10662144207 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Steven S. from Kerrville, TX
- Parts Used:
- WP2315576
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Leaking water inlet valve
This would have been a less-than-5-minute repair except for one item. The water intake nossle was 180 degrees from the original part. As a result, the copper water inlet tube would not fit in the old space and still allow me to reattach the valve to the freezer chassie. I ended up leaving the valve hanging loose under the freezer. I spent most of my time trying to fit the valve into the old space.
Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.
Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished
Everything works just fine !
Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.
Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished
Everything works just fine !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Drew from mountville, PA
- Parts Used:
- W10124096
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Dead condenser fan/motor
Replaced the entire unit (fan and motor). Would have rated this repair as "Really Easy", but found it a little difficult because of large hands.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Matthew from Miller Place, NY
- Parts Used:
- WP2304099
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
no auto defrost
Quoted $275 to fix, paid $65 for the part , Installed the new part in about 15 min. very easy, removed 2 small screws, and plugged in new part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Spring Valley, MN
- Parts Used:
- W11700559
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench set
installed ice maker
From the time I started to finish I worked 3 hours, this included installing the new ice maker, cutting into the cold water line in the basement and installing a t with a 6inch piece of pipe with a compression valve to connect to the small cooper tube, this is worth your time to do it this way, its a lot better connection than the small pierce valves that come with the kit, they will leak over time. I installed the filter in the waterline in the basement for easy access
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Britney from Wilmington, OH
- Parts Used:
- W10124096
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Loud noise
There was a loud noise coming from the fridge - we ordered the new part it came a lot sooner than we excepted and we replaced it in about 20 minutes- the hardest part was my husband getting his hand in there to put the screws in- but a very easy fix.
Was this instruction helpful to you?
Thank you for voting!
Replaced Freezer Door and Refrigerator Door Gaskets
!st removed the doors from the unit, then laid them on the floor. Next, on a long side of the door, cut through the gasket so I could pull it off the door in one piece without separating the door liner from the outer door. Then, starting at a corner, started pushing the stiff black part of the replacement gasket between the liner and outer door, making sure to push it completely under as I went. Used a thick flat bladed screwdriver to carefully help push the final corner section in. Repeated on both doors, rehung, plugged in and done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joyce from Kerrville, TX
- Parts Used:
- WP2195916K
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Didn't know if I needed Left or Right.
The item is listed as R, meaning right hand side. If you need it for the left hand side, simple turn it over. It is designed to work on both sides of the door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROBERT from BUENA PARK, CA
- Parts Used:
- W11700559
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
Wrong electrical connector.
I bought a new Whirlpool Refrigerator that didn't have an ice maker.
I wanted to install an ice maker. I searched your web site and found the model ice maker model it said I needed. WPW10715709. This one was a 4 wire 8 terminal. I needed a 4 wire flat connector. WPW10715708. You approved the return. It cost me $50 to return it. I believe you should refund me the cost of this postage. Your web site gave me the wrong model number.
Thank you
I wanted to install an ice maker. I searched your web site and found the model ice maker model it said I needed. WPW10715709. This one was a 4 wire 8 terminal. I needed a 4 wire flat connector. WPW10715708. You approved the return. It cost me $50 to return it. I believe you should refund me the cost of this postage. Your web site gave me the wrong model number.
Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- martin l. from JACKSONVILLE,, IL
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lisa from Fort Myers, FL
- Parts Used:
- WP2218132K
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
I cracked mine :D
Slid right in...exceptionally easy :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harald from Cape Coral, FL
- Parts Used:
- W10854037, WPW10421486, WP2156006
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken parts in refrigerator
Replaced with new parts
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lori from Chuluota, FL
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Medway, MA
- Parts Used:
- W10190935
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker motor would run continuously but the blades would not turn and no ice came out.
I wasn't sure what the problem was, but the ice maker seemed simple and on-line resources suggested the control and motor assemblty was at fault. I searched the internet and Partsource had great diagrams which I could match to the part in hand. The price was right (way less than the local stores) so I ordered it.
I unplugged the unit from the power in the freezer, but unplugging the entire refrigerator works too. I pried off the white cover on the front of the ice maker, which snaps in place top and bottom. There are three screws holding the contoller (the entire front piece), remove them, pull off the controller and push the new one in place. You may have to turn the blade shaft to line up the notch on the shaft to the motor. Then reinstall the three screws, The screws go into plastic so it is easy to cross thread them, so be careful, I actually think I did with no ill effects. Snap on the cover and repower the unit. Done. Simple and quick.
I unplugged the unit from the power in the freezer, but unplugging the entire refrigerator works too. I pried off the white cover on the front of the ice maker, which snaps in place top and bottom. There are three screws holding the contoller (the entire front piece), remove them, pull off the controller and push the new one in place. You may have to turn the blade shaft to line up the notch on the shaft to the motor. Then reinstall the three screws, The screws go into plastic so it is easy to cross thread them, so be careful, I actually think I did with no ill effects. Snap on the cover and repower the unit. Done. Simple and quick.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Rocky River, OH
- Parts Used:
- WP627985
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Screw drivers, Socket set
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Craig from Rockledge, FL
- Parts Used:
- WP4387503
- Difficulty Level:
- Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver
Ice buildup on the bottom of the freezer, water dripping into the refrigerator
After unplugging the refrigerator, I used a hairdryer to melt the ice sufficiently to be able to remove the freezer rear panel with a nutdriver. I also removed the ice-maker for easier access to the components behind the panel, using a nutdriver. Once the panel was removed I melted more ice at the bottom of the evaporator housing. After partially melting the ice in the drain tube, I poured hot water down the drain tube until it cleared, signaled by the sound of the water dripping into the drain pan. I next removed the clip-on Bimetal thermostat from the copper line going into the evaporator and snipped the two wires to remove it. I installed the replacement thermostat with crimp-style connectors and pull-tested them. I also replaced the timer board that is located below the freezer, below the top shelf, using a nutdriver. I replaced the circuit board as a precaution that the thermostat may not have caused the problem. I didn't change the heater inside the freezer as it checked out to have the same resistance as a new one. I tested the removed thermostat using a glass of ice water but it remained in the open condition, using an ohmmeter. (I later checked that thermostat after the freezer was running and it did close, and returned it to the open position by heating it under the hot water faucet. I suspect that it didn't work properly, or the timer control board was faulty). After re-installing the back panel and ice-maker and plugging the refrigerator into the power receptacle, it worked very well, and has done so since the repair.
Was this instruction helpful to you?
Thank you for voting!