JSD2588AEA Jenn-Air Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Richard from Williamsburg, VA
- Parts Used:
- EDR7D1
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
replace water filter
Unscrewed old filter and screwed in new filter.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from Flowery Branch, GA
- Parts Used:
- WP61005253
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Icemaker was giving crushed ice only
First I rolled the fridge out and unplugged the power cord. I then removed the ice bin. There was one screw to the left under the ice bin rack holding it in. After removing that screw, I could pull the rack out far enough to disconnect the electrical connector. You have to squeeze the wings b-4 you can pull the connector loose. I put the rack on the countertop, removed two screws and the solenoid with plunger came out. I replaced the old solenoid, put everything back together, and realized I probably just saved myself $300. My Wife thinks I'm a Hero again. It works fine now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Phyllis from University Place, WA
- Parts Used:
- EDR7D1
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Needed to replace filter
1/4 turn of old filter. it popped out. Inserted new filter, 1/4 turn and it clicked in. Piece of cake. I'm a freakin' genius.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from Milford, OH
- Parts Used:
- W11342242
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker was over producing
Technician at ASK suggested replacing ice maker. Ordered new ice maker(prompt delevery)then noticed it came without wire arm and white platic "flag". Ordered arm and "flag", replaced all old with new and seems to be doing well. Perhaps all I needed was the plastic "flag" on the limit arm wire. Will never know. The new icemaker wiring had short wires and a connector. Old ice maker had no connector so the short wires were removed and the old wires plugged into the ice maker. Mirror was required in order to see the side wall mounting screws. Very narrow work area, tiny freezer side.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gary from carleton, MI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
My icemaker started leaking water into the catch basin and turning my ice into one big ice burg.
Well folks I put up with an ice burg all summer when I really should have took the time to fix it. You know how it goes though. You get so busy you just put it off.
Well don't put this one off because this is just how easy it went.
I came home one evening and wanted to make a drink to relax but that big glob of ice was there waiting for me. I took a crewdriver and beat it down so I could pull the catch basin out. Having looked it over for a minute I grabed a nut driver and took three of the screws out that held it in. I unpluged the wire and bingo it was out. Maybe five min. had elasped.
After taking the unit out I notice how the non stick surface was coming off of the tray and that explains the black pieces that were getting into my ice.
Getting the model number off the back of the fridge and writing it down I went to my trusty lap top and did a quick search for a ice maker for my Jenn Air refrigeraton and blamo...! Part Select came up and I put the part number in their search engine and bingo again there it was, my part.
One quick order and in three days it was right there by my door when I got home.
Now i'm so excited. I went into the house and didn't even chage out of my dress clothes. Within five minutes it was in. Now I just had to wait for the timer to do it's thing and sure enough, I awoke the next morning to a whole tray of beautiful ice cubes. Wow no more ice burgs.
The moral of my story is I spent so much time hacking out that glob of ice and for fifteen minutes of my time, I could have been siping on cold ones by the pool but now old man winter is pressing down on me and I guess a lesson learned was a lesson earned. Fix it!
Well don't put this one off because this is just how easy it went.
I came home one evening and wanted to make a drink to relax but that big glob of ice was there waiting for me. I took a crewdriver and beat it down so I could pull the catch basin out. Having looked it over for a minute I grabed a nut driver and took three of the screws out that held it in. I unpluged the wire and bingo it was out. Maybe five min. had elasped.
After taking the unit out I notice how the non stick surface was coming off of the tray and that explains the black pieces that were getting into my ice.
Getting the model number off the back of the fridge and writing it down I went to my trusty lap top and did a quick search for a ice maker for my Jenn Air refrigeraton and blamo...! Part Select came up and I put the part number in their search engine and bingo again there it was, my part.
One quick order and in three days it was right there by my door when I got home.
Now i'm so excited. I went into the house and didn't even chage out of my dress clothes. Within five minutes it was in. Now I just had to wait for the timer to do it's thing and sure enough, I awoke the next morning to a whole tray of beautiful ice cubes. Wow no more ice burgs.
The moral of my story is I spent so much time hacking out that glob of ice and for fifteen minutes of my time, I could have been siping on cold ones by the pool but now old man winter is pressing down on me and I guess a lesson learned was a lesson earned. Fix it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jon from Boise, ID
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
No ice
1 screw remove assembly. Unplug cable harness and remove old cover and wire arm. Replace cover and wire arm and attach wire harness on assembly end. Re attach using screw removed in first step. Plug in wire harness. Making ice within 30 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Columbus, OH
- Parts Used:
- 61005614
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Replace ice enclosure
The plastic around the the drive motor on the ice enclosure fatigued and broke. Couple if screws and the whole thing came. Replacement was easy, one screw under the rail of the ice enclosure, then it slides out. Swap the parts and reinstall.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Herndon, VA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this instruction helpful to you?
Thank you for voting!
Water dispenser not working
First I unpluged the frigerator, then I turned off the water. Then I removed the the black cover from the bottom back of the frig. The valves are located on the bottom right. Unscrew the bracket that is holding the two valves. I then removed the bottom valve from the bracket, unplug the electrical connections, and connect to the new valve.
To remove the water lines from the valves just move the white ring around on top of the valve and pull the line out and insert into the new one when ready. (the valves are the same colors) Do the same to the top valve, mount back to the bracket, then mount the bracket to the frig, hook up your water line to the valve, turn on the water and check for leaks, plug it in. Then put a glass under the water dispenser and try it out, it'll take a few seconds to get the water running through.
