JCD2289AEK Jenn-Air Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Dwayne from Gastonia, NC
- Parts Used:
- WP61004888
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
evaporator fan was noisy
First I unplugged the refrigerator. Next item was the ice-maker; remove (3) screws and unplug it from the back wall. Third task is remove the (4) screws that attach the back wall of the freezer compartment. Lift the wall up enough to dislodge the center cooling shaft that the fan rides in and remove the rear wall. The last item is the fan motor which is attached to the freezer wall by (2) screws and (3) wires which are easily removed. Change out the motor and reassemble freezer compartment .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Albert from Culver City, CA
- Parts Used:
- 61005988
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Compressor running continually, and refrigerator too cold
Maytag wide by side refrigerators tend to eat these parts about once a year, and this is my third assy so the replacement went very fast. When we used the Maytag warranty they replaced this part about 6 times, after they exchanged the refrigerator. No major disassembly is required, drop the plastic after removing a few screws, plug in the assy, and you are good to go, no more frozen food in the refer. The only tricky part is getting the clips to release so you can slide the plastic cover forward, but after a while they break off and it is easier to remove.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Johnson City, NY
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Valencia, PA
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Ice maker just stopped making ice
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Denver, NC
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rosa from Whittier, CA
- Parts Used:
- 61003971
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken Dairy Door On Refridg.
Removed broken dairy door (no screws or any tools were used) and replaced with new one purchased from partselect. It took me less than a minute to do :) thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Orlando from Bayonne, NJ
- Parts Used:
- WP2300868
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Old one leaks on one side
Simply cut the water tube on both sides of connector and push in the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Hilton Head Island, SC
- Parts Used:
- WP61005944
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Refrigerator door seal leaking and the beer was not getting cold.
Removed the inner door panel held on by 30 small nuts crews. Removed the old seal. Stretched new door seal onto inner door panel. Attached inner door panel and seal to inside of refrigerator door. Using a magnetic nut driver was the answer in the tight spots and the small nut screws. Everything works fine and the beer is cold again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CHARLENE from BONITA, CA
- Parts Used:
- 61004718
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Chill compartment section craked and chill door was falling off.
First off, We have an extended warranty however, they said it was not coverered since it did not affect the function of the refrigerator (except that we lost refrigerator space and could no longer use that section of the fridge!!!) They said it was cosmetic!! After having a repair person come out and tell for the part and repair it would be $217.00.
I then got on line and looked up the part which with shipping cost us 37.00. My husband installed the part in no time.
Word of advice: make sure when you purchase warranties that you check the fine print ,because there are all different levels of warranty.
I then got on line and looked up the part which with shipping cost us 37.00. My husband installed the part in no time.
Word of advice: make sure when you purchase warranties that you check the fine print ,because there are all different levels of warranty.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from north berwick, ME
- Parts Used:
- WP61006199
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
cool was freezing up causing ther fridge to get warm
1.Pulled all ther baskets and shelves out of freezer and unplugged unit.
2. Using a nut driver remove screws holding coil covers in place on the back wall.
3.Use a hair dryer to fully defrost the coil in the freezer allowing you to unplug the electrical connector and take the thermastat control switch off the cooling tube.
4. Pull out aluminum pin between coils holding heater coil in place on right side.
5. Remove black foam insert on right side to allow removal of coil wires
6. reverese to reinstall
* Note this heater replacemnet coil did not fix my problem. I consulted a Maytag Repairman who told me to relace it..well he was wrong so I further researched the problem and found my problem was the ADCB inside the refrigarator. I strongly suggest you replace this part first and wait 8-12 hours and recheck the condensor coil. Some frosting will occur but tha ADC ( automatic defrost control board will cause the defrost heater to come on at all diffrent times according to your usage of the appliance. total cost was under 100.00 to replace the heater coil and ADCB. A bargin compared to the $400-$500 the Maytag guy would charge to do the same.
2. Using a nut driver remove screws holding coil covers in place on the back wall.
3.Use a hair dryer to fully defrost the coil in the freezer allowing you to unplug the electrical connector and take the thermastat control switch off the cooling tube.
4. Pull out aluminum pin between coils holding heater coil in place on right side.
5. Remove black foam insert on right side to allow removal of coil wires
6. reverese to reinstall
* Note this heater replacemnet coil did not fix my problem. I consulted a Maytag Repairman who told me to relace it..well he was wrong so I further researched the problem and found my problem was the ADCB inside the refrigarator. I strongly suggest you replace this part first and wait 8-12 hours and recheck the condensor coil. Some frosting will occur but tha ADC ( automatic defrost control board will cause the defrost heater to come on at all diffrent times according to your usage of the appliance. total cost was under 100.00 to replace the heater coil and ADCB. A bargin compared to the $400-$500 the Maytag guy would charge to do the same.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from Newton, NJ
- Parts Used:
- 61003803
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
The solenoid from that operates the fountain went south
I ordered new solenoid that came with door. I installed it and it was making a very loud buzzing noise. I also had a frost buildup between the icemaker and the icemaker chute in the door. I posted my problem on the forum and Sheila suggested that the heat from the defective solenoid might have distorted the fountain housing, causing the new solenoid not to seat right, and possibly letting outside air into the icemaker. On closer inspection I saw that the hosing WAS distorted. I ordered a new one, installed it, problem solved! Hats off to the staff here, where else can you get a diagnosis first -so you know what parts to order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kelly from Brentwood, NY
- Parts Used:
- WP61006199
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
the fridge side work fine, the freezer won't freeze
I used a nutdriver to unscrew the four bold, I disconnect the defrost heater assembly, I used boil water to unfreeze where the heater assembly hook, then I unclip the bottom I remove it and slide the new one the same way and replaace those two covers and connect the fridge back and it work like a charm. Thanks again Partselect. I save a bundle money and waiting time....
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Montague, NJ
- Parts Used:
- WP61006199
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Defrost heater not working
I removed the cover and unplugged the heater unit and thermostat. I then checked the resistance of the unit. The unit was bad. I then replaced the unit.
This was a very simple repair.
This was a very simple repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Rushville, IL
- Parts Used:
- 61005626
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
the water dispenser was leaking
I took off the backing off the back of the refrig. & the water valve with a nutdriver. Then unpluged two wire connectors & disconnect three water lines. Pulled out the old valve & hooked-up the new valve in reverse order. It don't get any easer than that. The dripping water dispencer was no more.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from colonia, NJ
- Parts Used:
- 12001991
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
automatic ice door would not open
removed the front panel on freezer door ,removed and disconnected panel ,removed panel containing solenoid,replaced with new solenoid. replaced all parts. works perfect..
Was this instruction helpful to you?
Thank you for voting!