Chrisper pan support cracked due to overfilling
removed old shelf support after taking out the glass and support. New part was a perfect fit that was a "shap: to put in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from East Meadow, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
light not working in fridge
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clive from parlin, NJ
- Parts Used:
- 2159073
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
old gasket was not sealing door would open when freezer door closed
remove door pull gasket out put new gasket in replace door
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from North Palm Beach, FL
- Parts Used:
- W10822259
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Motor Bearings Locking Up
Removed the back panel on the refrigerator--unplugged the condenser fan motor--removed the motor--placed a small fan to cool the condenser--called parts select--ordered the motor--the motor arrived less than 24 hours after I ordered it--replaced the motor and rear panel on the refrigerator--probably saved more than $200. 00--Very happy with parts select service--plus I had a misunderstanding with my credit card and john at parts select was very helpful --not their fault--excellent company
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STEPHEN from FENTON, MO
- Parts Used:
- WPW10225581, W10822278
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer No Longer Cools
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Troy from Kansas, OK
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezer wouldn't defrost/low temps in refrigerator
Found the housing for the thermostat; took housing apart pulled out thermostat and took off the hose put the hose on the new thermostat installed new thermostat and replaced housing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- roberto from san Antonio, TX
- Parts Used:
- WP2198202
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
freezer gets too cold then gets to regular tempetured
disconect the power removed the screws with the phillips screwdriver removed the front cover and then removed the rest of the screws. removed the three covers and then removed the thermostat. replaced in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ryan from Hudson, NC
- Parts Used:
- 8201799
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
freezer and fridge would not get cold
Take off back lower fridge cover. Removed old startup device. Installed new 2 piece device. Done
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from NAYLOR, MO
- Parts Used:
- WP2188664
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Crack in vegetable drawer
Emptied draw of contents pulled draw out and inserted new drawer....easy pea-zee
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from North Port, FL
- Parts Used:
- WP2188664
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
broken drawer
replaced
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Antonio from San Antonio, TX
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Lewisville, TX
- Parts Used:
- WPW10329686
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Socket set
Refrig Door Cams wore out and made noises when opening and closing.
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two year old Frig. This is a design problem, as the cams should last longer than 22 months.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyle from Wimauma, FL
- Parts Used:
- WPW10329686, WP488729, 8201707
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Black Cam was bren on lower door hinge
This was a very simple job. Remove the top Hinge bracket, a total of 4 screws, lifted the door off the bottom hinge, removed the bottom hinge set up, 2 screws, replaced it, and attached the new bottom black door cam, lifted the door back onto the bottom hinge and aligned the top hinge, and reinserted the screws, and Ta Da, The door works like a new refrigerator door. 15 to 30 min tops. I did not even have to take the refrigerator items out of there door holder.
Was this instruction helpful to you?
Thank you for voting!
Fan motor was making noise.
First I removed all food in freezer.Then removed selves and hanger brackets.Then the back panel and light cover.Then I unplugged motor but before this I unplugged refrigerator from the wall.Removed motor from bracket after pulling of fan. Reversed the order to install motor and put back together
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jairaj from North grafton, MA
- Parts Used:
- WP2182179, WPW10329686
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The refrigerator door was hanging low and not closing properly. Hence the refrigerator was not maintaining the temperature
First removed the three screws at the top that holds the door at the top. Removed the worn out lower door cam after removing one screw. Did the same on the door closing cam (in fact this cam has worn and broken into two pieces). Replaced with the new ones, put the screws back, mounted the door and replaced the three screws on top. The door closed perfectly.
Since this did not help with keeping the refrigerator cold, a day later I had to vacuum the dust off the coils (on the underside of the refrigerator) and thaw the ice from the freezer compartment clearing the ducts to re-initiate the proper flow of air between the two compartments (I learnt on the internet that cold air from the freezer is drawn to maintain the temperature in the refrigerator compartment). The faulty refrigerator door ended up icing our frost free referigerator's freezer compartment and the air ducts in it. Therefore I had to simply turn off the refrigerator for 12 hours, thaw everything and restart! I know nothing about refrigerators. Just did it after visiting your site and a couple of other sites. Saved me about $300!!
Since this did not help with keeping the refrigerator cold, a day later I had to vacuum the dust off the coils (on the underside of the refrigerator) and thaw the ice from the freezer compartment clearing the ducts to re-initiate the proper flow of air between the two compartments (I learnt on the internet that cold air from the freezer is drawn to maintain the temperature in the refrigerator compartment). The faulty refrigerator door ended up icing our frost free referigerator's freezer compartment and the air ducts in it. Therefore I had to simply turn off the refrigerator for 12 hours, thaw everything and restart! I know nothing about refrigerators. Just did it after visiting your site and a couple of other sites. Saved me about $300!!
Was this instruction helpful to you?
Thank you for voting!