Models > 1069452310 > Instructions

1069452310 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 1069452310
16 - 30 of 467
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Jon from Houston, TX
Parts Used:
4389144
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Excessive noise was coming from the freezer section of my side be side refrigerator
Cleaning out the freezer took the longest time. Once the freezer was clean I turned off the freezer which did not deactivate the light in the freezer. This is a tight area to work in and not having to hold a flashlight made the job much easier. I then removed the shelf slider brackets for the 3 lower pullout drawers. The next step was to remove the interior aluminum back panel (6 screws) which covers the evaporator motor and the coil. Before removing the 3 electric wires that are attached to the evaporator motor make sure the power is off to the motor. The removal of the motor was fairly straightforward and I would suggest removing the plastic fan blade first and then the connector wires. It helped knowing in advance that the plastic fan blade would come off with a little prying. Be careful when prying the fan off so that you don’t damage the plastic motor mount bracket. Once you have installed the motor I would suggest turning the freezer back on to make sure that the evaporator motor works before reinstalling the aluminum back panel and slider brackets.
43 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Plano, TX
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Timer "clicking", indicating worn gears
1. Unplug refrigerator to remove power!
2. The timer is inside the control housing located at the top of the refrigerator compartment.
3. Remove two control knobs (the pull off).
4. Remove the front panel escutcheon. The panel is not held in place with screws, but can be gently pried off.
5. Remove two screws from the back that hold the housing in place.
6. Remove screws from the front that hold the housing in place.
7. Drop housing down (still attached by wires - do not detach). Timer is inside housing, located on right.
8. Follow the instructions provided to identify your particular wiring setup. You'll find the wiring diagram (on my model) at the bottom of the refrigerator, alongside the defrost catch pan, behind the airflow grille.
9. Remove connector from timer terminals (4).
10. Remove two screws/nuts that hold the timer in place.
11. Install replacement timer following included directions. Read and follow ALL instructions applicable to your particular model and wiring setup.
12. Reassemble by reversing the steps above.
13. Note: You may need to "jog" the replacement timer when you first plug the refrigerator back in, if the timer happens to be in a "defrost cycle" (the compressor won't start). This can be done by inserting a wide bladed screwdriver into the hole below the timer, aligning it with the timer shaft, and slightly turning the shaft CW. Don't force it, and don't turn it very far.
38 of 43 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James Richard from St. Cloud, MN
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
48 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Ringoes, NJ
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat. Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James
38 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Doral, FL
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
38 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherry from Colorado Springs, CO
Parts Used:
4388538, W10864399
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Glass Pan Cover / Shelf Broke
First of all, here's a warning to all -- I took the glass shelf / pan cover out to clean it -- with a sponge wet with COLD water and the shelf literally exploded on me. This is the second such incident. Both times I have been lucky and no one was hurt.

The shelf was easily identifiable by part number based on model number. Easy to locate the model number on plate above top shelf inside refrigerator (right hand side in my case).

Only had to carefully set glass shelf in frame -- no issues. I was able to use a screwdriver to remove the shelf support stud and basically pop the replacement back in with no issue.

Thank you Parts Select for your simplified system to order replacement parts, and the speed with which it was received.
32 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from Belleville, WI
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Our six year old fridge would not stop running - everything was frozen. Found if I tapped on the Tstat I could sometimes get it to turn off.
Remove the knobs and faceplate to get at the screws behind it. Removing the sensor is a bit involved but everything else is fairly straight forward. See other postings for description / order of operation. Replacement took less than 30 minutes.
Works great now!
29 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ed from Frankfort, IN
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Defrost timer was faulty. It would not restart on it's own.
Just removed the old timer and attached the wires to the new one and replaced the old. That simple!
33 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Albany, OR
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
36 of 56 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
M from Lafayette, IN
Parts Used:
W11700559
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
REplaced ice maker
Replacement was very easy as new ice maker was identical to the old one. Took about 10 minutes.
30 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Leesburg, FL
Parts Used:
W10508993
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Shelf Bracket
Removed food itmes on broken shelf. Removed old glass shelf cover. Removed broken shelf bracket. Installed new shelf bracket. Intalled new glass shelf cover. Replaced food items back on shelf
26 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
edna from las vegas, NV
Parts Used:
4388538
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Shelf support stub for crisper broke
I had read here from someone that fixed there shelf support stub and it was very loose, so I was trying to advoid that problem. It took me less then 5 minutes and my only tool was a pair of pliers. A short turn clock wise from the 9 on a clock to the 12 ( which is the top left corner ). then pull the broke shelf stub straight out. Put the new shelf support in the same way you took the old one out and turn counter clock wise 1/4 or from 12 back to 9 and you should have a tight fit. I hope this helped.
24 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Westlake, OH
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
refrigerator was intermittently cooling because thermostat contacts burned away.
Turn off the fridge and unplug the power. Inside the refrigerator unit, remove two plastic panels extending from the front to the rear cooling vent by unscrewing two screws. Gently unhook the thermostat tube from the rear vent.

On the control panel, gently pry off the two control knobs and the front control panel. Remove four screws to drop down the control assembly. Unplug the left electrical connector and unscrew the lever control arm being careful not to bend it. Disconnect the right side electrical connector and you can now remove the control unit to a table to easily work on it.

Undo two screws to remove the thermostat bracket. Undo two more screws to remove the thermostat assembly. Install the new thermostat and reverse the process just described. It takes about 15 minutes if you know what to do ahead of time. You will have to reuse the plastic tube that covers the thermostat sensing tube.
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Coppers City Bottom, WV
Parts Used:
4389144, WP2169142
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The fan wasvery noisy.
Removed six screws from cover in the back of the freezer. Removed old fan . Removed power wires from old motor. Unclipped old motor from the mounting bracket. Replaced old motor and reversed the rest of the parts. Done
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Murfreesboro, TN
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Fridge side freezing everything.
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control box to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
21 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 1069452310
16 - 30 of 467