Customer:
Martin from Shakopee, MN
Parts Used:
WPW10190929
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice stuck in mold. mold coating was peeling off.
Turn off water supply too ice maker and unplug the fridge power. using a nut driver remove one bottom screw from the bottom, near the front. The other two from the side atop the ice mold. (loosen screws and ice maker will lift up and off.)
I set the ice maker on the counter, snapped of the front cover by hand. using a phillips driver, remove two screws near the bottom corners.(they go through the circuit board into the ice mold)
circuit board in one hand, other end of ice mold in the other, slowly pull apart about 1 inch. remove the silver colored "on, off" bar at the end by snapping the retainer out of the ice mold. (the silver bar stays with the circuit board end)
Watch how the ice guide(white fingers stationary on side of ice mold) hooks too the ice mold on each end. swap ice guide to new ice mold, insert three guide pins on end into holes on the circuit board, while holding ice guide onto ice mold, watch rotation bar while inserting into motor.(it only splines one way.) when each piece is lined up, simply push together and reinstall two screws. snap circuit board cover into place. reinstall ice maker into freezer in reverse order.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Albert from Centereach, NY
Parts Used:
4317943
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Wasn't making ice
Took off door to ice maker. Unscrewed 1 nut. Slid out unit. Unplugged electrical connector. Unsrewed 3 nuts from bottom of old unit & attached mounting bracket to new unit. Reconnected electric connector. Slid back in. Put screw back in. Put icemaker door back on. Turned icemaker on. Ice in 20 minutes!
13 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
sandra from mechanicsville, VA
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
ice dispenser broken
ridiculous how a tiny plastic broken part required a full motor assembly replacement. that being said, i went online, found this website and easily identified the part i needed to order. i was impressed when it arrived within a couple of days. removing the old motor and replacing the new was a piece of cake...and i am NOT mechanically inclined,
17 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matthew from Aurora, CO
Parts Used:
WP628356
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Broken cup water fill on ice maker
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.

Thanks,
Matt
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven S. from Kerrville, TX
Parts Used:
WP2315576
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Leaking water inlet valve
This would have been a less-than-5-minute repair except for one item. The water intake nossle was 180 degrees from the original part. As a result, the copper water inlet tube would not fit in the old space and still allow me to reattach the valve to the freezer chassie. I ended up leaving the valve hanging loose under the freezer. I spent most of my time trying to fit the valve into the old space.

Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.

Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished

Everything works just fine !
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lawrence from New Bern, NC
Parts Used:
WP4387503
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Freezer compartment iced over, food thawing,
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back portion to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from miami, FL
Parts Used:
WP4387503
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
water was leaking down from freezer section to bottom part of unit
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me access to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matthew from Miller Place, NY
Parts Used:
WP2304099
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
no auto defrost
Quoted $275 to fix, paid $65 for the part , Installed the new part in about 15 min. very easy, removed 2 small screws, and plugged in new part.
15 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ron from Ferndale, WA
Parts Used:
4317943
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
No water to the ice maker
At age 65 I have never attempted to repair a refrigerator, until now. It took longer than needed because I did not read these articles carefully. Please note that when you open the door and the light blinks twice, waits a second and blinks again, the optics are working fine. I ordered an emitter and receiver when I didn't need to. I sent it back, the money was refunded, and ordered the ice maker. I replaced the old icemaker by removing three screws and slipping it out of its holder.

Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Spring Valley, MN
Parts Used:
W11510803
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers, Wrench set
installed ice maker
From the time I started to finish I worked 3 hours, this included installing the new ice maker, cutting into the cold water line in the basement and installing a t with a 6inch piece of pipe with a compression valve to connect to the small cooper tube, this is worth your time to do it this way, its a lot better connection than the small pierce valves that come with the kit, they will leak over time. I installed the filter in the waterline in the basement for easy access
13 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
martin l. from JACKSONVILLE,, IL
Parts Used:
4387478
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
socket melted with bulb in it.
plastic warped in ,spaced out and, the socket snapped back in place.
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lori from Chuluota, FL
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joyce from Kerrville, TX
Parts Used:
WP2195916K
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Didn't know if I needed Left or Right.
The item is listed as R, meaning right hand side. If you need it for the left hand side, simple turn it over. It is designed to work on both sides of the door.
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from West Chicago, IL
Parts Used:
WP2163835
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken shelf support
snapped in. The best part was the ease that i identified the part due to your website.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Medway, MA
Parts Used:
W10190935
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker motor would run continuously but the blades would not turn and no ice came out.
I wasn't sure what the problem was, but the ice maker seemed simple and on-line resources suggested the control and motor assemblty was at fault. I searched the internet and Partsource had great diagrams which I could match to the part in hand. The price was right (way less than the local stores) so I ordered it.
I unplugged the unit from the power in the freezer, but unplugging the entire refrigerator works too. I pried off the white cover on the front of the ice maker, which snaps in place top and bottom. There are three screws holding the contoller (the entire front piece), remove them, pull off the controller and push the new one in place. You may have to turn the blade shaft to line up the notch on the shaft to the motor. Then reinstall the three screws, The screws go into plastic so it is easy to cross thread them, so be careful, I actually think I did with no ill effects. Snap on the cover and repower the unit. Done. Simple and quick.
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!