Customer:
Amy from PITTSBURGH, PA
Parts Used:
5304464438
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer and refrigerator stopped cooling
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard Allen from PHOENIX, AZ
Parts Used:
241798231
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Replacing Icemaker
Pull refrigerator from wall and disconnect the water line and unplug the power.

On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.

Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..

Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.

Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.

In about an hour you should have ice filling the bin. Enjoy!
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Las Vegas, NV
Parts Used:
242252603
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker stopped working
Took off old part and installed new part
11 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from SAVANNAH, GA
Parts Used:
241537103
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Not running
After waiting over 2wks for my part to arrive, I purchased the part locally and made the repair the same day as I am still waiting for the part to arrive from you guys. Your customer service really needs improving. I paid for 2 day shipping, what a joke. I will be returning the part as soon as I receive it thanks.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from Middletown, DE
Parts Used:
5303918277
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
ice maker quit making ice
I basically followed the instructions offered when i searched for the ice maker. It was relatively easy to do, I undid the 2 screws holding the ice maker to the side of the freezer, the was the tricky part, holding a mirror so i could see the slots of the screws. loosened them, disconnected the electrical connection and reversed the process for the install. It took about 25 minutes and i was back making ice.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karine Lepold /BM CARGO from Miami, FL
Parts Used:
241872501
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Freezer door gasket with a holes
/
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lise from CEDAR GROVE, NJ
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Oven light bulb went dark; it needed replacing
Twisted replacement bulb into place easily. Let there be light!
10 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from parker, CO
Parts Used:
5303918549
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharon from Cannon Beach, OR
Parts Used:
240383801
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
A shelf in the refrigerator was broken off by a renter.
It was very simple - just had to pop the part in. Delivery was quick - very slick!
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Front Royal, VA
Parts Used:
240505801
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Switch would not allow door to close.
Removed screws holding unit and removed unit. Removed switch from connectors in unit. Replaced unit without switch. On day switch arrived (delivery was prompt) my wife replaced switch by attaching the two connectors and slipping into unit without having to remove entire unit. How easy was that!!!
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Azle, TX
Parts Used:
5303918277
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Original Ice Maker quit working.
Loosened the 2 screws a little so that it would slide up and off then unplugged the wire harness.
Installed the new one in reverse order and works like a champ.
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from McBee, SC
Parts Used:
5303918774
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
harry from terre haute, IN
Parts Used:
5303918277
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
my old ice maker leaked at the bottom
it was really easy changing the ice maker. the only trouble i had was the wiring. it was very stiff and hard to route. it did not work at first but that was my fault did not have the connector plugged in all the way.since then it works great.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Denver from BLAIRSVILLE, GA
Parts Used:
5303918549
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ANGELA from MEBANE, NC
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!