Customer:
charles from REDDING, CA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Warm refrigerater
Followed instructions from ideoo
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cecelia from Garden City, TX
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer made lots of Ice and Refrigerator didn't cool
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator brand new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.
4 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from Mesa, AZ
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GREGG from WEST CHESTER, PA
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker was not working.
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice maker. Gregg in PA.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Lowell, MI
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
alfonso from Fairfield, CA
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator compartment warm
first confirm that freezer is cold. if is frozen solid it needs to be defrosted. take the freezer items out,take shelf out, bottom cover, 2 screws. then ice maker, 3 screws and unplug wires. then back panel 2 screws. In refrigerator compartment were the controllers are located, look under it you will see 1 hole, insert a flat end screw driver and turn clockwise till it stops. this action will turn on your defroster, also the compressor will stop. is the heater melting the ice? if so soak up water and clean tray, use hair dryer in drain hole to aid in the defrost, check tray under fridge and if its dry keep defrosting. it should take half an hour. now take the flat head screw driver and turn the defrost timer clock wise out of defrost mode a quarter turn or so. the compressor should come back on, soon after the fan in the freezer compartment should also come on. this steps lets you no that the defrost heater works, fan works and drain hole is clear. if its defrosted place parts back in the reverse order. if not defrosted replace heater or mother board. in refrigerator compartment were the dials are located their are 2 screws, one on the left and the other on the right side take them out, the cover will drop down, you will find wiring schematics you will need them to install defrost timer. is timer making ticking sound? if no replace timer. new timer will be different from original so follow instructions that come with it. timer is above were the hole is located. the plastic hold downs will break when you try to take them off, unplug fridge, lift timer out and remove from wire harness. the new timer has a black wire that slips over either 1 or 2 depending on color of wire on the wire harness. check schematics. some silicone adhesive will keep unit in place, ad some into the plastic shaft prior to installation, plug wire harness return wiring instruction along with new one inside of cover, plug in fridge, turn defrost timer clock wise with flat head screw driver making sure that you hold timer from above so it wont move. did compressor come on?. put all paper work inside of cover before installing cover
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Al from Tonka Bay, MN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Condenser Fan Failure
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Milford, MA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
freezer and food section too warm
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Lewisburg, WV
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Solenoid stem had seperated from valve seat.
Turn off water, removed two mounting screws, unplugged solenoid, removed incoming water connection and plastic pipe to ice maker. Installed new valve, connected water lines, reconnected plug, remounted with screws. Turned water back on, over rode power to ice maker and checked for leaks. Total time about 5 minutes. Very easy repair.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
william from whitwell, TN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set, Wrench set
fan motor had gone bad
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Belhaven, NC
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ROBERT from KIRKWOOD, MO
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
The freezer worked but the refrigerator wouldn't cool.
When we got the part, we read the instructions, which were easy and very clear step by step. Taking the old part off took most of the time, it was attached a little differently than was described in the video and the instructions for the part. Once we detached that, the replacement part went in very easily and quickly. It took a short while for the cycle to start, we were actually a little worried that it wasn't going to work. Then it started cycling. After the first day the freezer had started icing up, we took a blow dryer and melted it and waited. It hasn't started freezing up again. The refrigerator is keeping the proper temperature and the freezer is also working properly, it's been a week. We seem to be obsessed with going out and checking to see if it's working but I think it's a success. Doing this ourselves only cost $26.00. A huge savings if we had hired someone else to repair it for us. We will definitely choose this option with any other appliance that needs repair. It was easy and simple to find the correct part thanks to the website. And the video tutorial was very informative and helpful.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from COVINGTON, LA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Curtis from Sedona, AZ
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Atlanta, GA
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
The Ice was hollow and then it just t stopped.
The first issue was to determine if the problem was with the ice maker or the water dispenser / pump. I chose to try to repair the dispenser first since there air bubbles in the plastic line. Also, the ice maker seems to have been working. There just wasn't enough water so the ice cubes were hollow.

I unplugged the power cord, , removed the cardboard backing and two bolts that secured the pump to the refrigerator. I vacumned the area so I could see around. I pulled the valve out and disconnected it from the internal power source. I disconnected the copper water intake and the plastic tubbing to the ice maker. I used a pipe cutter to take the old flanged area off. A new flange was included in the package. I used that and reconnected the copper intake and the plastic tubbing. I replaced the power source and secured the valve to the refrigerator makeing sure the plastic tubbing wasn't twisted. When I plugged the refrigator back up, the ice maker started working within five minutes.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?