PartSelect was very quick on getting me my parts, TWO days, couldn't believe it. Very good examples of parts on web page.
Very satisfied and will use again.
To remove the water lines from the valves just move the white ring around on top of the valve and pull the line out and insert into the new one when ready. (the valves are the same colors) Do the same to the top valve, mount back to the bracket, then mount the bracket to the frig, hook up your water line to the valve, turn on the water and check for leaks, plug it in. Then put a glass under the water dispenser and try it out, it'll take a few seconds to get the water running through.
PartSelect was very quick on getting me my parts, TWO days, couldn't believe it. Very good examples of parts on web page.
Very satisfied and will use again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Betsy from Zimmerman, MN
- Parts Used:
- 12001892
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Wrench set
Valve Leaking
The valve on the frig cracked when the frig was in freezing temps during a move.
The part was slightly different than the picture on the parts website due to a design change that eliminated the Y in the water line created only one connection on the valve where there used to be two. I found this out reading on other websites.
This design change also resulted in a part number change, but because this website had such good pics and views, I was able to determine the part was right. We received the part within 3 days and installation was easy. We eliminated the Y in the line and attached the fittings.
The part was slightly different than the picture on the parts website due to a design change that eliminated the Y in the water line created only one connection on the valve where there used to be two. I found this out reading on other websites.
This design change also resulted in a part number change, but because this website had such good pics and views, I was able to determine the part was right. We received the part within 3 days and installation was easy. We eliminated the Y in the line and attached the fittings.
Was this instruction helpful to you?
Thank you for voting!
Ice wouldn't eject from ice dispenser
I removed the black drip grill and unscrewed the two screws holding the faceplate in place. After unplugging the faceplate from the dispensing unit, I removed the four remaining screws; be careful, one screw is shorter than the others.
I then pulled the dispensing unit away from the freezer door and removed the ice door assembly. WARNING: Make sure that you look carefully at the alignment of the return spring BEFORE you even touch it because as soon as I started using the needle-nose pliers to remove the spring, it shot across the room! Also, look carefully at how the end of the plastic rod fits over the old solenoid; in fact, look carefully at the entire plastic rod and how it aligns with everything!
Unfortunately, the pictures in the instructions are fuzzy so you can't really see how the spring is installed and how the plastic rod fits over the solenoid.
The solenoid was easy to remove and replace. Be aware that the plunger part of the solenoid slides in and out easily, so it's easy for it to fall out of the solenoid unit and roll away.
Once I had everything back where it was supposed to be, I screwed everything back in and the ice/water dispenser worked like new. I was even able to clean off some calcium deposits inside the unit while I had it opened.
If I have to do this again, I would estimate that it would only take 15-minutes or so. It took me longer because I didn't look at the alignment of the plastic rod in relation to all of the parts---that is one of the most important steps of this operation.
Anyone who is comfortable using tools and working with small parts should be able to complete this replacement project with minimal difficulty.
I then pulled the dispensing unit away from the freezer door and removed the ice door assembly. WARNING: Make sure that you look carefully at the alignment of the return spring BEFORE you even touch it because as soon as I started using the needle-nose pliers to remove the spring, it shot across the room! Also, look carefully at how the end of the plastic rod fits over the old solenoid; in fact, look carefully at the entire plastic rod and how it aligns with everything!
Unfortunately, the pictures in the instructions are fuzzy so you can't really see how the spring is installed and how the plastic rod fits over the solenoid.
The solenoid was easy to remove and replace. Be aware that the plunger part of the solenoid slides in and out easily, so it's easy for it to fall out of the solenoid unit and roll away.
Once I had everything back where it was supposed to be, I screwed everything back in and the ice/water dispenser worked like new. I was even able to clean off some calcium deposits inside the unit while I had it opened.
If I have to do this again, I would estimate that it would only take 15-minutes or so. It took me longer because I didn't look at the alignment of the plastic rod in relation to all of the parts---that is one of the most important steps of this operation.
Anyone who is comfortable using tools and working with small parts should be able to complete this replacement project with minimal difficulty.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Choctaw, OK
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Arlington, VA
- Parts Used:
- 12001991
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice shoot door broke and would not open or close
Removed the drip tray and cover panel. Then removed shoot housing, replaced broken door and reassembled in reverse order. Easy as pie.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- danny from adelanto, CA
- Parts Used:
- W10920279
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
fridge ouit cooling
where the wires crossed at the start relay, 20 years of vibration allowed them to short out and burn out the start relay ..since i have 2 identical fridges i switched the run capacitor to determine it was'nt bad too...ordered a start relay wednesday nite and got it friday morning...cold fridge by noon...good service and the part was exactly the same as the original....
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from SEBASTOPOL, CA
- Parts Used:
- 12001935
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
Icemaker fill tube cracked
The factory installed fill tube was formed and molded, hard plastic. Nothing like the replacement part or the one depicted in the install instructions.To remove it, I had to grip the exterior water tube module with a pair of Visegrip pliers, twist and pull as hard as possible, to expose a section of fill tube. I then had to cut through the tube with a hacksaw to remove the module and flange that secure it to the access hole. From the inside, I removed the ice maker and fan shield to expose the remaining section of fill tube. Using a section of copper pipe and a hammer, I was able to drive the tube through the back wall of the appliance. Fitting the new tube was easy. However, it is too short to reach the fill cup. I fashioned a section of the old tube to create an extension which I inserted in the new part. And, much to my surprise, it actually works!
Was this instruction helpful to you?
Thank you for voting!