CSX19LABGWH Hotpoint Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Itamar from SARASOTA, FL
- Parts Used:
- WR02X10140
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Replacing the Hinge Cam Riser (GE Part # WR02X10140) - it was brooken
I have just followed the instructions on the youtube video: It is really easy. I did. Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pap's Sport Shop from Webster Springs, WV
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Defroster unit went out
First let me remind you my husband is disabled so it was up to me to do the repair. I'm 70 yrs old. I first removed everything from freezer and then removed the back cover removimg 4 screws,then i removed the old defrost unit which held 2 screws replaced with the new one then i had to put cover back in place..then put everything back in freezer and so far its working...Only time will tell.But the part was so reasonable that if if i have to i will get another..but not for a while i'm hoping,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Sarasota, FL
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Open defrost heater
The most difficult part of the repair was the melting of the ice and preparation. I did change a single element heater for a dual element heater, which required a little manual flexing of the sub-frame, but it assembled with little issue. I was lucky, I did not have to splice the extended harness connection. Rerouting my existing gave sufficent length.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Not sure if the single elements were changed for dual, but it did have the same PN as the unit I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Longs, SC
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Freezer building up Ice
This is such an easy fix!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
1-Unplugging the fridge and emptyi it. Remove all shelves.
2-remove the 2 screws at the top of the back panel with a 1/4 inch nutdriver. You'll have to tilt ithis panel forward and sideways to get it out.
3- DO NOT CHIP AT THR ICE COVERING THE COOLING COILS? Replace one shelf and rest a hair dryer on low heat on the shelf.. Plug the drain hole at the bottom with a rag so all the melted ice water doesn't flood the floor under the fridge. Soak up the water with a rag and bucket- this should take 20-30 minutes.
4-Remove the red and blue power cables from the element. Only 2 philips head screws hold the defrosting element in place. Once it's out you can tell it's burned out because it looks black like a burned out lightbulb.
4-Plug in the red and blue power cables to the new unit. You will need to reroute the blue power cable because the new unit has both power connections on the same end.
5-Replace the cover panel by sliding it in at an angle and replace the 1/4 inch screws.
6-Replace the shelves and plug in the fridge.
That's it!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marc from Hollywood, FL
- Parts Used:
- WR71X2373
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Needed a new door module
Fit perfectly, took 2 seconds to install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Middleville, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
refrigerator not cold
I called the repair tech who obviously did not want to come out, thank god. He told me to remove the back panel of the freezer and also check fan on back side. Told him there was alot of ice on freezer condenser and he advised that defrost heater was probably shot, and referred me to partselect.com. I unplugged the frig/freezerer, and removed the heater and saw it was blackened and cooked. I used a hairdryer to thaw the condenser, and the new part arrived the next day. I reattached the 2 plugs, 2 screws, and put the back panel of the freezer back on. I plugged the appliance back in, checked it 6 hours later and the frig is cold again. It was a VERY easy repair and took less than 30 minutes from start to finish. I was quoted between $40-$78 for the part at 3 different places in the phone book, which would have also required a 45 minute drive. I got it here for $38 including shipping and it arrived in 24 hours !
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
With the "blow-up view" appliance feature on this web-site, and simply being guided to the correct part by entering the model number, it was a very easy ordering process and repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sandy from Greenwood, SC
- Parts Used:
- WR72X10010, WR72X10009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
the slide rail on the top drawer broke in half
I took the glass plate off the top of the drawer, then removed the draw. I then removed the two screws holding the slide rail. I put the new slide rail in place, put the screws back in it, slide the drawer back in place and replaced the glass top. nothing to it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ronald from palmyra, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
freezer freezing and fresh food compartment not cooling
i unplugged the fridge, first i removed the racks, then unhooked the grounding clip. the i tool off two 1/4 nut screws holding the backplate. then i used my wifes hair dryer to thaw out the ice. after it thawed out i unscrewed the element bracket which is secured by two philips screw. after taking the screws off, its just unplug one end at a time and plug it to the new one to avoid confusion. then reverse install to put back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from SPRAGGS, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ran All The Time Did Not Freeze.
Removed cover in freezer over evaporator,unbolted element ,plugged ,and replaced, very simple. Should be first thing checked when theres a problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Schenectady, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
No Defrost - Top of freezer thawing
By the time this failure (failed defroster heating element) is evident (top of freezer starts thawing), the entire freezer coil is encased in a block of ice & frost is visble on the back freezer panel.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Empty the freezer & unplug (or turn circuit breaker off) then remove all racks and the light bulb then remove the two lower drawer guides using a phillips srewdriver (2 scrwes each). Use a 1/4" nutdriver to remove the two panel screws on either side of the light bulb socket and pull the panel out, unclip the green grounging wire and set panel aside. this exposes the freezer evaporator coil which is probably encased in ice. If so, use a heat gun or hair dryer to melt the ice away. This takes a half hour of heat application and a bowl or other catchpan should be placed under the coil to remove some of the resulting melting runoff so the evap. pan under the fridg/freezer unit won't be overwhelmed with the excess water.
