Cathy from HOPATCONG, NJ
Parts Used:
W11384469
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
lawrence from TRAVERSE CITY, MI
Parts Used:
WPW10196393
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Noisy, running constantly motor in damper unit.
Unsnapped and pulled off small cover exsposing two phillips head screws. I removed larger cover and styrofoam insert fully exsposing the damper unit. i unplugged same and with a 1/2 inch wood chisel was able to release the "snaps" holding the old unit in place. Simply reverse procedure to install new unit.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from PHOENIX, AZ
Parts Used:
W11613295
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The refrigerator was working for just 1 minute and breaks, I discovered that the fan was not working , I understood that there wsa something wrong with the condenser fan motor. I just order a new one.
The installation video for condenser fan motor helped a lot to know how to disconnect the old fan motor and connect the new one. So easy just know how to remove and put back the fan gently, observe carefully where is the center and the connector position; 15 min after everything was done and the unit works well to date.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from JACKSON, MS
Parts Used:
WPW10503278
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The control indicators would flash and buzzing noise came from the controler
Followed the video exactly as shown from the website. I do suggest using a mirror or your phone to visualize the notch to press to drop the cover.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Lancaster, CA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from GLOVERSVILLE, NY
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carlton from CHICAGO, IL
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light out.
Popped out the old switch and replaced it with the one dying
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from WYNNEWOOD, PA
Parts Used:
WPW10671238
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Rail snapped
Followed video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from FORD CITY, PA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Freezer occasionally had a temperature alarm.Clicking noise also.
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jacob from SHEBOYGAN, WI
Parts Used:
WP67006877
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Old glass broke , new glass fit perfect
Just set the glass shelf onto frame perfect fit
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel F from CALEDONIA, MN
Parts Used:
W11613295
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer and refridgerator just stopped working.
The Condenser Fan Motor was already removed due to searching for the problem. The new fan motor looked different from the original but I felt very comfortable that Part Select had sent me the new part showing original part number changing numbers over the years. Simply placed the fan blades onto the new motor lined up 2 of the holes placed screws and tightened then plugged the wire ribbon into the Condensor Fan Motor, plugged in the Refridgerator and it worked beautifully.

The instruction video on the Part Select Web Site made it so incredibly easy to install. Installation took under 3 minutes!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from DEARBORN, MI
Parts Used:
WP67003637
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Our old plastic dairy door had a broken part and it kept coming undone
The new door just popped into place. Took seconds to complete. Fast delivery too.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from GOLDEN, CO
Parts Used:
WPW10503278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
About twicw per year the freezer would ice up because the control board didn't activate the defrost element
Removed the cover using a mirror to see how to release the clips on the rear side of the cover, removed the circuit board noting how everything was installed and also visually verified the part was the same. Broke the circuit at the designated score, installed and followed instructions for programming. All is well now.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nancy from LOUDON, TN
Parts Used:
WP67006877
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
broken glass shelf
Replaced shelf, very simple
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Meridian, ID
Parts Used:
WPW10503278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Lower freezer section was icing up, not defrosting properly. Repeated manual defrosting including disassembling did not solve the problem.
Emptied and disassembled the freezer. Defrosted and dried the coils. Tested the defrost heater coil ( 50 ohms ) PRT and fan - all OK. Opened the lower back panel and cleaned the water collection tray. Vacuumed out all debris including coils underneath. Reassembled everything. Removed the old control board and installed the new board paying attention to ESD steps. Applied AC power. Programmed the new board per the video link ( nicely done ). 3 weeks later and the unit seems dry and happy. Running at lower settings with good temperature results. Suspect the 24VDC relay activating the defrost heater coil on the control board or what controls the relay not working. May pull relay for test.
1 person found this instruction helpful.