59669313011 Kenmore Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- William from FAIRFIELD, VA
- Parts Used:
- WPW10503278
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Unit would not defrost
I checked the element and the thermostat and determined the problem to be the control board. I simply followed the instruction in the video. Everything went well until the last step, the video said to push the freezer down button. When this did not work I refered to the written instructions which told me to push the up button. That did it. Job complete. The unit is working as it should.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Meridian, ID
- Parts Used:
- WPW10503278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Lower freezer section was icing up, not defrosting properly. Repeated manual defrosting including disassembling did not solve the problem.
Emptied and disassembled the freezer. Defrosted and dried the coils. Tested the defrost heater coil ( 50 ohms ) PRT and fan - all OK. Opened the lower back panel and cleaned the water collection tray. Vacuumed out all debris including coils underneath. Reassembled everything. Removed the old control board and installed the new board paying attention to ESD steps. Applied AC power. Programmed the new board per the video link ( nicely done ). 3 weeks later and the unit seems dry and happy. Running at lower settings with good temperature results. Suspect the 24VDC relay activating the defrost heater coil on the control board or what controls the relay not working. May pull relay for test.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from JACKSON, MS
- Parts Used:
- WPW10503278
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The control indicators would flash and buzzing noise came from the controler
Followed the video exactly as shown from the website. I do suggest using a mirror or your phone to visualize the notch to press to drop the cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from DEARBORN, MI
- Parts Used:
- WP67003637
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Our old plastic dairy door had a broken part and it kept coming undone
The new door just popped into place. Took seconds to complete. Fast delivery too.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel F from CALEDONIA, MN
- Parts Used:
- W11613295
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer and refridgerator just stopped working.
The Condenser Fan Motor was already removed due to searching for the problem. The new fan motor looked different from the original but I felt very comfortable that Part Select had sent me the new part showing original part number changing numbers over the years. Simply placed the fan blades onto the new motor lined up 2 of the holes placed screws and tightened then plugged the wire ribbon into the Condensor Fan Motor, plugged in the Refridgerator and it worked beautifully.
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from AUBURN, CA
- Parts Used:
- W11396033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refer lights not working, there are two lights and neither worked. Decided the switch was the problem.
The switch fix but did not fix the problem. I assumed the wires go on the same way as on the old switch. Is it possible if one light Burns out, the other will not work either?
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jacob from SHEBOYGAN, WI
- Parts Used:
- WP67006877
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Old glass broke , new glass fit perfect
Just set the glass shelf onto frame perfect fit
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carlton from CHICAGO, IL
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light out.
Popped out the old switch and replaced it with the one dying
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Neil from WILMINGTON, MA
- Parts Used:
- WPW10671238
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broken center crisper rail
Lift off glass shelf and insert tabs of rail on each end , replace shelf.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carolee from Spokane Valley, WA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light switch broke
Pried out old part with screwdriver. Unplugged. When new part came, just plugged it in and pushed the part into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from McKinney, TX
- Parts Used:
- W10619951
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Water pooling on the floor.
This problem is caused by a "Duckbill" rubber grommet attached to the bottom drain tube of the freezer. This duckbill opens up during the defrost cycle and allows water to drain down the "water slide" to the evaporator pan. It doesn't take much to gum the Duckbill. Once gummed up the defrost water is trapped. The Defrost Cycle eventually makes the water flow out of the coil area to the bottom of the freezer then eventually to the floor. The repair involves unplugging the unit, removing the bottom back cover with a 1/4 nut driver, pop the power clip out to give you room, reach in and pull the duckbill grommet and the water slide, then installing this replacement drain kit. This is a p trap replacement that actually fixes the root cause of this problem. A tricky part is removing the water slide, you can see the white snap that holds the slide in place. Using a small flat blade from the top releases the snap and the unit is pulled upward rather easily. This replacement drain clip snaps in the same place. If I had to do this again it wouldn't take more than two minutes to replace. Oh, one major thing, you need to manually defrost the unit. I pulled the front door off, it is held with 4 screws ... don't remove them just loosen them and it pops off easily. I pulled the bottom tray out an it gave me room to squirt hot water with a baster into the back freezer area. Eventually everything thawed out. If I had it to do over I would have waited on connecting the tube to the evaporator pan and placed the bottom of the tube into a small sauce pan or something to collect the drain water and easily dump it into the sink. I used a sponge and that took forever. BTW, just to reiterate, use this item and not that Duck Bill for replacement, this actually fixes the root cause of this problem!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Arthur from WYNNEWOOD, PA
- Parts Used:
- WPW10671238
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Rail snapped
Followed video
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from PORT JERVIS, NY
- Parts Used:
- W11396033
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
No problems
Just plugged it in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PHOENIX, AZ
- Parts Used:
- W11613295
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The refrigerator was working for just 1 minute and breaks, I discovered that the fan was not working , I understood that there wsa something wrong with the condenser fan motor. I just order a new one.
The installation video for condenser fan motor helped a lot to know how to disconnect the old fan motor and connect the new one. So easy just know how to remove and put back the fan gently, observe carefully where is the center and the connector position; 15 min after everything was done and the unit works well to date.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nancy from LOUDON, TN
- Parts Used:
- WP67006877
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
broken glass shelf
Replaced shelf, very simple
Was this instruction helpful to you?
Thank you for voting!