Models > CSX19LABGWH > Instructions

CSX19LABGWH Hotpoint Refrigerator - Instructions

Jump to:

All Instructions for the CSX19LABGWH
121 - 135 of 433
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
William from Raytown, MO
Parts Used:
WR51X10031
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Would not defrost
Removed the internal cover and used a hair drier to defrost the evaporator. Unpluged the conectorto the harnes. Placed new part in and pluged it in, replaced cover and tested.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Port Saint Lucie, FL
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
freezer is working but refrigerator is not cooling
remove screws in back panel and remove , defrost coils wit hair dryer,remove two screws that hold defrost heater unplug wire's.plug in new heater put screws back in ,put panel and screws in ...done
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from New Smyrna Beach, FL
Parts Used:
WR02X10140
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The part arrived very fast, I had read other posts about emptying the door etc so that all made it go really fast. I changed the part out in about 10 min. but the shelf removal etc all added up to about 20 - 25 min.
Remove the hinge cap on top, the loosen the bolts, remove the hinge. Pick up the door from the lower hinge, lay it down and place the cam riser on the lower hinge. Replace the door, install the top hinge and check the alignment and you are done.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from north Bellmore, NY
Parts Used:
WR51X10031
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
The Fridge Was Not Defrosting
The repair stories for this part are helpfull. The only problem I came accross was figuring out which part I needed to order. The parts diagram only showed one part labled 230, but when I used the drop down box to order the part there were 2 parts labled 230 for 2 diffrent prices. I called ge customer care and found out the less expencive part listed as 230 does not come with the wires etc. . The more expensive piece has the wire harness and every thing needed. I went with the more expensive part and it was a snap to install. . . .
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Russell H. from Rocky Mount, NC
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice frozen on unit so air could not flow to refrigerator side
Take off the panel in the freezer side to expose the heater, defrost all the ice. Remove the screws that hold the heater in place and remove the wires from each end. Plug in the new unit and replace screws. Replace screws in the freezer panel, to complete the instulation. It will take the most time to defrost the ice, and clean up the water. To help defroct I used my wifes hair dryer. (She did not know it)
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Manuel from Miramar, FL
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
heater element broken
Disconnect the broken one and install the new one
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Triem from Ballwin, MO
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Water come out from the bottom of the freezer's door. The temperature was warmer in the fresh food area. The products in the freezer become soften. When transfering the products to the another freezer , I've noticed that the ice was build up on the panel that cover the evaporator coil.
Removed the evaporator panel's cover. The ice covers up the defrost heater. Use heat gun to melt the ice on the defrost heater then removed the 2 screws, pull it out and check its resistance (it was open). After replaced the deforst heater, the refrig. works OK.
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from bayville, NY
Parts Used:
WR02X10140
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
cam britle door down to metal
remove plastic top hinge cover then twoscrews holding door with door closed it rested against freezer door then lefted off door put on flat surface remove tow screws at bottom of door installed new cam
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lorrie from Russellville, AR
Parts Used:
WR13X10020
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
Door dropped. Cam riser was gone
Emptied the refrigerator door so it was easier to take off. Used a screwdriver to remove the screw on the top hinge. Lifted door off bottom hinge. Laid the door down so I could take the bottom hinge off. Removed worn out parts and placed the new one on. Slipped door back on hinge,made sure it would close properly and was lined up with freeze door. Put top hinge back in place. Done!! Now door finally shuts on its own again!!! EASY!!!
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roscoe G from ROCHESTER, NY
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Lake Elmo, MN
Parts Used:
WR51X10101
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Frigerator side did not cool
1 Unplugged Refrigerator and removed all the freezer shelves.
2. Removed the light bulb in the back of the freezer.
3. Removed rear panel on back wall of freezer. I had to do some defrosting on the back panel due to frost build-up.
4. Defrosted cooling coils using a hair dryer. This took a considerable amount of time due to frost build-up. Also, there was a considerable amount of water run off due to melting. I plugged the drain, and used towels and a bucket to soak up the water.
5. Removed the old element located at the bottom of the cooling coils and removed the wires from each end.. At that time, I also notice when the directions referred to "right" and "left", the point of reference was from looking out of the unit (not facing the unit).
6. Reroute the pink wire on the left side to the right side of the freezer coil. The defrost heater element I removed was a single heating element and the element I purchased was a double heating element. I then attached the blue and pink wires to the right side of the heating unit. (The pink wire was sufficiently long to reach the element. I did not need to splice an extension into it). The yellow "jump" wire was on the left side of the heating unit.
7. Attached the new heater to the freezer coil framing with the two screws.
8. Reinstalled the back freezer panel.
9. Reinstalled the freezer shelves.
10. I plugged in the unit to restart the refrigerator.

The defrosting took a considerage amount of time. Otherwise would have taken about 30-45 minutes.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Shannon, IL
Parts Used:
WR51X10031
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Old wires wouldn't come out.
First of all I'm 76 years old. The same thing happened 5 years before and I had a service man out to fix it. I did what he did. Unplug the heater from the harness and plug in the new heated.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Zhongjiang from League City, TX
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
Bad Defrost heater caused ice built up on evaporator, freezer not cooling enough
1. Opened rear panel of freezer, exposed the evaporator which covered with ice. Using warm water to melt down the ice, and found the bad heater.Reinstall the rear panel, the referigerator working again, without the heater.
2. Ordered the defrost heater from you.
3. 4days later, the heater assembly arrived. I opened the rear panel of freezer again, replaced the heater. The problem fixed.
This is the second time to replace the heater assembly. GE stuff looks like not very good quality.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
eric from georgetown, DE
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Freezer iceing up & freezer tempature dropping
I had the refridgerator given to me by a friend who was tired of defrosting it. I took the cover off of the inside of freezer to expose evaporator and found defroster heater was bad. I replaced the heater , the unit works great , now i have approximately fifety dollars into a refridgerator that sells for about a thousand
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Colville, WA
Parts Used:
WR02X10140
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Wrench set
Broken Cam
1. Blocked up the door keep it steadily and enable ease access to screws.
2. Removed screws holding the door closing cam and lower door attach bracket.
3. Disconnected clamp holding the water supply line for the water and ice dispenser and disconnected the water line at the joint.
4. Removed the broken cam and put the new one in it's place, threading the water supply line through the hole of the cam.
5. Put everything back together in reverse sequence of removal.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CSX19LABGWH