Models > CST20KABEAD > Instructions

CST20KABEAD Hotpoint Refrigerator - Instructions

Jump to:

All Instructions for the CST20KABEAD
46 - 60 of 432
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Catherine from SEATTLE, WA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.

No tools needed, the cap is just held in place with pressure from the wire.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Point Pleasant, NJ
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Freezer iced up, no air circulation
Removed the back panel of the freezer to inspect. The coils were totally iced up. Proceeeded to defrost coils with a heat gun. I then removed the defrost element to insepct and meter reading showed as open (infinite resistance). I ordered a replacement element and it arrive 2 days later. Replace the element and everything worked OK except for the ice maker. It seem that moisture had frozen on the motor impeller for the auger drive motor and locked it up. I removed the drive assembly and defrosted the motor impeller to free it. Everthing now is working fine.
Your blow up drawings made this a very easy repair
Thanks
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randall from Sterling Hts, MI
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
unit was not cooling, evaporator was iced over
This is the third time the defrost heater has failed, the part was shipped prompt, and the replacement was upgraded to a dual coil. The repair was quick and more cost effective than having a repair guy come out .
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Middleville, MI
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
refrigerator not cold
I called the repair tech who obviously did not want to come out, thank god. He told me to remove the back panel of the freezer and also check fan on back side. Told him there was alot of ice on freezer condenser and he advised that defrost heater was probably shot, and referred me to partselect.com. I unplugged the frig/freezerer, and removed the heater and saw it was blackened and cooked. I used a hairdryer to thaw the condenser, and the new part arrived the next day. I reattached the 2 plugs, 2 screws, and put the back panel of the freezer back on. I plugged the appliance back in, checked it 6 hours later and the frig is cold again. It was a VERY easy repair and took less than 30 minutes from start to finish. I was quoted between $40-$78 for the part at 3 different places in the phone book, which would have also required a 45 minute drive. I got it here for $38 including shipping and it arrived in 24 hours !
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GARY from SPRAGGS, PA
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ran All The Time Did Not Freeze.
Removed cover in freezer over evaporator,unbolted element ,plugged ,and replaced, very simple. Should be first thing checked when theres a problem.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Longs, SC
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Freezer building up Ice
This is such an easy fix!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Allen from Schenectady, NY
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.

Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ronald from palmyra, VA
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
freezer freezing and fresh food compartment not cooling
i unplugged the fridge, first i removed the racks, then unhooked the grounding clip. the i tool off two 1/4 nut screws holding the backplate. then i used my wifes hair dryer to thaw out the ice. after it thawed out i unscrewed the element bracket which is secured by two philips screw. after taking the screws off, its just unplug one end at a time and plug it to the new one to avoid confusion. then reverse install to put back together.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sandy from Greenwood, SC
Parts Used:
WR72X10010, WR72X10009
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
the slide rail on the top drawer broke in half
I took the glass plate off the top of the drawer, then removed the draw. I then removed the two screws holding the slide rail. I put the new slide rail in place, put the screws back in it, slide the drawer back in place and replaced the glass top. nothing to it.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Sarasota, FL
Parts Used:
WR51X10101
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marc from Hollywood, FL
Parts Used:
WR71X2373
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Needed a new door module
Fit perfectly, took 2 seconds to install.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
josh from springfield, OR
Parts Used:
WR72X10010, WR72X10009, WR72X10008, WR72X10007
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
drawer rails broken
installed 3 of 4 shipped parts. ended up with 2 upper right hand slide rails, even though ones package said upper left.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gregory from Glen Rock, PA
Parts Used:
WR13X10020
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Door would not shut
Really simple, I used a can of soup and a small piece of wood set under the door, and tapped it tight with the hammer to hold it in place while I removed the hinge. Two bolts at the bottom and two under the door itself. Installed the new hinge set, bolted tight and removed the shim.
The whole thing took less than 5 minutes
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Paulden, AZ
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Refrigerator and freezer stopped cooling and began to thaw.
The repair is pretty straight forward it is the preparation that takes time.
The food in the freezer portion of our side by side began thawing. We tried adjusting the temperature level to colder but to no avail. When we started emptying the freezer compartment I noticed a large amount of frost/ice at the back.
I turned the control to off and began defrosting the freezer using my wife's hair dryer. :) Once the outside layer was defrosted I removed the panel covering the coils. They were packed solid with ice and took over 30 minutes to defrost. Be sure to use a pan or container to catch some of the water because the catch pan under the refrigerator isn't large enough.
Once everything was defrosted I removed the heater tube assembly (at bottom of coils)it was a glass tube with a coiled wire element inside. The element had shorted out and the tube appeared black in that area.
I replaced this single tube heater with the double tube recommend on the partselect.com site. This required re-routing one of the wires and splicing in the plug/wire assembly contained in the repair kit.
Simply followed the instructions, reassembled everything and turned the control back on. No more problems. A very easy repair for anyone mechanically inclined and who owns a few basic tools.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Waltham, MA
Parts Used:
WR13X10020
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Wrench set
Cam riser washers broken
Easy repair. No need to remove the door. Simply prop up the door with blocks or books - remove hinge and riser assembly - replace with new parts. Total repair time about 15 minutes. Tools needed only an open end wrench.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CST20KABEAD
46 - 60 of 432