1069334200 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- duncan from HOWELL, NJ
- Parts Used:
- WP2315576
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
old valve was not shutting off fully, flooding ice-maker, creating a glacier
Shut off water supply, removed old valve (two screws, 1/4' nut driver), disconnect electrical plug, remove water lines (adjustable wrench). Cut fitting off tube to ice-maker (new unit has a push-to-connect fitting). Replace water lines and electrical connector. Mount valve back on cabinet. Turn water back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Reinhold from Cheshire, CT
- Parts Used:
- WP2315576
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
No ice was being made
I looked up the refrigerator on the internet and found this website. I got the diagram of the parts of the icemaker and found that the valve must be defective because no water was coming up to the icemaker.
I ordered the part which came the next day. Took out the screws, conected the water line to the new part. moved the electrical connection to the new part and we had ice. Saved a lot of money that the plumber would have cost.
I ordered the part which came the next day. Took out the screws, conected the water line to the new part. moved the electrical connection to the new part and we had ice. Saved a lot of money that the plumber would have cost.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- phil from sioux falls, SD
- Parts Used:
- WP4387490
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer icing up
Freezer was running for extremely long periods I noticed and not doing a great job of cooling the fridge.I assumed it was in need of a defrosting so I took the panel off to take a look.
The whole radiator was covered with ice.I could see the defrost thermostat was half way popped out of its casing at a 45 degree angle.
I just had to cut the 2 wires to the defrost thermostat and wire nut the new one in.Very easy fix as the part just clips on radiator.
The whole radiator was covered with ice.I could see the defrost thermostat was half way popped out of its casing at a 45 degree angle.
I just had to cut the 2 wires to the defrost thermostat and wire nut the new one in.Very easy fix as the part just clips on radiator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Indianapolis, IN
- Parts Used:
- WP2187464
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
no power to the ice maker
The wiring harness was a straightfoward plug in replacement after depressing the securing tabs, and did provide power to the icemaker. However, the icemaker would continually cycle, with the mold heater on at all times. I suspect this is what caused the thermal fuse to blow in the first place. Rather than spend more time replacing individual components, I eneded up replacing the full ice maker assy. The new ice maker works properly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- NANCY from VALLEY VIEW, OH
- Parts Used:
- W10190935
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Water dispensed, but no ice.
We have a side-by-side and the tutorial was different than what we have. Had trouble getting cover off, but finally repaired and WE HAVE ICE! Also took longer than expected.
Saved a lot!
Saved a lot!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOSEPH from LINDENHURST, NY
- Parts Used:
- W10190935
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Icemaker Quit Making Ice
Removed the two screws that hold flaping door. Removed the single screw that covers the connecting wires. Disconnected the wiring plug. I wiggled out the ice maker. Took off the motor cover. Swapped out one motor for the other. Reinstalled the icemaker in the resverse order of removal. Note the wiring plug in the freeze is very from. It makine s the reconnection differcult.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Antonio from San Antonio, TX
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Monica from EDMOND, OK
- Parts Used:
- W10823511
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Matthew from Iselin, NJ
- Parts Used:
- WP2201801
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Wrench set
The tray evaporator developed a leak due to rust.
Using the parts list that came with the refrigerator, I ordered the exact replacement part. First I removed the single nut that holds the tray onto the top of the compressor with a standard wrench. Then I carefully removed the pan filled with condensate taking care not to damage the coils. I then inspected the area and wiped off the dirt. I inserted the new evaporator tray carefully into position. The tricky part was starting the nut that secures the pan because of the confined space that I had to work in. Long fingers worked the best. After 3 attempts I was able to start the nut, and then I finished it off by tightening with the wrench. It is best to keep the parts list that comes with your appliances.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Duncan from Metairie, LA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Arlington, TX
- Parts Used:
- 4387478
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Roanoke, VA
- Parts Used:
- 4387478
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Center Moriches, NY
- Parts Used:
- WP2315576
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Icemaker just stopped making ice one night
I pulled the refrigerator out from the wali slowly so not to damage the water line to the ice maker. Then with a nut driver I removed all the screws holding the back plate on. Being careful not to kink the water line, I used the adjustable wrench to losen the water line feed nut and the nut that goes to the line to the icemaker. Then I removed the screws holding the valve in place finished unhooking the water lines with my fingers. I then got the new valve and finger tightend the main water supply nut to the inlet side, then I pushed the plastic supply tube going to the icemaker into the valve. The new valve does not use a nut to attach the tubing it is a presure fit very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sam from Las Vegas, NV
- Parts Used:
- WP628356
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Water Fill Cup Broke
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Annapolis, MD
- Parts Used:
- W10190935
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
The icemaker in my freezer stopped producing ice
1. Removed the icemaker door
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
Was this instruction helpful to you?
Thank you for voting!