Customer:
Eric from NEW YORK, NY
Parts Used:
WR02X10520
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Noisy refrigerator
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Cutler Bay, FL
Parts Used:
WR60X10220
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Refrigerator
The hard part was cleaning the dust around the coil and fan area. Its plug and play right after that. Two nuts on the fan housing and a wire harness snaps on and off. Bam! 1,2,3 Up and running. . Like new. . . Thank you ps
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
adam from folsom, CA
Parts Used:
WR60X10257
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
fridge was cool not cold, ice cream in freezer wasn't hard
removed ice maker, back panel and two additional plastic trim pices to get to fan. Single molex connection for the wires. I got the part the next day. Wasn't expecting part for three to five days. Very impressed!
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Keller, TX
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GERALD from MORRISON, CO
Parts Used:
WR50X10071, WR60X10205, WR02X12149, WR17X11511, WR9X565
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Frig Box Freezing - Freezer Turning Into An Oven
In freezer box removed shelf, removed 2 screws from back panel, removed 3 plastic covers (1 with 2 screws, other 2 snaped out. Unsnaped defrost thermostat from copper tube then cut 2 wires (yellow & orange) stripped all wires back a little then used 2 wire nuts to reconnect the new thermostat and resnapped back onto the copper tube. Removed 4 screws from evaporator fan housing (original one warped from overheat and caused fan blade to get chewed up) unpluged fan motor wiring and removed ground wire and motor from warped housing, removed fan plade by just pulling on it. Installed new fan blade by pushing it on the fan motor shaft, reinstalled the fan to the housing and the housing into the freezer box. In the frig box I removed the control panel from top of the box by removing 4 screws and unpluging the main wiring plug and the defroster control then reinstalled it all in reverse order. Also had to renew the stick on foam on the evap fan housing. Over all it was an easy task.
9 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chip from Mandeville, LA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Curtis from Dothan, AL
Parts Used:
WR60X10207, WR02X12149, WR02X10098
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
A rat had chewed half of all four blades off
First I removed the left condensor fan motor bracket nut, loosened the right motor bracket, dropped the moter bracket down freeing the motor from the rubber grommets.
Pulled the fan off from the motor shaft, pressed the new fan on the shaft and installed new grommets. Replaced the motor bracket and tightened the right bracket nut and checked fan for clearance and free spin. Reinstaled the left bracket nut. Turned on the refrigerator and checked fan for action. Everything worked great.
I did not know the fan replacement came with a compression ring already installed, so now I have an extra compression ring.
9 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Betty from Downers Grove, IL
Parts Used:
WR30X10154
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Ice bucket cracked
We have an older model refrigerator and thought it would be impossible to find a replacement ice bucket for the freezer. Not only did you have the exact part but it came unbelieveably fast. I would use your website again!
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Folsom, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
8 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from San Marcos, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from Red Bluff, CA
Parts Used:
WR60X10257
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Insufficient cooling
Like the other repair story I read about this part, the fridge was cool not cold (58* instead of an ideal 38*), and my ice cream stayed soft in the freezer. I removed the pannels in the freezer with a small socket wrench to find the fan burnt out. When the motor came, all I had to do was move the fan blade and gromets to the new motor. Closed it into the brackets and remounted it to the freezer. The part cost less here than at the factory web site and the fridge works great. Thank you PartSelect.com!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerold from Rocklin, CA
Parts Used:
WR60X10220
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
bad condenser fan motor, noisy
used prior reviews, was good, I was not sure how to remove fan blade. It just pulls off.
space is tight but every thing went ok.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Broomfield, CO
Parts Used:
WR60X10205
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
The original fan had its blades sheared by ice build-up
The original design is poor. The evaporator fan is mounted in an upright position just below the ice-maker. A plastic grate mounts over the fan assembly to allow for air circulation. Unfortunately, random chips of ice from the ice maker can fall into the fan, causing the fan to shear its blades. Replacement of the fan blade is relatively simple (accept for having to completely unload the freezer and remove all back covers, the ice-maker auger motor assembly, and the metal evaporator cover). In order to mimimze this from reoccuring, I installed a 1/4'' mesh metal screen over the exhaust ports on the cover. Thus far, this has worked well to keep ice chips out of the evaporator fan.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from BENSALEM, PA
Parts Used:
WR60X10220, WR60X10207, WR02X10098
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Noise from Condensor Fan and Fan Motor.
I watched the video provided by PartSelect twice, then proceeded with the removal and installation. It took me 40 minutes from start to finish. Piece of Cake. Everything works fine now.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from SCOTTSDALE, AZ
Parts Used:
WR55X10025
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.