Customer:
Erold from Alamosa, CO
Parts Used:
WR50X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
frosting over and freezer not cold enough and not circulating cold air .
Defrosted the refrigerator,power off and cut the 2 wires on thermostat and sodered the new one on and shrink tube sealed the wires,refrigerator works like new!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ken from Chapel Hill, NC
Parts Used:
WR60X10172, WR50X10025
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Socket set
Refrigerator section too warm
I followed advice from other posts on this web site. The only thing additional I'd recommend is to take pictures of assemblies before you disassemble them. A neighbor gave me that useful tip. It should be noted that I first noticed my refrigerator failure back on June 22, 2012. I hired a reputable local repair service to fix it. They replaced the Defrost heater (item 618) and charged me $ 208.14. Then on August 22nd, I noticed that the problem resurfaced. I decided to fix it myself using info from site. The repair went well, and I'm hopeful that it will stay repaired. Kudos to this site!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leroy Neal from Andrews, SC
Parts Used:
WR50X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
refrig.not cooling.freezer ok.
removed freezer panel,found the evap.iced up,put defrost timer into defrost. wated five min.no heat used hair dryer to defrost evap.found termination visually defective.replace defective part.no call back.Iam a EPA certified universal technician.
Was this instruction helpful to you?
Thank you for voting!
Customer:
STOYAN from ARLINGTON HEIGHTS, IL
Parts Used:
WR50X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
a lot of ice in the freezer-and in the refrigerator is warm
HI I am Stoyan. I had a problem with my refrigerator. The freezer produces a lot of ice, but the refrigerator was warm. I try to find what other people comment on this site partselect.com. I decided that the thermostat is damaged. I ordered the thermostat from partselect.com and I had the delivery within 24 h. and I was very happy with the fast delivery service .I saw a video on the same site how they show how to do myself the change of the thermostat. I took the hairdryer from my wife to defrost the refrigerator for 40 minutes and removed the old thermostat. I decided to test the heater with a 9 volts electricity from a portable charger for a car. I made an electric circuit chain and on the end of the heater I saw that there was 9 volts electricity and I understood they are ok. I changed the thermostat for 5 minutes, looking very carefully to match the colors of the cables. For $ 11, I saved money to buy a new refrigerator or pay a big bill to a repair service. Thank you for the video that helped me very much. My refrigerator work well.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paul from east hanover, NJ
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
refig light did not work
per your instructions
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jules from Crowley, LA
Parts Used:
WR23X37285
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
failed light switch
I started removing the switch by prying on the right side with a screwdriver, when it emerged enough I used pliers to finish removing it. I then unpluged rhe wires from the bad switch and pluged them on the new switch and "poped" it into the hole.
Was this instruction helpful to you?
Thank you for voting!
Customer:
christopher from collegeville, PA
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
no light in freezer
Connected the 2 wires and pushed in the switch until it clicked.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from District Heights, MD
Parts Used:
WR60X10172
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Noisy evap fan motor
Simply unplug fridge, remove air duct mounted on rear panel, release panel itself, pull fan blade off, disconnect grounding wire, detach fan motor bracket, disconnect wire harness to release fan motor, install new fan motor and reconnect, secure with bracket, reconnect grounding wire, reposition fan blade onto motor shaft, reinstall rear panel and secure screws. Remount air duct and plug appliance back in. This is the second motor that was replaced since 2002. The 1st motor dies after 5-6 years.