removed old thermostat and replaced. really easy.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Scranton, KS
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Coils freezing up and refrigerator would get warm
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Success! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from Lithonia, GA
Parts Used:
5303917954
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Freezer was getting a build up of frost on the condenser and wasn't cooling.
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lisa from Los Angeles, CA
Parts Used:
5303270406, 216594300
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
refrigerator stopped cooling
After the refrigerator stopped cooling, we determined that the problem was in the compressor area. we used a screwdriver to get the cover off and then vice grips to get the actual pieces out (start relay & overload)--they broke, but they were already broken). We went to the Home Depot site to purchase the parts, but found PartSelect to be much less expensive. Put the parts in when they came a few days later and it worked! thank you PartSelect!
11 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brad from York, PA
Parts Used:
218730603
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Torn door gasket
Removed numerous screws, be careful removing old gasket to not crack door.
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fernando from La Grange, AL
Parts Used:
5303917954
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench set
freezer would not defrost
tested defrost timer and heater. And then tested defrost timer with ohm test($6 at hard ware store) Closed and would not open replace and tested freezer take 30mins to get switch cold and retest.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darrell from Bentley, ND
Parts Used:
5300158289
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
the evaporator fan quit when we had a power surge
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from CEDARTOWN, GA
Parts Used:
216594300
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Freezer would not run ... replace the compressor start relay which fixed the problem
Pulled out the freezer. Unplugged. No freezer back cover was there. The compressor start relay was in a plastic encasement attached to the compressor - wires led me to it. Removed the solid metal spring with a screwdriver and removed the plastic cover. Tried to pull out the defective relay but the freezer was so old I needed a pliers to remove it. When I put pressure on the old relay with the pliers the relay broke and came off in pieces. I then removed the wires from the broken parts and put them on the new relay. I pushed the new relay onto the 2 pins then replaced the cover and spring. After plugging the freezer in the problem was fixed.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ANGELA from MEBANE, NC
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Partlow, VA
Parts Used:
5300158289
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Motor squeal
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from BASKING RIDGE, NJ
Parts Used:
215846604
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator had not been cooling
Discovered the coil was covered with 1/2 inch of ice because defrost cycle had not been working. Replacing the defrost timer and melting ice with hair dryer fixed problem. Hooray!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from MANHEIM, PA
Parts Used:
218730603
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Seal was old and cracking allowing condesate to rust the door
I should have read everyone else's experiences before attempting. I did view a youtube video and thought I had it set. However, if I had it to do over, the door would have been removed. The door shelf (inner door) taken off and cleaned before attempting to put the gasket on. I did it while the door was still attached and probably lost a good 45mns along with my fingers cramping, knee's flat spotting, and lower back catching fire. TAKE THE DOOR OFF if at all possible, you wont regret it.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Damien from Oneonta, NY
Parts Used:
3206166, 3206165
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Easy Fix
Was really basic, simply slide off the old caps, slide on the new ones, put the shelf back where it goes, push down lightly so as to not snap the new caps, and viola, complete. No more than 2 minutes worth of work. Great part at a great price, shipping was more than the part itself so I bought 2 of each. Only problem I ran into was that I ordered the top shelf caps instead of the bottom the first time, so I had to reorder.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nell from New Orleans, LA
Parts Used:
5303324302, 3206150
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Door shelf retainer bar end caps broke off at insertion point.
Removed plastic male parts. Inserted new end caps onto old retainer bar. Inserted all into door. A snap, but I didn't need to order the retainer bar after all - the old one was the perfect fit and the one I ordered was way too long. I returned the new retainer bar, and the shipping was more expensive than the part.
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?