- Customer:
- Jo Anne from Easley, SC
- Parts Used:
- 625851
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
took out old switch, replaced with new one from parts select.
Took out icemaker,it had been letting in too much water, foynd switch was not working anymore, ordered new one from PartSelect, got it in a few days,took icemaker out put new switch in & it is working like new. I was amazed I could still get parts for a 28 year old whirlpool. And with the help I got from PartSelect,I am really thankful. JoAnne, Easley, S.C.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Orange Park, FL
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Ice Maker quit workin
Turned off water supply and electricity. Removed old valve by removing two 1/4 in nut screws and water supply line and the ice maker suppy line. Disconnected the electrical line.Reattached water supply line,the icemaker supply line and the electrical connector. Put valve back into refrigerator and attached the two 1/4 in nut screw. Turned on water supply and electricity. Bled water thru system and now have plenty of ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Little Falls, NY
- Parts Used:
- W10822278
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Noisy defrost timer
Part # had been replaced with another timer. Original timer had 2 wires coming out of it. Replacement only had 1 wire. Instructions showed 2 options for where to place the wire. I chose option 2 and I guess I was right. Installation took less than 15 minutes and refridge is back to normal. (Quiet)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patrick from Sun City, AZ
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The refridgeror side was not cold enough
it was a simple repair once I located the part I had to replace . I really like your speedy delivery of the part I needed Thank you Pat Crotty
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judith from Phoenix, AZ
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Bulb Replacement
I pulled down the wire around the glass cover. . . Released on end of the wire from its holder being careful to not let the glass cover drop. Unscrewed the bulb and replaced with replacement. Easy, easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Morgan, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noisey fan
yup
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from LAS CRUCES, NM
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from New Albany, IN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from Torrance, CA
- Parts Used:
- 482469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Intermitant squealing noise from freezer area.
I basically followed the step-by-step instructions at the parts order website. I removed the shelves and rear panels to access the fan. I noted the color coding on the wires and terminals, removed the two retainer screws, removed the old fan from the mounting bracket, installed the new fan using the rubber anti-vibration mounts, pressed-on the fan to the center drive shaft and re-installed the assembly to the back wall. I simply replaced the rear panels and shelves and plugged in the fridge. The only issue I had was the distance needed to press on the fan blade to preclude fan noise, which I found by trial and error, before re-installing the panels.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOHN from TWINSBURG, OH
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Water Was Not Reaching The I Ce Maker
Disconnect ac power line, disconnect power line going to the water valve. Turn water off atthe cockvalve. Disconnect water line to valve. Disconnect plastic tubing going in the valve. If plastic is old you may have to replace it to keep from leaking at the quick connect coupling. Connect water line and plastic tubling to new valve, connect power clips to new valve. Plug in the refrigertor and turn on water at the cock valve and your good to go
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from woodstock, MD
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
excessive water in condensate pan
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Brooklyn, NY
- Parts Used:
- 4387478
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Protective cover for bulb had melted
I tried to just replace the cover rather than the whole unit but it was impossible - the cover would not go/stay on. I tried to remove the old unit completely but it would not unplug it was practically fused to the back of the fridge and the liner was cracking. I ended up breaking the cover and jerry rigging it over the bulb to prevent items in the fridge from being able to touch. Bad solution.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denise from Manchester, NH
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Ice Maker was overflowing into ice bin when filling
Thought we'd try the Water Valve before replacing the ice maker. Ordered new valve online on Saturday, it arrived on Tuesday. I installed it twice in less than 30 mins. Had a little leak the 1st time, so I uninstalled it, trimmed up the water line with a box cutter and reinstalled without issue. No leak this time. Easy Peasy. My husband said "You're good, you." :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Kent, WA
- Parts Used:
- 482469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
high pitch intermittent screech sound coming from within the freezer compartment.
Unplugged freezer, removed lower shelving, removed panel covering the evaporator motor. Unpluged three wires connected to fan assem and removed. Did not install new wiring that came with kit but installed new motor/fan and reconnected existing wiring. Problem gone!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Burton from Mount ShaSTA, CA
- Parts Used:
- W10822278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
frosted evaperator
I was a Sears repair man for fourty eight years , so I don"t think I should say how easy this was.
Was this instruction helpful to you?
Thank you for voting!