Replacing the defrost heater & bracket assembly itself is just a matter of removing two phillips screws on either side of the bracket assembly, pulling the bracket free and then uncliping the two electrical terminals. Clip in the new unit to the eletrical terminals & replace the screws, reinstall the rear panel (don't forget to reconnect the ground wire), install the drawer backets, light bulb, shelves and drawer & reapply power. Replacing the bracket itself w/o the defrost proceedure takes about 15 minutes.
Note: If this symptom occurs and is diagnosed (the heater tube will be black and electrically read as "open" using an ohmmeter) and you cannot get the heater assembly & bracket assembly immediately, you can use the heat gun (hairdryer) manual defrost proceedure noted above to get the the unit running while you await the parts arrival. I used the manual defrost procedure and there was just some moderate frost on the coils after five days when I was able to install the replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Lockport, IL
- Parts Used:
- WR13X10020
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Old hinge washer worn out.
First I placed a 2x4 under the frig door to keep it in place while I removed the hinge on the bottom of the door. I removed two screws holding the hinge and one screw holding the washer in place. I also loosened a screw adjacent to the washer so that I could more easily remove and replace the washer. The parts went in easily. The repair took much less time than I anticipated.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daylyn from Houston, TX
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator not cooling // freezer running non-stop
Fortunately while my refirgerator was still under warrant I had this same problem and watched the repairman fix it. To confrm my suspicions I cleaned out the freezer compartment, removed the back panel (2 screws), and used a hair dryer to defrost it. I suggest plugging the drain hole or laying a towel in the bottom of the compartment to catch the run off or your drain pan could over low. Once defrosted I was able to verify that the element on the defrost heater was burnt. Since it was Sunday I re-assembled and cranked it back up until I could get the part. I did a goggle search on Monday, found the part instantly using only the model number from the refrigerator at PartsSelect.com. The part arrived Wednesday as promised, I repeated the process from Sunday, removed the defective part (2 screws & 2 plug in type wire connections) and she works like a charm now. I do think the manufacture of the part should consider a new design since this is the second one my unit has needed in less than 5 years. At only $27.50 ea. I should have purchased a spare to have for the next time!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Castle Hayne, NC
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
Fridge Warm, Heavy Frost on Freezer Back
Well, first I googled the problem and the model and found my way pretty quick to you guys. I sent a note to Tom P., who confirmed that I was looking at the right things. Then I offloaded everything from the freezer and fridge to the RV fridge and chest freezer, unplugged it and used my hair dryer to melt the ice on back plate so I could remove it.
I removed the two small screws at the top of the back, below the icemaker and light bulb, and slid the back cover up and out. Since my coils were pretty heavily iced, it took about half an hour to melt enough that I could get the defrost heater out and check it for continuity, which it failed.
The replacement design is slightly different (2 heater coils vs 1 and connectors on one end), but functionally the same. When putting the new one in, you need to re-run the blue wire down the same side as the pink wire because the connectors are on one end. Mine was long enough to work, but they include a splice kit in case yours isn't.
It took me longer to get the cover back on than to replace the heater assembly! Everything is back to normal, had ice cubes within a couple of hours...
Thanks for your help!
I removed the two small screws at the top of the back, below the icemaker and light bulb, and slid the back cover up and out. Since my coils were pretty heavily iced, it took about half an hour to melt enough that I could get the defrost heater out and check it for continuity, which it failed.
The replacement design is slightly different (2 heater coils vs 1 and connectors on one end), but functionally the same. When putting the new one in, you need to re-run the blue wire down the same side as the pink wire because the connectors are on one end. Mine was long enough to work, but they include a splice kit in case yours isn't.
It took me longer to get the cover back on than to replace the heater assembly! Everything is back to normal, had ice cubes within a couple of hours...
Thanks for your help!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Julio from Brea, CA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
The freezer section was not working and the cooling increased in the bottom side of the fresh food section.
I had this problem before and I knew it was related to the heater located in the freezer section. With the help of the drawings in the parts selct webpage I was able to identify the part I needed within 5 minutes. I ordered the part abd in 3 days I had it delivered.
I followed the instructions that came with the part step by step and I got my refrigerator up mand running in about 45 minutes.
I followed the instructions that came with the part step by step and I got my refrigerator up mand running in about 45 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Kingman, AZ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrigerator and freezer not getting cold enough.
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires..
Was this instruction helpful to you?
Thank you for voting!